Inspections for the day of: Monday, July 21, 2008.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02007 Electrical Rough-In7/21/20087/21/20087/21/2008 3:58:07 PMPPASS
shawn Note:please call 1/2 hr prior to inspection Phone #: ###-#### ric ok, no esc this project
ELE08-01989 Permanent Service7/21/20087/21/20087/21/2008 3:04:28 PMPPASS
kieth Phone #: ###-#### p/s o/h rec ok, will call for final, no esc this project
ELE08-01508 Electrical Rough-In7/20/20087/21/20087/21/2008 2:49:58 PMPPART
This is for the last 1st floor hard lids which are the lobby and electrical room. Also the General wants a consoltation for a 1st floor grid cover inspection borders only. Phone #: ###-#### Internet Inspection Request from: Don Lustig lobby hard lid, borders 1st floor only ok- will leave open if boxes and coordinate with electrician where working on heaters, no esc this project
ELE08-02010 Permanent Service7/21/20087/21/20087/21/2008 1:30:34 PMPFAIL
darrell Note: sp 69 Phone #: ###-#### called contractor, left correction notice, NEC 352.30(A) pvc shall be secured within 3' of panel,312.5 conductors entering enclosure shall have abrasion protection, 250.94 shall provide intersystem bonding termination at service and additional building, no esc for this project
ELE08-00642 Electrical Rough-In7/21/20087/21/20087/21/2008 12:40:08 PMPPASS
pat Phone #: ###-#### ok to cover garage only, no esc this project
ELE08-01511 Final7/18/20087/21/20087/21/2008 10:23:45 AMACANC
Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack called contractor, he wants to reschedule, no esc this project
ELE08-02000 Permanent Service7/18/20087/21/20087/21/2008 10:17:23 AMAFAIL
glen Phone #: ###-#### Note: please call 1/2 hr prior to inspection to meet with met contractor, nec 250.94 shall provide intersystem bonding connector, and water pipe ground, will recall, no esc this project
ELE08-02000 Final7/18/20087/21/20087/21/2008 10:16:17 AMAFAIL
glen Phone #: ###-#### see p/s, no es this project
ELE08-02001 Rough-In Permanent Service7/18/20087/21/20087/21/2008 9:31:01 AMADONE
Phone #: ###-#### Internet Inspection Request from: Bob Glenn inspection done 7-18-08
ELE08-00306 Electrical Rough-In7/21/20087/21/20087/21/2008 9:24:36 AMAPASS
Scheduled by a contractor via Hello! on 7/21/2008 at 6:45:26 AM. Contact: ###-####., walls only ok to cover, no esc this project
ELE08-00307 Electrical Rough-In7/21/20087/21/20087/21/2008 9:09:00 AMAPASS
Scheduled by a contractor via Hello! on 7/21/2008 at 6:44:01 AM. Contact: ###-####. called, walls only ok to cover, no esc this project
ELE08-01998 Electrical Rough-In7/18/20087/21/20087/21/2008 8:39:44 AMAPART
Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA called, left message, left correction notice, BCC all underground shall be inspected before cover, NEC 250.94 intersystem bonding termination shall be provided at service and additional building, 300.5(D)(4) shall use schedule 80 pvc where emerging from grade
ELE08-01507 Final7/20/20087/21/20087/21/2008 8:01:44 AMAPASS
Hello i will stop by with the panel scheduals and general says he is finished Thanks Phone #: ###-#### Internet Inspection Request from: Don Lustig corrections made, ok to final, no esc this project, signed occupancy card
ELE08-02001 Rough-In Permanent Service7/21/20087/21/20087/21/2008 8:01:43 AMPPASS
called contractor, ric ok, p/s u/g n ok