Inspections for the day of: Monday, July 20, 2020.
Number of inspections: 28
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-02922 Rough-in7/20/20207/20/20207/20/2020 2:17:42 PMPPASS
Add p test Phone #: ###-#### Inspection requested via web by Joe Taylor- R/I ok- corrections made
MEC20-02922 Pressure Test7/20/20207/20/20207/20/2020 2:17:18 PMPPASS
Add rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- 20lb gas pass tagged meter location
MEC20-02969 Rough-in7/20/20207/20/20207/20/2020 1:47:09 PMPCANC
Grid Inspection for duct work extension/ modification - please contact Shawn @ ###-#### Phone #: ###-#### Inspection requested via web by Amanda Casper- bld needs issued under review and mechanical permit needs attached to bld- talked to Shawn about this by phone will reschedule per phone conversation
MEC20-02846 Pressure Test7/17/20207/20/20207/20/2020 1:24:47 PMPNR
Mechanical rough in with gas pressure test Phone #: ###-#### Inspection requested via web by Chris Gonzalez
MEC20-02846 Rough-in7/17/20207/20/20207/20/2020 1:24:35 PMPNR
Mechanical rough in with gas pressure test Phone #: ###-#### Inspection requested via web by Chris Gonzalez
MEC20-02831 DOC - Permit Finaled7/20/20207/20/20207/20/2020 1:23:50 PMPPASS
pics sent via text- final ok
MEC20-02844 Pressure Test7/20/20207/20/20207/20/2020 1:22:39 PMPFAIL
gauge wont zero out on 20lb test- 5lb flue pass- need city approved man j onsite
MEC20-02844 Rough-in7/17/20207/20/20207/20/2020 1:21:31 PMPPART
Phone #: ###-#### Inspection requested via web by Chris Gonzalez- ducting in garage above in joist ok- ok for sheetrock above furnace only ok
MEC20-02831 Final7/17/20207/20/20207/20/2020 12:42:29 PMPFAIL
Please call Nancy on your way. - ###-####
She will open the garage for access to the coil and the AC.
Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c locking caps ok- due to COVID 19 we can not enter into occupied homes until further notice- please send pics of coil in home and co detector
MEC19-03677 Final7/17/20207/20/20207/20/2020 11:06:29 AMAPASS
AC: 4343 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok
MEC20-01485 Rough-in7/16/20207/20/20207/20/2020 10:30:09 AMAPASS
duct seal inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- seal on all duct ok whole building- David will take pics of insulation above soffits- ok to cover soffits- ok for ceiling grid to install
MEC20-02959 Final7/20/20207/20/20207/20/2020 9:46:45 AMAPASS
final ok
MEC20-02959 Pressure Test7/17/20207/20/20207/20/2020 9:46:12 AMAPASS
Please call John first before arriving to make sure he is ready. ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg- 20lb gas pass- pics of install provided by installer onsite- co installed
MEC20-02844 Pressure Test7/17/20207/20/20207/20/2020 9:38:31 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Chris Gonzalez Inspection cancelled from web by: Chris Gonzalez
MEC20-02796 Final7/17/20207/20/20207/20/2020 9:32:23 AMPCANC
PRESSURE TEST Phone #: ###-#### >> Inspection requested via web by RM Mechanical Inspection cancelled from web by: RM Mechanical
MEC20-02952 Pressure Test7/17/20207/20/20207/20/2020 9:22:12 AMAFAIL
Gas pressure. Gauge outside. Just did gas line so it is a final as well. Door bell does not work. Phone #: ###-#### Inspection requested via web by Mary LaFayette-not holding pressure- gas gauge at 4 psi- please provide pics of gas line install to fireplace and dryer for final- might need combustion air up high in laundry room please verify and provide pic if in room with door
MEC20-02898 Final7/17/20207/20/20207/20/2020 9:15:23 AMAFAIL
Homeowner Jim Wheeler ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil locking caps ok- homeowner said no CO detector was installed- please verify and send pic for reinspect
MEC20-00751 Final7/18/20207/20/20207/20/2020 8:43:18 AMAFAIL
Phone #: ###-#### Inspection requested via web by Rubin Chervak- need lineset penetration outside sealed and completed- need pwoer to microwave on to verify flappers work
MEC20-00752 Final7/18/20207/20/20207/20/2020 8:42:22 AMAFAIL
Phone #: ###-#### Inspection requested via web by Rubin Chervak- need lineset penetration outside sealed and completed- need microwave power on to verify flapper works
MEC20-00753 Final7/18/20207/20/20207/20/2020 8:41:31 AMAFAIL
Phone #: ###-#### Inspection requested via web by Rubin Chervak- need lineset penetration outside sealed- microwave needs power turned on to verify flapper works looks like painted shut
MEC20-00754 Final7/18/20207/20/20207/20/2020 8:40:26 AMAFAIL
Phone #: ###-#### Inspection requested via web by Rubin Chervak- need lineset penetration outsie sealed- need microwave power on to check existing flapper
MEC20-02938 DOC - Permit Finaled7/20/20207/20/20207/20/2020 8:22:00 AMAPASS
final ok- pic sent via text for correction
MEC19-05622 Mec-Aging Inspection7/20/20207/20/20207/20/2020 7:50:15 AM FAIL
contractor needs to schedule inspection- has not been active since issued- permit will expire next aging if no activity
MEC19-02924 Mec-Aging Inspection7/20/20207/20/20207/20/2020 7:49:10 AM FAIL
contractor needs to have low pressure test witnessed to firepit- this gas line was covered up without inspection- schedule test or request extension if works ongoing- permit will expire next aging if no activity
MEC19-05623 Mec-Aging Inspection7/20/20207/20/20207/20/2020 7:47:16 AM PASS
should have been finaled on pressure test
MEC19-05623 Final7/20/20207/20/20207/20/2020 7:45:48 AMAPASS
final ok
MEC19-04329 Mec-Aging Inspection7/20/20207/20/20207/20/2020 7:44:39 AM CANC
permit expired
MEC19-04329 DOC - Permit Expired7/20/20207/20/20207/20/2020 7:44:27 AMAPASS
permit expired- no activity