ELE13-02256
| ELE-Aging Inspection | 7/21/2016 | 7/21/2016 | 7/22/2016 4:07:18 PM | | CANC |
|
|
|
ELE15-03901
| Electrical Rough-In | 7/21/2016 | 7/21/2016 | 7/21/2016 4:08:43 PM | A | PASS |
|
|
Call Chris for walk through of 7th floor for pre walk final. Phone #: ###-#### Inspection requested via web by Rafael Castillo In server room repair wall around boxes. Checked all receptacles in all rooms. Core and shall areas not ready.
|
ELE16-01906
| Electrical Rough-In | 7/21/2016 | 7/21/2016 | 7/21/2016 3:52:40 PM | P | PASS |
|
|
Ceiling Inspection level 7 at Wells Fargo Contact Jon Novak ###-#### Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Grid complete rough in ok cover
|
ELE16-01906
| Final | 7/21/2016 | 7/21/2016 | 7/21/2016 3:51:28 PM | P | PASS |
|
|
Ceiling Inspection level 7 at Wells Fargo Contact Jon Novak ###-#### Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Final ok
|
ELE16-01838
| Electrical Rough-In | 7/21/2016 | 7/21/2016 | 7/21/2016 2:25:50 PM | P | PASS |
|
|
Level 7 stack 3 and 4 ceilings. Phone #: ###-#### Inspection requested via web by Brandon Robinson Stack 3 south not ready due to low volt on ceiling support system per 300.11. 3 north and 4 hardlid rough in ok cover
|
ELE15-01348
| Electrical Rough-In | 7/21/2016 | 7/21/2016 | 7/21/2016 2:23:27 PM | P | PASS |
|
|
Level 9 bathrooms ceilings. Call Frank Phone #: ###-#### Inspection requested via web by Brandon Robinson Bathrooms noted hardlid rough in ok cover
|
ELE16-02305
| Permanent Service | 7/19/2016 | 7/21/2016 | 7/21/2016 1:36:14 PM | A | PASS |
|
|
call first, ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER p/s u/g rec ok
|
ELE15-02378
| Final | 7/20/2016 | 7/21/2016 | 7/21/2016 1:10:59 PM | P | FAIL |
|
|
Vince Phone #: ###-#### 210.8- All outdoor 120 volt receptacle outlets shall have GFCI protection. 210.8- All 120 volt receptacle outlets located in garage shall have GFCI protection. 210.11(C)-Bathroom receptacles shall be fed by a dedicated 20 amp circuit that shall have no other outlets.
|
ELE15-02279
| Permanent Service | 7/21/2016 | 7/21/2016 | 7/21/2016 12:03:34 PM | P | PASS |
|
|
EricStory had noted that addressed work clearence and noted location ok due existing service. Contact ###-#### p/s u/g rec ok
|
ELE15-02279
| Final | 7/21/2016 | 7/21/2016 | 7/21/2016 12:03:08 PM | P | PASS |
|
|
EricStory had noted that addressed work clearence and noted location ok due existing service. Contact ###-#### Stair is moveable Final ok
|
ELE16-01868
| Final | 7/20/2016 | 7/21/2016 | 7/21/2016 11:32:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Emmet Bushman Final ok
|
ELE16-02344
| Electrical Rough-In | 7/21/2016 | 7/21/2016 | 7/21/2016 11:09:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt Rough in ok cover
|
ELE16-00758
| Final | 7/20/2016 | 7/21/2016 | 7/21/2016 10:38:23 AM | A | FAIL |
|
|
please call if you have questions thank you Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman 110.3- Basement GFCI will not reset. 210.8- All receptacles serving kitchen counter top areas shall have GFCI protection. 408.4- Circuit directory shall be complete.
|
MIS16-00227
| ELE-Conference | 7/20/2016 | 7/21/2016 | 7/21/2016 9:59:06 AM | A | FAIL |
|
|
Faulty electrical – electrical wires running along the ground inside an irrigation pipe Complaint for back building located on 2706 N. 26th St. Owner of corner lot at 2701 N. 26th gave permission to access his lot to get look at back building. Schedule 40 PVC run on top of ground to corner of back building and runs up into soffit. 230.70- Means shall be provided to disconnect all conductors from a building. 352.10(F)- PVC conduit when ran exposed shall be schedule 80 where subject to physical damage. Install to back building done without pulling permit.
|
ELE16-01634
| Final | 7/20/2016 | 7/21/2016 | 7/21/2016 9:19:20 AM | A | PASS |
|
|
The key is on the meterbase, plz let me know if you have any questions, thx, TW Phone #: ###-#### Inspection requested via web by Stephen Kren Final ok
|
ELE16-00506
| Electrical Rough-In | 7/21/2016 | 7/21/2016 | 7/21/2016 12:00:00 AM | A | PASS |
|
|
We are requesting an underground inspection in the Alley way for this afternoon. Our contact onsite is Bobby ###-####. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate Where 90s leave footing not to depth so will encase in concrete and per 300.5. South 1/2 of alley underground rough in ok cover
|