Inspections for the day of: Wednesday, July 24, 2013.
Number of inspections: 30
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorKimberly M. Johnson
TitleEROSION CONTROL
Phone #208-794-3958
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC13-00199 General Inspection7/24/20137/24/20137/26/2013 3:19:45 PM CANC
ESC13-00184 General Inspection7/24/20137/24/20137/25/2013 2:13:26 PM PASS
Walked job site with foreman and RP. BMPs in place and in god condition. Protecting both private and public storm drain systems. Clean job site. kiddie pools staged on site for next small concrete pour. Conducting self inspections. Moved staging area from south parking lot to north side of project.
ESC13-00194 General Inspection7/24/20137/24/20137/25/2013 11:10:37 AM PASS
permit finaled
ESC13-00605 Site Preparation7/24/20137/24/20137/25/2013 8:36:33 AMPPART
Larry###-####. Performed inspection 7/24 PM and work had started before permit was issued. Had signage up. Discussed with RP to protect inlets. Performed Re-inspection 7/25 AM and trenching contractor brought in straw wattle around down gradient side of trench stockpile however it only laying on the ground and is not staked or trenched in. Straw wattle isn't neccessary for this project. Installed one DI BMP down gradient of work but needs the second DI protected that is located to the east prior to trenching for Jbox electrical connection
ESC12-01007 Aging Inspection7/24/20137/24/20137/24/2013 2:46:33 PM PASS
Finaled
ESC12-01007 DOC - Permit Finaled7/24/20137/24/20137/24/2013 2:46:22 PMPPASS
ESC13-00375 Random Inspection7/24/20137/24/20137/24/2013 2:23:35 PMPFAIL
Written Correction Notice Issued: 1. Pick up trash 2. Washouts must be in contained pit 3. Post ESC sign
ESC12-00815 Aging Inspection7/24/20137/24/20137/24/2013 2:16:54 PM PASS
finaled
ESC12-00815 DOC - Permit Finaled7/24/20137/24/20137/24/2013 2:16:34 PMPPASS
ESC13-00117 General Inspection7/24/20137/24/20137/24/2013 1:54:02 PM CANC
No Activity
ESC12-00930 Aging Inspection7/24/20137/24/20137/24/2013 1:25:39 PM PASS
permit finaled
ESC12-00930 DOC - Permit Finaled7/24/20137/24/20137/24/2013 1:25:15 PMPPASS
ESC12-00845 General Inspection7/24/20137/24/20137/24/2013 1:07:18 PM PART
Washout is full. Stockpile not fully covered with tarp
ESC13-00691 Site Preparation7/24/20137/24/20137/24/2013 12:59:31 PMPPASS
ESC sign up. No other BMPs required at this time. Discussed having concrete washout for trucks and controlling concrete spills from pump truck with RP
ESC13-00196 General Inspection7/24/20137/24/20137/24/2013 10:42:40 AM PASS
permit finaled
ESC13-00196 DOC - Permit Finaled7/24/20137/24/20137/24/2013 10:42:19 AMPPASS
ESC13-00193 General Inspection7/24/20137/24/20137/24/2013 10:34:48 AM PART
Jayo confirmed area has been tackified. Written correction notice posted: 1. Extend Silt fence to south as shown on plan. 2. Install existing silt fence as per specification (trenched in to proper depth and stakes driven in to proper depth).
ESC13-00212 General Inspection7/24/20137/24/20137/24/2013 10:06:45 AM PART
LM for RP: Keep an eye on perimeter control in back; straw wattle was not trenched in but there is wide vegetative buffer down gradient and sod is still in place on upgradient side. Washout is scattered around property and not contained; Must contain washout in centralized pit.
ESC13-00309 General Inspection7/24/20137/24/20137/24/2013 9:38:08 AMPPART
Verbal to RP: Stabilize stockpile in back; write in correct. DI along Woody has filter fabric; will need approved DI protection before rainy season. Filter fabric in DI must be replaced with approved DI BMP if construction is still active in rainy season; okay for now. Job site is clean.
ESC13-00308 General Inspection7/24/20137/24/20137/24/2013 9:37:30 AMPPART
Verbal to RP: Stabilize stockpile in back; write in correct. DI along Woody has filter fabric; will need approved DI protection before rainy season. Filter fabric in DI must be replaced with approved DI BMP if construction is still active in rainy season; okay for now. Job site is clean.
ESC13-00307 General Inspection7/24/20137/24/20137/24/2013 9:36:51 AMPPART
Verbal to RP: Stabilize stockpile in back; write in correct. DI along Woody has filter fabric; will need approved DI protection before rainy season. Filter fabric in DI must be replaced with approved DI BMP if construction is still active in rainy season; okay for now. Job site is clean.
ESC13-00306 General Inspection7/24/20137/24/20137/24/2013 9:35:55 AMPPART
Verbal to RP: Stabilize stockpile in back; write in correct. DI along Woody has filter fabric; will need approved DI protection before rainy season. Filter fabric in DI must be replaced with approved DI BMP if construction is still active in rainy season; okay for now. Job site is clean.
ESC13-00305 General Inspection7/24/20137/24/20137/24/2013 9:33:16 AM PART
Verbal to RP: Stabilize stockpile in back; write in correct Permit number on sign (ESC13-00780 should be ESC13-00305). DI along Woody has filter fabric; will need approved DI protection before rainy season. Filter fabric in DI must be replaced with approved DI BMP if construction is still active in rainy season; okay for now. Job site is clean.
ESC12-01186 Aging Inspection7/24/20137/24/20137/24/2013 8:48:54 AM PASS
ESC12-01186 DOC - Permit Finaled7/24/20137/24/20137/24/2013 8:48:18 AMPPASS
ESC12-01184 Aging Inspection7/24/20137/24/20137/24/2013 8:47:39 AM PASS
permit finaled
ESC12-01184 DOC - Permit Finaled7/24/20137/24/20137/24/2013 8:46:47 AMPPASS
ESC12-01218 DOC - Permit Finaled7/24/20137/24/20137/24/2013 7:58:49 AMPPASS
ESC12-01218 DOC - Permit Finaled7/24/20137/24/20137/24/2013 7:58:48 AMPPASS