ELE12-02081
| ELE-Aging Inspection | 7/24/2015 | 7/24/2015 | 7/31/2015 7:21:21 AM | | DONE |
|
|
too busy
|
ELE13-00565
| ELE-Aging Inspection | 7/24/2015 | 7/24/2015 | 7/31/2015 7:20:48 AM | | DONE |
|
|
too busy
|
ELE13-01412
| ELE-Aging Inspection | 7/24/2015 | 7/24/2015 | 7/31/2015 7:20:19 AM | | DONE |
|
|
too busy
|
ELE10-02067
| ELE-Aging Inspection | 7/24/2015 | 7/24/2015 | 7/28/2015 10:54:38 AM | | DONE |
|
|
Left message for Miles
|
ELE15-02177
| Electrical Rough-In | 7/23/2015 | 7/24/2015 | 7/24/2015 2:52:12 PM | P | PASS |
|
|
As late as possible Phone #: 8411007 >> Inspection requested via mobile web by Matt sub panel install ok firred out walls need 11/4" from face of stud to bored hole..Use nailplates where needed
|
GCE15-00116
| GCE-Final | 7/24/2015 | 7/24/2015 | 7/24/2015 1:48:37 PM | P | PASS |
|
|
David ###-#### FINAL OK on t/s
|
GCE15-00116
| GCE-Temporary Service | 7/24/2015 | 7/24/2015 | 7/24/2015 1:46:51 PM | P | PASS |
|
|
David ###-#### t/s u/g n ok
|
ELE13-01381
| Final | 7/23/2015 | 7/24/2015 | 7/24/2015 12:20:13 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Clint Tate final ok
|
ELE15-02036
| Final | 7/23/2015 | 7/24/2015 | 7/24/2015 12:07:19 PM | A | PASS |
|
|
Someone will be there all day Phone #: ###-#### Inspection requested via web by Neal Rumsey final ok
|
ELE14-03333
| Final | 7/22/2015 | 7/24/2015 | 7/24/2015 11:48:17 AM | A | PART |
|
|
Contact: Jeremy Thornock Phone #: ###-#### Inspection requested via web by Deb Gooden final ok all of parking garage only also discuss temp. occupancy
|
ELE15-02132
| Conference | 7/23/2015 | 7/24/2015 | 7/24/2015 11:14:38 AM | A | DONE |
|
|
Discuss location of receptacles in islands. Phone #: ###-#### Inspection requested via web by Rafael Castillo cut in receptacles under countertop instead of cabinets ok Discuss temp. occupancy status after rooms are finaled is ok per wing
|
ELE14-03334
| Final | 7/24/2015 | 7/24/2015 | 7/24/2015 10:38:47 AM | A | PART |
|
|
electrical rm 2 needs diversion pan above metering section for plumbing waste pipes above
|
ELE14-01948
| Final | 7/24/2015 | 7/24/2015 | 7/24/2015 10:18:53 AM | A | PASS |
|
|
Contact: Jeremy Thornock Phone #: ###-#### Inspection requested via web by Deb Gooden final ok on original groundwork permit
|
ELE14-03335
| Final | 7/24/2015 | 7/24/2015 | 7/24/2015 10:17:02 AM | A | PART |
|
|
Contact: Jeremy Thornock Phone #: ###-#### Inspection requested via web by Deb Gooden need to see finish fixtures in rental office, flash rings in clubhouse wallpaper area receptacles and panel schedule , EDP breakers for heat tape, pool equipment room and spa e- stop, exterior lighting handholes and fixtures.
|
ELE14-03336
| Final | 7/24/2015 | 7/24/2015 | 7/24/2015 10:12:45 AM | A | PART |
|
|
Contact: Jeremy Thornock Phone #: ###-#### Inspection requested via web by Deb Gooden need to see diversion pan over service 2 norhtwest electrical rm. metering. Did walk thru with YMC. Need to see 2nd flr IT closet mini split.
|
GCE15-00070
| GCE-Final | 7/23/2015 | 7/24/2015 | 7/24/2015 8:33:49 AM | A | PASS |
|
|
Calvin ###-#### corrections made final ok
|
ELE15-02177
| Electrical Rough-In | 7/23/2015 | 7/24/2015 | 7/23/2015 11:45:02 PM | A | CANC |
|
|
As late as possible Phone #: 8411007 >> Inspection requested via mobile web by Matt Inspection cancelled via mobile web on Thursday, July 23, 2015.
|
ELE15-02258
| Rough-In Permanent Service | 7/23/2015 | 7/24/2015 | 7/23/2015 2:19:30 PM | A | CANC |
|
|
Any questions please let me know, thx, TW Phone #: ###-#### >> Inspection requested via web by Stephen Kren Inspection cancelled from web by: Stephen Kren
|
ELE15-01138
| Final | 7/23/2015 | 7/24/2015 | 7/23/2015 1:33:57 PM | A | CANC |
|
|
We are requesting a final inspection for tomorrow 7/24/15 in the AM. Our onsite contact is Bud @ ###-####. Thank you! Phone #: ###-#### >> Inspection requested via web by Clint Tate Inspection cancelled from web by: Clint Tate
|