Inspections for the day of: Tuesday, July 22, 2003.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE03-02064 Permanent Service7/21/20037/22/20037/22/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 7/21/2003 at 9:55:09 AM. Contact: ###-####.
p/s o/h rec. ok 7/22/2003 11:25:40 AM
ELE03-02064 Electrical Rough-In7/21/20037/22/20037/22/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 7/21/2003 at 10:47:06 AM. ok 7/22/2003 11:25:20 AM
ELE03-01557 Final7/21/20037/22/20037/22/2003 12:00:00 AMAFAIL
Scheduled by a contractor via Hello! on 7/21/2003 at 12:40:09 PM. Contact: ###-####. cor. posted called 210.52(C)(5) exception outlets on island placed where countertop extends more than 6 inches beyond its base, and north end outlet box overfill 314.16 7/22/2003 11:24:57 AM
ELE03-01176 Final7/21/20037/22/20037/22/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 7/21/2003 at 1:21:03 PM. Contact: ###-####. ok 7/22/2003 9:25:34 AM
ELE03-02119 Temporary Service7/21/20037/22/20037/22/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 7/21/2003 at 3:54:04 PM. Contact: ###-####.
t/s o/h new ok 7/22/2003 10:12:07 AM
ELE03-02121 Temporary Service7/21/20037/22/20037/22/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 7/21/2003 at 3:57:20 PM. Contact: ###-####.
t/s o/h new ok 7/22/2003 10:12:24 AM
ELE03-02194 Temporary Service7/21/20037/22/20037/22/2003 12:00:00 AMAFAIL
###-#### dawn cor. posted called 110.3(B) use manufactures breakers only 7/22/2003 9:26:15 AM
ELE03-00704 Final7/22/20037/22/20037/22/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 7/22/2003 at 6:58:41 AM. Contact: ###-####. ok card signed 7/22/2003 12:50:19 PM
ELE03-00705 Final7/22/20037/22/20037/22/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 7/22/2003 at 7:00:04 AM. Contact: ###-####. ok card signed 7/22/2003 12:50:38 PM
ELE03-01370 Final7/22/20037/22/20037/22/2003 12:00:00 AMPFAIL
PAUL; Phone #: ###-#### Internet Inspection Request from: Dixie Fellows talked with Jim S
owner had soneone else do some wiring job a total mess, they already had a conference, short wires box fill need required outlet spacing, nail plates and 11/4 inches, clamps broken out in 2 gang boxes, using extra thhn with 12/2 for 3 rope 7/22/2003 2:34:03 PM
ELE03-02202 Final7/22/20037/22/20037/22/2003 12:00:00 AMPPASS
PAT..A/C DISCONNECT..; Phone #: ###-#### Internet Inspection Request from: Dixie Fellows ok 7/22/2003 1:57:17 PM
ELE03-02194 Temporary Service7/22/20037/22/20037/22/2003 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 7/22/2003 at 9:44:14 AM. Contact: ###-####.
t/s o/h new ok 7/22/2003 1:37:38 PM