ELE10-01793
| ELE-Aging Inspection | 7/22/2014 | 7/22/2014 | 7/23/2014 3:56:02 PM | | CANC |
|
|
|
ELE10-00628
| ELE-Aging Inspection | 7/22/2014 | 7/22/2014 | 7/23/2014 3:53:31 PM | | DONE |
|
|
called to have contractor set up final
|
ELE12-02035
| ELE-Aging Inspection | 7/22/2014 | 7/22/2014 | 7/23/2014 3:42:07 PM | | DONE |
|
|
called to have contractor set up final
|
ELE14-01217
| Final | 7/22/2014 | 7/22/2014 | 7/22/2014 2:57:01 PM | P | PASS |
|
|
Garage entrance code 1979E Phone #: ###-#### >> Inspection requested via web by Alan Lusk ok final
|
ELE14-01279
| Final | 7/22/2014 | 7/22/2014 | 7/22/2014 2:21:37 PM | P | PASS |
|
|
Garage entrance code 1979E. Phone #: ###-#### >> Inspection requested via web by Alan Lusk ok final
|
ELE14-01058
| Final | 7/22/2014 | 7/22/2014 | 7/22/2014 1:48:38 PM | A | PASS |
|
|
Call prior to going Phone #: 2084299799 >> Inspection requested via mobile web by Daniel Weilage ok final
|
ELE14-01976
| Electrical Rough-In | 7/21/2014 | 7/22/2014 | 7/22/2014 1:22:48 PM | A | FAIL |
|
|
>> Inspection requested via web by Rowdy Monroe called, left correction notice, NEC 314.20 boxes shall be flush with finished surface, 110.12(B) shall not use broken boxes, 210.70(A)(3) shall provide lighting outlet under stairs, 334.30 shall not staple nm cable on edge, 334.23 shall protect nm cable within 6' of attic access, 300.4(D) edge of nm cable shall be 1 1/4" from edge of framing member
|
ELE09-01904
| Final | 7/21/2014 | 7/22/2014 | 7/22/2014 12:25:52 PM | A | FAIL |
|
|
Old permit - we''d installed a sub-panel in detached shed. Access is through side gate. Phone #: ###-#### >> Inspection requested via web by steve ragan met owner, told to fix panel schedule and provide gfci protection, call for inspection thru contractor
|
ELE14-01928
| Electrical Rough-In | 7/22/2014 | 7/22/2014 | 7/22/2014 11:54:48 AM | P | PASS |
|
|
OK to cover underground conducts. Phone #: ###-#### >> Inspection requested via web by Roy Kay ok cover u/g
|