Inspections for the day of: Friday, July 22, 2005.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-02255 Electrical Rough-In7/22/20057/22/20057/22/2005 4:09:35 PMPPASS
ceiling inspection//later around 4pm if possible//loren; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
ELE05-01374 ELE-Aging Inspection7/22/20057/22/20057/22/2005 3:55:46 PM NR
suc
ELE05-02588 Electrical Rough-In7/22/20057/22/20057/22/2005 3:55:25 PMPPASS
verna; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
ELE04-02546 ELE-Aging Inspection7/22/20057/22/20057/22/2005 3:30:03 PM NR
suc
ELE05-02260 Electrical Rough-In7/22/20057/22/20057/22/2005 3:29:36 PMPPART
Scheduled by a contractor via Hello! on 7/22/2005 at 11:05:00 AM. Contact: ###-####.
anop
ELE05-01231 Final7/22/20057/22/20057/22/2005 2:50:26 PMPPASS
gregg ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
ELE05-01091 Final7/22/20057/22/20057/22/2005 2:25:07 PMPPASS
aaron; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
ELE04-03428 Final7/21/20057/22/20057/22/2005 2:24:11 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Heather Packer
210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
(A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (8) shall have ground-fault circuit-interrupter protection for personnel.
(6) Kitchens

210.52(C) Countertops. In kitchens and dining rooms of dwelling units, receptacle outlets for counter spaces shall be installed in accordance with 210.52(C)(1) through (5).

ELE05-02642 Electrical Rough-In7/22/20057/22/20057/22/2005 1:13:17 PMPPART
THIS IS FOR A UNDERGROUND INSPECTION ANY QUESTIONS PLEASE CALL BRIAN KAMINSKI; Phone #: ###-#### Internet Inspection Request
from: Jeff Radford
under pavement oK
ELE03-02903 ELE-Aging Inspection7/22/20057/22/20057/22/2005 12:45:53 PM NR
suc
ELE05-01003 Final7/20/20057/22/20057/22/2005 10:24:30 AMAPASS
Call Dave for access ###-####; Phone #: ###-#### Internet Inspection Request from: Dana Moyer
ELE05-02624 Electrical Rough-In7/21/20057/22/20057/22/2005 10:09:10 AMAPASS
dan ###-####
addition only is on this permit
posted correction for no permit on main house
ELE04-03891 Permanent Service7/20/20057/22/20057/22/2005 9:04:16 AMAFAIL
###-####. Scheduled by a contractor via Hello! on 7/20/2005 at 12:27:38 PM. Contact: ###-####.
314.17 Conductors Entering Boxes, Conduit Bodies, or Fittings.
Conductors entering boxes, conduit bodies, or fittings shall be protected from abrasion and shall comply with 314.17(A) through (D).
300.15 Boxes, Conduit Bodies, or Fittings - Where Required.
Fittings and connectors shall be used only with the specific wiring methods for which they are designed and listed.
230.24 Clearances.
Service-drop conductors shall not be readily accessible and shall comply with 230.24(A) through (D) for services not over 600 volts, nominal.
230.26 Point of Attachment.
In no case shall this point of attachment be less than 3.0 m (10 ft) above finished grade.