Inspections for the day of: Tuesday, July 21, 2015.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-02242 Permanent Service7/20/20157/21/20157/21/2015 2:32:41 PMPFAIL
Inspection for 100amp 3phase 480 Volt Meterbase and Disconnect. These are Mounted on a Pole next to Idaho Power Transformer, inside RSCI construction Lot. Tim ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence called and told electrician that he has to post available fault current and strap riser per NEC
ELE14-01066 Electrical Rough-In7/21/20157/21/20157/21/2015 2:30:15 PMPPASS
Units H216-H220 ceilings, and corridor H256 soffits Phone #: ###-#### Inspection requested via web by Fabian Luna ok cover as requested
ELE15-02239 Rough-In Permanent Service7/20/20157/21/20157/21/2015 2:00:06 PMPCANC
inspection on wiring of 1 room. for questions call jeff Phone #: ###-#### Inspection requested via web by Andrea Creek see ri
ELE15-02239 Electrical Rough-In7/21/20157/21/20157/21/2015 1:56:56 PMPPASS
inspection on wiring of 1 room. for questions call jeff Phone #: ###-#### Inspection requested via web by Andrea Creek room ri ok
ELE15-02151 Final7/20/20157/21/20157/21/2015 1:39:18 PMPPASS
The homeowner is able to be home from 4 pm to 5 pm, for inspection.
call ahead to verify that window at 272.3277 or 340.7376

10 solar panels.
AC micro-inverter system. No DC voltage.
Enphase M250 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed.
Ironridge Integrated Grounding System mid clamps, bonding straps and bonding lugs.
And 275 watt Suniva panels, ETL listed.

A single home run, in metal conduit, is ran from the solar array to the knife switch, located next to meter base. From the knife switch to breaker in main panel, at the bottom of the busing, opposite the feeder lugs. The solar breaker and the knife switch are permanently marked for solar, and the circuit numbers identified in the knife switch and on the panel schedule.

The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service grounding electrode lug at the top of the main panel.
Phone #: ###-#### Inspection requested via web by Ryan King ok final
ELE15-01096 Electrical Rough-In7/21/20157/21/20157/21/2015 12:59:24 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton corrections made, ri ok
ELE15-01811 Electrical Rough-In7/21/20157/21/20157/21/2015 12:20:40 PMPFAIL
Lacey Phone #: ###-#### called owner, left correction notice, NEC 334.30 nm cable shall be secured within 12" of box, 300.4 edge of bored hole shall be 1 1/4" from edge of framing member, 110.3(B) shall install equipment per manufacturer instructions ( ground ferrules ), BCC all make-up shall be done, shall not install panel in clothes closet, see NEC240.24D
ELE15-02093 Electrical Rough-In7/21/20157/21/20157/21/2015 11:39:59 AMPPASS
Andy Phone #: ###-#### corrections made, ri ok
ELE15-02216 Electrical Rough-In7/21/20157/21/20157/21/2015 10:50:33 AMAPASS
Lock box code is 7828 Phone #: ###-#### Inspection requested via web by Shaun Kirkman ri ok lighting and bath
ELE15-01646 Electrical Rough-In7/20/20157/21/20157/21/2015 9:43:25 AMAPASS
Wall rough. Scott is the on site contact. Phone #: ###-#### Inspection requested via web by Buster Bowen wall ri ok per conversation with electrician
ELE15-02248 Final7/21/20157/21/20157/21/2015 9:12:16 AMPCANC
Please call Tate if you have any questions. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan Inspection cancelled from web by: Clay Morgan
ELE15-02248 Electrical Rough-In7/21/20157/21/20157/21/2015 9:12:13 AMPCANC
Please call Tate if you have any questions, thank you. Phone #: ###-#### >> Inspection requested via web by Clay Morgan Inspection cancelled from web by: Clay Morgan
ELE15-02196 Temporary Service7/20/20157/21/20157/21/2015 9:07:40 AMAPASS
call dene with any questions thank you Phone #: ###-#### Inspection requested via web by kim grundhauser t/s u/g n ok
ELE15-01096 Electrical Rough-In7/20/20157/21/20157/21/2015 8:26:49 AMAFAIL
First thing if possible please. Phone #: ###-#### Inspection requested via web by Kerri Hamilton called, left correction notice, NEC 300.4(A) edge of bored hole shall be 1 1/4" from edge of framing member, 330.30(B) shall secure mc cable within 12" of box
ELE15-02171 Electrical Rough-In7/20/20157/21/20157/21/2015 8:00:10 AMAPASS
Please Call Me When You Are There I Have A Few Things To Ask You Please And thank You! Dave Phone #: ###-#### Inspection requested via web by jason shifflett ri ok house
ELE14-03133 Final7/17/20157/21/20157/21/2015 12:00:00 AMPCANC
would like call ahead; Brad Phone #: ###-####