MEC17-03214
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 3:57:44 PM | P | PASS |
|
|
Inspection requested via web by Margie Rowe
|
MEC17-00256
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 3:33:32 PM | P | NH |
|
|
Darcie would prefer 3-4 pm. Please call 1 hour prior to arrival so she can make sure that she is there. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- no one home- called number listed and left message prior to stopping
|
MEC17-03202
| Final | 7/20/2017 | 7/24/2017 | 7/24/2017 3:32:12 PM | P | CANC |
|
|
LATE PM PLEASE. PLEASE CALL OUR INSTALLER JESSE AT ###-#### Phone #: ###-#### >> Inspection requested via web by Ben Welgan Inspection cancelled from web by: Ben Welgan
|
MEC17-03221
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 3:09:17 PM | P | FAIL |
|
|
Call customer when on your way Phone #: ###-#### Inspection requested via web by Kristin Dolan- need wet switch on secondary drain- need right size breaker in panel- need a screw in cover in breaker panel - need to schedule inspection with Jeff owner ###-####
|
MEC17-02851
| Final | 7/24/2017 | 7/24/2017 | 7/24/2017 2:44:24 PM | A | CANC |
|
|
9- 930 am ###-####- schedule for wrong day by me
|
MEC17-03204
| Rough-in | 7/24/2017 | 7/24/2017 | 7/24/2017 2:36:41 PM | P | PASS |
|
|
robert 208 412 6713- furnace and ac not set yet- contractor working with builder in furnace/linen closet upstairs will be complete by final-
|
MEC17-03204
| Pressure Test | 7/24/2017 | 7/24/2017 | 7/24/2017 2:29:49 PM | P | PASS |
|
|
2olb gas pass- 5lb flue pass
|
MEC17-03179
| Final | 7/24/2017 | 7/24/2017 | 7/24/2017 1:53:46 PM | P | PASS |
|
|
1pmish please call Dave ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
|
MEC17-03179
| Pressure Test | 7/24/2017 | 7/24/2017 | 7/24/2017 1:52:44 PM | P | PASS |
|
|
1pmish please call Dave ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- 20lb gas pass- 5lb flue pass
|
MEC17-01321
| Final | 7/24/2017 | 7/24/2017 | 7/24/2017 1:10:06 PM | P | PASS |
|
|
Field Super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC17-01498
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 11:21:45 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino
|
MEC16-04377
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 10:37:46 AM | A | PASS |
|
|
Morning is fine. Thank you! Phone #: ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
MEC16-03400
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 10:37:26 AM | A | PASS |
|
|
Morning is fine. Thank you! Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
MEC16-05459
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 10:11:46 AM | A | PASS |
|
|
Call Patricia one hour before arrival ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
MEC17-00333
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 9:37:28 AM | A | PASS |
|
|
Please Call Alma 1 hour before arrival ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
MEC17-03012
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 9:36:19 AM | A | PASS |
|
|
Contact Alma 1 Hour prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
MEC17-02370
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 9:14:22 AM | A | FAIL |
|
|
code 121315 Phone #: ###-#### Inspection requested via web by Brian Preece- need installation insriction onsite for mantel clearances- i checked all drawers for these could not find any
|
MEC16-04812
| Final | 7/21/2017 | 7/24/2017 | 7/24/2017 9:00:48 AM | A | PASS |
|
|
Please Call Traci 1 hour before arrival ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
MEC17-03204
| Rough-in | 7/21/2017 | 7/24/2017 | 7/24/2017 8:45:57 AM | A | FAIL |
|
|
Richard Phone #: ###-####- gas at zero needs 30lb guage not 15lb- csst cant penetrate appiance fireplace with protective sleeve- need to pressure test flue 2nd floor- need approved nail plate in laundry room for csst gas piping- dryer vent is oval at top plate need to maintain 4" round- exhaust duct in laundry room needs supported- master bedroom need RA or transfer grill installed not shown on manual J- supply main 2nd floor needs finished to furnace room-lineset needs strapped up in attic- bedroom 2nd floor west side needs supply register leveled and supported better at ceiling- supply joints needs sealed 2nd floor on elbows- left correction notice in garage on supply line
|
MEC17-03204
| Pressure Test | 7/21/2017 | 7/24/2017 | 7/24/2017 8:40:23 AM | A | FAIL |
|
|
Richard Phone #: ###-####- gas guage a 0 and needs to be 30lb guage not 15 lb- flue needs tested 2nd floor
|