ELE11-02728
| ELE-Aging Inspection | 7/24/2015 | 7/24/2015 | 7/24/2015 1:29:45 PM | | DONE |
|
|
Called contractor for permission to final permit due to new law passed in Idaho stating UL listing no longer required for industrial equipment.
|
ELE11-02728
| Final | 7/24/2015 | 7/24/2015 | 7/24/2015 1:29:20 PM | P | PASS |
|
|
UL listed equipment no longer required. Final ok
|
ELE15-02303
| Final | 7/24/2015 | 7/24/2015 | 7/24/2015 1:25:40 PM | P | CANC |
|
|
PLEASE CALL JON FOR ACCESS ###-#### Phone #: ###-#### Inspection requested via web by mike brown Needed Rough in inspection
|
ELE15-02303
| Electrical Rough-In | 7/24/2015 | 7/24/2015 | 7/24/2015 1:01:45 PM | P | PART |
|
|
PLEASE CALL JON FOR ACCESS ###-#### Phone #: ###-#### Inspection requested via web by mike brown Discussed with general contractor enclosed patio would be considered a habitable room, BBQ area flat to window would be acceptable to have receptacle outlet at end of cabinet. Wall space only applys to walls and fixed panels on sliding windows. Basement rec room only rough in ok cover
|
ELE15-02274
| Final | 7/24/2015 | 7/24/2015 | 7/24/2015 12:57:08 PM | P | CANC |
|
|
Rough in only Phone #: ###-#### Inspection requested via web by daniel bibikov Needed a rough in inspection
|
ELE15-02274
| Electrical Rough-In | 7/24/2015 | 7/24/2015 | 7/24/2015 12:21:27 PM | P | PASS |
|
|
Rough in only Phone #: ###-#### Inspection requested via web by daniel bibikov Corrections remain on service underground. Rough in ok cover
|
ELE15-02283
| Electrical Rough-In | 7/24/2015 | 7/24/2015 | 7/24/2015 12:13:37 PM | P | PASS |
|
|
soffit Phone #: ###-#### Inspection requested via web by Kevin Burke Sofffits only rough in ok cover
|
ELE15-01381
| Electrical Rough-In | 7/23/2015 | 7/24/2015 | 7/24/2015 11:51:00 AM | A | PASS |
|
|
Jeremy Phone #: ###-#### Free conductor length ok. Asked owner to protect horizontal runs of NM cable to protect from physical damage. Nail plate shallow holes. Garage to remain unfinished. Rough in ok cover
|
ELE15-01162
| Final | 7/23/2015 | 7/24/2015 | 7/24/2015 11:25:07 AM | A | PASS |
|
|
Requested final. The main part of this job has already been finaled just need this one passed as well. Phone #: ###-#### Inspection requested via web by Shane Lott Final ok
|
ELE15-02299
| Electrical Rough-In | 7/23/2015 | 7/24/2015 | 7/24/2015 11:02:20 AM | A | PASS |
|
|
Please call for access code. Phone #: ###-#### Inspection requested via web by Rick Beckman Bath wall and hard lid rough in ok cover
|
ELE15-01138
| Electrical Rough-In | 7/23/2015 | 7/24/2015 | 7/24/2015 10:39:18 AM | A | PASS |
|
|
We are requesting a final inspection for Phase III only for tomorrow 7/24/15 in the AM. Our onsite contact is Bud @ ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Clint Tate Still have work to do phase 4. Phase 3 pharmacy final ok
|
ELE15-02294
| Permanent Service | 7/23/2015 | 7/24/2015 | 7/24/2015 10:15:15 AM | A | PASS |
|
|
Power off over a year. code #1830 Phone #: ###-#### Inspection requested via web by Eric Schroeder Shall label disconnecting means. p/s u/g rec ok
|
ELE15-02206
| Rough-In Permanent Service | 7/23/2015 | 7/24/2015 | 7/24/2015 9:35:11 AM | A | PASS |
|
|
Please contact Gary ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson Rough in ok cover p/s u/g n ok
|
ELE15-02150
| Final | 7/23/2015 | 7/24/2015 | 7/24/2015 9:08:02 AM | A | PASS |
|
|
4 solar panels. AC micro-inverter system. No DC voltage. Enphase M215 Micro-Inverters, that are CSA, IEEE-1547, and UL-1741 listed. Ironridge Integrated Grounding System mid clamps, bonding straps and bonding lugs. And 250 watt Suniva panels, ETL listed.
A single home run, in metal conduit, is ran from the solar array to the knife switch, located next to meter base. From the knife switch to breaker in sub panel, next to the main inside the garage, at the bottom of the busing, opposite the feeder lugs. The solar breaker and the knife switch are permanently marked for solar, and the circuit numbers identified in the knife switch and on the panel schedule. There is one J box for the homerun, located above the deck under the eve, and its also permanently marked for solar.
The inverters, panels and rails are all bonded with a number 4 ground that runs back to the sub panel. You''ll see two different bare grounds coming down from the rafters, one to each panel. Mine is the new #4 ground. Phone #: ###-#### Inspection requested via web by Ryan King Final ok
|
ELE15-01567
| Rough-In Permanent Service | 7/23/2015 | 7/24/2015 | 7/24/2015 8:46:50 AM | A | PASS |
|
|
Need Trench inspection. Phone #: ###-#### Inspection requested via web by Alan Lusk Underground from shop to house rough in ok cover. Shop service p/s o/h n ok
|
ELE15-01917
| Electrical Rough-In | 7/23/2015 | 7/24/2015 | 7/23/2015 2:04:42 PM | A | PASS |
|
|
Call Tom with time to meet Phone #: ###-#### Inspection requested via web by mike brown Offices, baths, and upstairs area wall and ceilings rough in ok cover
|
ELE15-02165
| Electrical Rough-In | 7/23/2015 | 7/24/2015 | 7/23/2015 1:22:13 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Underground to generator pads rough in ok cover
|