Inspections for the day of: Monday, July 24, 2017.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-03214 Final7/21/20177/24/20177/24/2017 3:57:44 PMPPASS
Inspection requested via web by Margie Rowe
MEC17-00256 Final7/21/20177/24/20177/24/2017 3:33:32 PMPNH
Darcie would prefer 3-4 pm. Please call 1 hour prior to arrival so she can make sure that she is there. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- no one home- called number listed and left message prior to stopping
MEC17-03202 Final7/20/20177/24/20177/24/2017 3:32:12 PMPCANC
LATE PM PLEASE. PLEASE CALL OUR INSTALLER JESSE AT ###-#### Phone #: ###-#### >> Inspection requested via web by Ben Welgan Inspection cancelled from web by: Ben Welgan
MEC17-03221 Final7/21/20177/24/20177/24/2017 3:09:17 PMPFAIL
Call customer when on your way Phone #: ###-#### Inspection requested via web by Kristin Dolan- need wet switch on secondary drain- need right size breaker in panel- need a screw in cover in breaker panel - need to schedule inspection with Jeff owner ###-####
MEC17-02851 Final7/24/20177/24/20177/24/2017 2:44:24 PMACANC
9- 930 am ###-####- schedule for wrong day by me
MEC17-03204 Rough-in7/24/20177/24/20177/24/2017 2:36:41 PMPPASS
robert 208 412 6713- furnace and ac not set yet- contractor working with builder in furnace/linen closet upstairs will be complete by final-
MEC17-03204 Pressure Test7/24/20177/24/20177/24/2017 2:29:49 PMPPASS
2olb gas pass- 5lb flue pass
MEC17-03179 Final7/24/20177/24/20177/24/2017 1:53:46 PMPPASS
1pmish please call Dave ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
MEC17-03179 Pressure Test7/24/20177/24/20177/24/2017 1:52:44 PMPPASS
1pmish please call Dave ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- 20lb gas pass- 5lb flue pass
MEC17-01321 Final7/24/20177/24/20177/24/2017 1:10:06 PMPPASS
Field Super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC17-01498 Final7/21/20177/24/20177/24/2017 11:21:45 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino
MEC16-04377 Final7/21/20177/24/20177/24/2017 10:37:46 AMAPASS
Morning is fine. Thank you! Phone #: ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
MEC16-03400 Final7/21/20177/24/20177/24/2017 10:37:26 AMAPASS
Morning is fine. Thank you! Phone #: ###-#### Inspection requested via web by Andrea Grigsby
MEC16-05459 Final7/21/20177/24/20177/24/2017 10:11:46 AMAPASS
Call Patricia one hour before arrival ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
MEC17-00333 Final7/21/20177/24/20177/24/2017 9:37:28 AMAPASS
Please Call Alma 1 hour before arrival ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
MEC17-03012 Final7/21/20177/24/20177/24/2017 9:36:19 AMAPASS
Contact Alma 1 Hour prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby
MEC17-02370 Final7/21/20177/24/20177/24/2017 9:14:22 AMAFAIL
code 121315 Phone #: ###-#### Inspection requested via web by Brian Preece- need installation insriction onsite for mantel clearances- i checked all drawers for these could not find any
MEC16-04812 Final7/21/20177/24/20177/24/2017 9:00:48 AMAPASS
Please Call Traci 1 hour before arrival ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
MEC17-03204 Rough-in7/21/20177/24/20177/24/2017 8:45:57 AMAFAIL
Richard Phone #: ###-####- gas at zero needs 30lb guage not 15lb- csst cant penetrate appiance fireplace with protective sleeve- need to pressure test flue 2nd floor- need approved nail plate in laundry room for csst gas piping- dryer vent is oval at top plate need to maintain 4" round- exhaust duct in laundry room needs supported- master bedroom need RA or transfer grill installed not shown on manual J- supply main 2nd floor needs finished to furnace room-lineset needs strapped up in attic- bedroom 2nd floor west side needs supply register leveled and supported better at ceiling- supply joints needs sealed 2nd floor on elbows- left correction notice in garage on supply line
MEC17-03204 Pressure Test7/21/20177/24/20177/24/2017 8:40:23 AMAFAIL
Richard Phone #: ###-####- gas guage a 0 and needs to be 30lb guage not 15 lb- flue needs tested 2nd floor