Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM07-02513 Water and/or Sewer7/24/20077/24/20077/24/2007 4:19:34 PMPPASS
john; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
PLM07-02513 DOC - Permit Finaled7/24/20077/24/20077/24/2007 4:19:26 PMPPASS
john; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
PLM07-02514 Water and/or Sewer7/24/20077/24/20077/24/2007 4:00:27 PMPPASS
john; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
PLM07-02513 Water and/or Sewer7/24/20077/24/20077/24/2007 4:00:18 PMPPASS
john; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
PLM07-02496 Plumbing Rough-in7/24/20077/24/20077/24/2007 3:26:43 PMPFAIL
dwv test failed, fix backgrade on 3" horizontal drain in 2nd flr overhead, fix backgrade on revent on 2nd flr by tub, support dwv every 4'(vents in overhead)
PLM07-02510 Water and/or Sewer7/24/20077/24/20077/24/2007 2:50:01 PMPPASS
Darwin; Phone #: ###-#### Internet Inspection Request from: Darla Downs
PLM07-02510 DOC - Permit Finaled7/24/20077/24/20077/24/2007 2:49:53 PMPPASS
Darwin; Phone #: ###-#### Internet Inspection Request from: Darla Downs
PLM07-02463 Sprinkler (Final)7/23/20077/24/20077/24/2007 2:04:25 PMAPASS
toni Phone #: ###-####
PLM07-01629 Roof Drains7/24/20077/24/20077/24/2007 2:04:08 PMPPART
Phone #: ###-#### Internet Inspection Request from: JASON MEANS-primary roof drain fan deck, level 3,grid k, 9 thru 6 pass
PLM07-02490 Water and/or Sewer7/23/20077/24/20077/24/2007 12:37:59 PMAPASS
Please call Jay with questions @ ###-####. Thanks! Phone #: ###-#### Internet Inspection Request from: Roger Patterson
PLM07-02490 DOC - Permit Finaled7/24/20077/24/20077/24/2007 12:37:51 PMPPASS
Please call Jay with questions @ ###-####. Thanks! Phone #: ###-#### Internet Inspection Request from: Roger Patterson
PLM07-02062 Groundwork7/24/20077/24/20077/24/2007 12:16:30 PMPCANC
This is for area F. PLease call Bruce with questions ###-#### Phone #: ###-#### Internet Inspection Request from: Sonja Hankel
PLM07-02062 Water and/or Sewer7/24/20077/24/20077/24/2007 12:16:17 PMPCANC
PLease call Bruce with questions ###-#### Phone #: ###-#### Internet Inspection Request from: Sonja Hankel
PLM07-02062 Groundwork7/24/20077/24/20077/24/2007 12:16:00 PMAPART
gw, ws.-area f & water service pass.marked on plans in debest job trailer.
PLM05-04309 Plumbing Rough-in7/23/20077/24/20077/24/2007 11:13:27 AMAPART
9th flr water in walls in rooms 97218,97114,13,12,16,10.
PLM07-02412 Plumbing Rough-in7/23/20077/24/20077/24/2007 9:55:07 AMAPASS
Ready by 10:00AM Phone #: ###-#### Internet Inspection Request from: John Hensley-this was a t&s valve replacement.
PLM07-02412 DOC - Permit Finaled7/24/20077/24/20077/24/2007 9:54:59 AMPPASS
Ready by 10:00AM Phone #: ###-#### Internet Inspection Request from: John Hensley
PLM07-02362 Plumbing Rough-in7/23/20077/24/20077/24/2007 9:46:56 AMAPASS
Ready by 10:00AM Phone #: ###-#### Internet Inspection Request from: John Hensley-this was a t&s & valve replacement.
PLM07-02362 DOC - Permit Finaled7/24/20077/24/20077/24/2007 9:46:03 AMPPASS
Ready by 10:00AM Phone #: ###-#### Internet Inspection Request from: John Hensley
PLM07-01602 Final7/23/20077/24/20077/24/2007 9:31:50 AMAPASS
scott - pls call for access; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
PLM06-03057 Other7/23/20077/24/20077/24/2007 9:15:41 AMADONE
Please see Jason (foreman) for consulation re: main kitchen in B-wing. Thank you. Phone #: ###-#### Internet Inspection Request from: Carl Homola-this was a conferance on backflow devices required in kitchen area.