Inspections for the day of: Friday, July 24, 2020.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE20-02580 Electrical Rough-In7/24/20207/24/20207/24/2020 3:40:02 PMPCANC
screened - exposed to someone with COVID, tested negative // David Phone #: ###-#### Called Brittany ELE20-02204 finaled after permanent service passed. Owner called Gemma and was unable to resolve issue so he pulled a 2nd permit ELE20-02580 so work could continue. 1st permit to be re-openned and 2nd to be voided.
ELE20-02204 Electrical Rough-In7/24/20207/24/20207/24/2020 3:35:48 PMPFAIL
Owners 1st. permit finaled by mistake after permenant service inspection. Called Gemma and was unable to resolve so owner pulled second permit ELE20-02580 so work could continue. Fees for work should be 1 time charge of $165.00. Both permits had same fee but owner charged 2 for his swelling remodel. 300.4- 6 locations require nail plates. 300.15- Exisitng wiring shall terminat in a box or be removed. Old range, old washer. 210.11- Kitchen small appliance circuits shall have no other outlets. Patio outdoor receptacle fed by kitchen circuit.
ELE19-00601 Electrical Rough-In7/24/20207/24/20207/24/2020 1:44:49 PMPPASS
UG cover for 6th street side historic lights. Phone #: ###-#### Inspection requested via web by Buster Bowen Informed all wiring on load side of electrical service for public works lighting or equipment must be inspected by a public works inspector. Contact informed of confusion on which inspector is required so has call both in for inspections. 6th street sidewalk light pole underground rough in ok cover.
ELE20-01677 Final7/23/20207/24/20207/24/2020 12:31:40 PMAPASS
Phone #: ###-#### Inspection requested via web by Kevin Burke Final ok
ELE20-02572 Temporary Service7/23/20207/24/20207/24/2020 11:08:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Troy Ballard t/s u/g n ok
ELE20-02535 Temporary Service7/23/20207/24/20207/24/2020 10:11:43 AMAPASS
Phone #: ###-#### Inspection requested via web by Angela Stears t/s u/g n ok
ELE20-02534 Temporary Service7/23/20207/24/20207/24/2020 10:11:14 AMAPASS
Phone #: ###-#### Inspection requested via web by Angela Stears t/s u/g n ok
ELE20-02565 Final7/23/20207/24/20207/24/2020 9:55:14 AMAPASS
Shed 1-###-#### Phone #: ###-#### Inspection requested via web by Kendra Lanham Final ok