ELE20-02581
| Permanent Service | 7/24/2020 | 7/24/2020 | 7/24/2020 2:59:37 PM | P | PASS |
|
|
Replace load center on 100amp underground fed electrical panel - Phone #: ###-#### Inspection requested via web by Kendra Lanham ID power had a late disc. Panel being replace due to bad utility phase conductor. 2 ground rods driven and all peices needed to complete panel swap onsite. p/s u/g rec ok
|
ELE20-02579
| Final | 7/23/2020 | 7/24/2020 | 7/24/2020 2:57:04 PM | P | PASS |
|
|
Doing a service upgrade. Power is getting turned off at 9am. Requesting time to change out equipment. Please call in am so I can be in contact to let you know when I''m getting close to finishing. Thanks Phone #: ###-#### Inspection requested via web by Mark Galban contractor still working on branch circuits at time of inspection. Grounding complete and mast installed. p/s o/h rec ok
|
ELE20-02579
| Permanent Service | 7/24/2020 | 7/24/2020 | 7/24/2020 2:54:55 PM | P | PASS |
|
|
Doing a service upgrade. Power is getting turned off at 9am. Requesting time to change out equipment. Please call in am so I can be in contact to let you know when I''m getting close to finishing. Thanks Phone #: ###-#### Inspection requested via web by Mark Galban Contractor was re-installing branch circuits at time of inspection. Grounding checked, Mast installed. p/s o/h rec ok
|
ELE20-02372
| Electrical Rough-In | 7/24/2020 | 7/24/2020 | 7/24/2020 12:59:38 PM | P | PASS |
|
|
Dane - */Screened*/ Phone #: ###-#### upstairs and Garage addition only ok to cover
|
ELE20-01524
| Final | 7/24/2020 | 7/24/2020 | 7/24/2020 11:11:53 AM | P | PASS |
|
|
The key is front of the building (between the two single doors) inside bubble cover Phone #: ###-#### Inspection requested via web by Greg Traudt final ok
|
ELE20-00465
| Final | 7/23/2020 | 7/24/2020 | 7/24/2020 11:03:12 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt No access Dining room receps(Covered in plastic) Master bed receps Dead, Range plate missing, Exsposed live wire in up bed A/V cabinet, Install receps in up work area, Re-label panel schedule.
|
ELE20-01516
| Electrical Rough-In | 7/24/2020 | 7/24/2020 | 7/24/2020 10:30:47 AM | A | FAIL |
|
|
Code 3480 Phone #: ###-#### Inspection requested via web by Dave Brueggemann 300.15. All wire shall terminate in a box.( Any abandoned, accessible Rag wire shall be removed or terminated in box) 300.4 Nail plates needed in kitchen back spalsh and under living room window. 210.52 Recep need added L&R of master slider and R of living room slider and Dining room wall. 210.70A2. All exits shall have wall controlled exterior lighting.210.52E3 All decks and patios shall have receps. Range and A/C wire need terminated in panel. Please install panel cover or protective front durring construction. Mech room needs light and recep before final
|
ELE20-01565
| Final | 7/24/2020 | 7/24/2020 | 7/24/2020 9:12:14 AM | A | PASS |
|
|
Call 30 minutes ahead for Jim to meet you Phone #: ###-#### Inspection requested via web by Jim Williams remaining light fixtures installed final ok
|
ELE20-02556
| Final | 7/23/2020 | 7/24/2020 | 7/24/2020 9:03:15 AM | A | PASS |
|
|
Justin is our contact. He has made arrangements for virtual inspection with inspector due to activity at job site. Thank you Phone #: ###-#### Inspection requested via web by Kelly Felin final ok
|
ELE20-02556
| Electrical Rough-In | 7/24/2020 | 7/24/2020 | 7/24/2020 9:03:00 AM | P | PASS |
|
|
Justin is our contact. He has made arrangements for virtual inspection with inspector due to activity at job site. Thank you Phone #: ###-#### Inspection requested via web by Kelly Felin Sub panel and electric heater rough in ok.
|
ELE20-00404
| Final | 7/23/2020 | 7/24/2020 | 7/24/2020 8:43:28 AM | A | PASS |
|
|
Final inspection Building #12. Thank you Phone #: ###-#### Inspection requested via web by Stuart Welton Building 12 only final ok
|
ELE20-00225
| Electrical Rough-In | 7/23/2020 | 7/24/2020 | 7/24/2020 12:00:00 AM | P | PASS |
|
|
Need trench inspected Phone #: ###-#### Inspection requested via web by robert feller Underground for remaining units and electrical room only ok to cover (no ufer preasent in footing)
|
ELE20-02372
| Electrical Rough-In | 7/22/2020 | 7/24/2020 | 7/23/2020 9:24:37 PM | A | CANC |
|
|
Dane *screened* *Virtural, occ home. Phone #: ###-#### Inspection cancelled from web by: Dane Oldham
|