MEC20-03032
| Final | 7/22/2020 | 7/22/2020 | 7/22/2020 3:26:06 PM | P | PASS |
|
|
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
|
MEC20-03017
| Final | 7/21/2020 | 7/22/2020 | 7/22/2020 2:37:19 PM | P | PASS |
|
|
INSTALLER DAKOTA ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
|
MEC20-02403
| Final | 7/22/2020 | 7/22/2020 | 7/22/2020 1:50:16 PM | P | PASS |
|
|
Please call ahead to Hugh when headed out to the residence Phone #: ###-#### Inspection requested via web by Sarah Small- furnace a/c coil co locking caps ok- correction on a/c made
|
MEC20-02606
| Final | 7/22/2020 | 7/22/2020 | 7/22/2020 1:41:45 PM | P | CANC |
|
|
INSTALLER JOHN ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
|
MEC20-02606
| Pressure Test | 7/22/2020 | 7/22/2020 | 7/22/2020 1:41:43 PM | P | CANC |
|
|
INSTALLER JOHN ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
|
MEC20-02846
| Rough-in | 7/21/2020 | 7/22/2020 | 7/22/2020 1:27:40 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Chris Gonzalez- need insulation shield and attic panned off around water heater b vent so no insulation cant get down wal and onto pipe
|
MEC20-02846
| Pressure Test | 7/21/2020 | 7/22/2020 | 7/22/2020 1:26:12 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Chris Gonzalez- 20lb gas pass tagged meter location- 5lb flue pass
|
MEC20-02847
| Rough-in | 7/21/2020 | 7/22/2020 | 7/22/2020 1:25:42 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Chris Gonzalez- R/I ok
|
MEC20-02847
| Pressure Test | 7/21/2020 | 7/22/2020 | 7/22/2020 1:25:26 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Chris Gonzalez- 20lb gas pass tagged meter location- 5lb flue pass
|
MEC20-02844
| Rough-in | 7/21/2020 | 7/22/2020 | 7/22/2020 1:24:59 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Chris Gonzalez- R/I ok
|
MEC20-02844
| Pressure Test | 7/21/2020 | 7/22/2020 | 7/22/2020 1:24:43 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Chris Gonzalez- 20lb gas pass tagged meter location- 5lb flue pass
|
MEC20-01487
| DOC - Permit Finaled | 7/22/2020 | 7/22/2020 | 7/22/2020 11:35:08 AM | A | PASS |
|
|
furnace a/c coil co locking caps ok- 5lb flue test- furnace coil and flue test via video
|
MEC20-02790
| Rough-in | 7/21/2020 | 7/22/2020 | 7/22/2020 10:56:37 AM | A | PASS |
|
|
hard lid inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- hard lids ok to cover- need to address 12" OSA thats shown on approved drawingsthat hasnt been ran yet- talked to installer about this to touch basis with engineer will need info by final inspection
|
MEC20-02895
| Rough-in | 7/21/2020 | 7/22/2020 | 7/22/2020 10:30:13 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Konrad Swartz- R/I ok
|
MEC20-02896
| Rough-in | 7/21/2020 | 7/22/2020 | 7/22/2020 10:28:59 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Konrad Swartz- R/I ok
|
MEC20-02606
| Rough-in | 7/21/2020 | 7/22/2020 | 7/22/2020 9:56:39 AM | A | FAIL |
|
|
CONTRACTOR- JUSTIN ###-#### HOME OWNER EILAINE-###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- need to test gas line for reroute and install dante valve for fireplace
|
MEC20-02513
| Rough-in | 7/21/2020 | 7/22/2020 | 7/22/2020 9:56:04 AM | A | PART |
|
|
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/I will pass when dante valve is installed on gas line to fireplace shut off valve is not accessible
|
MEC20-02993
| Rough-in | 7/20/2020 | 7/22/2020 | 7/22/2020 9:24:57 AM | A | FAIL |
|
|
CHRISTINA ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- visqueen touching flue and back of fireplace- needs secured in approved manner
|
MEC20-01487
| Final | 7/17/2020 | 7/22/2020 | 7/22/2020 9:07:07 AM | A | FAIL |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 9 AM. Contact is Don Rapp ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking cas ok- flue not holding pressure- installer will try and fix and send video
|
MEC20-02838
| Rough-in | 7/21/2020 | 7/22/2020 | 7/22/2020 8:47:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- R./I ok- correction made
|
MEC20-03005
| DOC - Permit Finaled | 7/22/2020 | 7/22/2020 | 7/22/2020 8:46:35 AM | A | PASS |
|
|
20lb gas pass to range- crawl piping ok both lines have 2 shutoff with open tee installed- video sent for inspection in house- 20lb gas was already passed to bbq just needed video taken- co installed
|
MEC20-02994
| Final | 7/20/2020 | 7/22/2020 | 7/22/2020 8:37:17 AM | A | NH |
|
|
Early morning< Please call John 30 minutes ahead ###-####7009 Phone #: ###-#### Inspection requested via web by Baldomero Guzman- called number twice no answer- went by no one home- left notice
|
MEC20-03027
| Pressure Test | 7/22/2020 | 7/22/2020 | 7/22/2020 8:24:31 AM | A | FAIL |
|
|
This is next door to the other house brian. Both are ready Thanks Phone #: ###-#### Inspection requested via web by Ed Ables- gauge wont zero out- few place need excvated to 12" deep on in ground piping- recall in when ready
|
MEC20-03026
| Pressure Test | 7/22/2020 | 7/22/2020 | 7/22/2020 8:23:30 AM | A | PASS |
|
|
Gauge is outside in front of house Home owner brian ####-#### As early as possible landscapers are trying to pour concrete as soon as possibl Phone #: ###-#### Inspection requested via web by Ed Ables- 20lb as pass underground ok to backfill- need to see pics of crawl gas piping and boxing around column where gas stub is coming up pipe may need sleeved- talked to Eddy about this
|
MEC20-02317
| DOC - Permit Finaled | 7/22/2020 | 7/22/2020 | 7/22/2020 7:53:13 AM | A | PASS |
|
|
final ok- co installed via pic
|
MEC19-05658
| Mec-Aging Inspection | 7/22/2020 | 7/22/2020 | 7/22/2020 7:43:52 AM | | FAIL |
|
|
contractor needs to schedule inspection- permit not active since issued- permit will expire next aging if no activity
|
MEC19-05632
| Mec-Aging Inspection | 7/22/2020 | 7/22/2020 | 7/22/2020 7:42:46 AM | | FAIL |
|
|
contractor needs to schedule inspection- permit has not been active since issued- permit will expire next aging if no activity
|
MEC19-05649
| Mec-Aging Inspection | 7/22/2020 | 7/22/2020 | 7/22/2020 7:41:46 AM | | FAIL |
|
|
contractor needs to install locking caps per last inspection and send pics for reinspect- permit will expire next aging if no activity
|