Inspections for the day of: Wednesday, July 23, 2014.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRex Boyles
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-02323 ELE-Aging Inspection7/23/20147/23/20147/25/2014 2:12:18 PM DONE
left message for Joshua
ELE14-01623 Final7/22/20147/23/20147/23/2014 3:52:47 PMPFAIL
please contact jason tomlinson after checking in at front desk ###-####, thank you mike rse ###-#### Phone #: ###-#### Inspection requested via web by michael hunt 605.7 multiwire branch circuits supplying power to permanently connected freestanding partitions shall be provided with a means to disconnect simultaneously all ungrounded conductors at the panel. Identify circuits in panel and somewhere on partitions.
ELE12-02024 Final7/23/20147/23/20147/23/2014 3:17:23 PMPPASS
Phone #: ###-#### Inspection requested via web by Sean DeLacy final ok NOTE: Tony Keen with Lea Electric says they will take responsibilty for remaining work associated with underground and fire pump work.
ELE14-02001 Electrical Rough-In7/23/20147/23/20147/23/2014 1:14:44 PMPPASS
Need wall rough-in inspection - Electrician on site Joel Hudson Phone #: ###-#### Inspection requested via web by Kevin Perez r/i ok to cover walls
ELE14-01995 Temporary Service7/23/20147/23/20147/23/2014 12:43:46 PMPPASS
please call to meet on job Phone #: ###-#### Inspection requested via web by Charles Davis t/s o/h n ok
ELE14-01427 Permanent Service7/23/20147/23/20147/23/2014 12:00:18 PMPPASS
Kevin Phone #: ###-#### p/s u/g n ok
ELE14-01160 Final7/22/20147/23/20147/23/2014 11:38:21 AMPPASS
Replace sign cabinet on fascia with new letters reading Burger and Brew. All primary power remained the same. Phone #: ###-#### Inspection requested via web by Ken Olsen
ELE14-01990 Final7/22/20147/23/20147/23/2014 10:32:58 AMAFAIL
Please let me know if there are any problems. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan units rated 15 amp max. fuse or circ. breaker
ELE14-01990 Electrical Rough-In7/22/20147/23/20147/23/2014 10:31:33 AMAPASS
Please let me know if there are any problems. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan r/i ok
ELE14-01506 Final7/22/20147/23/20147/23/2014 9:55:16 AMANR
Keith-Please call at least 30 mins prior to insepction Phone #: ###-#### finish installation of devices, fixtures and blank plates
ELE14-01989 Permanent Service7/22/20147/23/20147/23/2014 9:05:16 AMAPASS
Rocky Phone #: ###-#### p/s o/h n ok
ELE14-01813 Final7/23/20147/23/20147/23/2014 8:12:39 AMAPASS
Phone #: ###-#### Inspection requested via web by Stan Woodward final ok
ELE14-01623 Final7/22/20147/23/20147/22/2014 3:21:13 PMACANC
Mike Phone #: ###-#### Inspection cancelled from web by: michael hunt