Inspections for the day of: Thursday, July 21, 2016.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02256 ELE-Aging Inspection7/21/20167/21/20167/22/2016 4:07:18 PM CANC
ELE15-03901 Electrical Rough-In7/21/20167/21/20167/21/2016 4:08:43 PMAPASS
Call Chris for walk through of 7th floor for pre walk final. Phone #: ###-#### Inspection requested via web by Rafael Castillo
In server room repair wall around boxes. Checked all receptacles in all rooms. Core and shall areas not ready.
ELE16-01906 Electrical Rough-In7/21/20167/21/20167/21/2016 3:52:40 PMPPASS
Ceiling Inspection level 7 at Wells Fargo
Contact Jon Novak ###-####
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
Grid complete rough in ok cover
ELE16-01906 Final7/21/20167/21/20167/21/2016 3:51:28 PMPPASS
Ceiling Inspection level 7 at Wells Fargo
Contact Jon Novak ###-####
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek
Final ok
ELE16-01838 Electrical Rough-In7/21/20167/21/20167/21/2016 2:25:50 PMPPASS
Level 7 stack 3 and 4 ceilings. Phone #: ###-#### Inspection requested via web by Brandon Robinson
Stack 3 south not ready due to low volt on ceiling support system per 300.11. 3 north and 4 hardlid rough in ok cover
ELE15-01348 Electrical Rough-In7/21/20167/21/20167/21/2016 2:23:27 PMPPASS
Level 9 bathrooms ceilings. Call Frank Phone #: ###-#### Inspection requested via web by Brandon Robinson
Bathrooms noted hardlid rough in ok cover
ELE16-02305 Permanent Service7/19/20167/21/20167/21/2016 1:36:14 PMAPASS
call first, ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER p/s u/g rec ok
ELE15-02378 Final7/20/20167/21/20167/21/2016 1:10:59 PMPFAIL
Vince Phone #: ###-####
210.8- All outdoor 120 volt receptacle outlets shall have GFCI protection.
210.8- All 120 volt receptacle outlets located in garage shall have GFCI protection.
210.11(C)-Bathroom receptacles shall be fed by a dedicated 20 amp circuit that shall have no other outlets.
ELE15-02279 Permanent Service7/21/20167/21/20167/21/2016 12:03:34 PMPPASS
EricStory had noted that addressed work clearence and noted location ok due existing service. Contact ###-####
p/s u/g rec ok
ELE15-02279 Final7/21/20167/21/20167/21/2016 12:03:08 PMPPASS
EricStory had noted that addressed work clearence and noted location ok due existing service. Contact ###-####
Stair is moveable Final ok
ELE16-01868 Final7/20/20167/21/20167/21/2016 11:32:16 AMAPASS
Phone #: ###-#### Inspection requested via web by Emmet Bushman
Final ok
ELE16-02344 Electrical Rough-In7/21/20167/21/20167/21/2016 11:09:28 AMAPASS
Phone #: ###-#### Inspection requested via web by John VanZandt
Rough in ok cover
ELE16-00758 Final7/20/20167/21/20167/21/2016 10:38:23 AMAFAIL
please call if you have questions thank you Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman
110.3- Basement GFCI will not reset.
210.8- All receptacles serving kitchen counter top areas shall have GFCI protection.
408.4- Circuit directory shall be complete.
MIS16-00227 ELE-Conference7/20/20167/21/20167/21/2016 9:59:06 AMAFAIL
Faulty electrical – electrical wires running along the ground inside an irrigation pipe
Complaint for back building located on 2706 N. 26th St. Owner of corner lot at 2701 N. 26th gave permission to access his lot to get look at back building. Schedule 40 PVC run on top of ground to corner of back building and runs up into soffit.
230.70- Means shall be provided to disconnect all conductors from a building.
352.10(F)- PVC conduit when ran exposed shall be schedule 80 where subject to physical damage.
Install to back building done without pulling permit.

ELE16-01634 Final7/20/20167/21/20167/21/2016 9:19:20 AMAPASS
The key is on the meterbase, plz let me know if you have any questions, thx, TW Phone #: ###-#### Inspection requested via web by Stephen Kren
Final ok
ELE16-00506 Electrical Rough-In7/21/20167/21/20167/21/2016 12:00:00 AMAPASS
We are requesting an underground inspection in the Alley way for this afternoon. Our contact onsite is Bobby ###-####. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate
Where 90s leave footing not to depth so will encase in concrete and per 300.5. South 1/2 of alley underground rough in ok cover