MEC20-02983
| Final | 7/23/2020 | 7/24/2020 | 7/24/2020 3:41:34 PM | P | PASS |
|
|
Please call Taylor ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co locking caps ok
|
MEC20-02346
| Rough-in | 7/24/2020 | 7/24/2020 | 7/24/2020 3:28:01 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Arielle Hendricks 1- need city approved man j onsite 2- seal all spot welds on supply boots 3- need ladder provided to access furnace in attic 4- OSA can ot terminate to roof 5- access to attic needs 24" wide access to platform with 30" clearance to front of furnace and unobstructed has plumbing vent in way 6- insulation on supply main needs taped in multiple locations where insulation is showing 7- primary condensate has trap in it needs 1/4" per foot grade from coil to outside and nail plates at top plate
correction notice posted
DO NOT COVER
|
MEC20-02346
| Pressure Test | 7/24/2020 | 7/24/2020 | 7/24/2020 3:24:22 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Arielle Hendricks- 20lb gas pass tagged meter location
|
MEC20-03034
| Final | 7/22/2020 | 7/24/2020 | 7/24/2020 3:01:25 PM | P | PASS |
|
|
INSTALLER JEREMY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
|
MEC20-03057
| Final | 7/24/2020 | 7/24/2020 | 7/24/2020 2:23:18 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
MEC20-03031
| Final | 7/22/2020 | 7/24/2020 | 7/24/2020 1:49:21 PM | P | PASS |
|
|
INSTALLER GERRY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok- 5lb flue pass witnessed by homeowner to keep job going
|
MEC20-03068
| Final | 7/24/2020 | 7/24/2020 | 7/24/2020 1:17:04 PM | P | NR |
|
|
Please call Brandon to verify inspection time. This may require video inspection. Phone #: ###-#### Inspection requested via web by max sanders- still installing- pvc needs minimum 6" clearance to single wall water heater flue- condensate looks trapped outside
|
MEC20-02974
| Final | 7/22/2020 | 7/24/2020 | 7/24/2020 1:03:03 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
|
MEC20-03046
| Final | 7/23/2020 | 7/24/2020 | 7/24/2020 12:34:07 PM | P | FAIL |
|
|
No one is living in the home currently, it''s under renovation. Please call Brian prior to arrival at ###-####. Phone #: ###-#### Inspection requested via web by Bryan Palmer- air handler coil co ok- need 3 locking caps installed on heat pump service ports- send pic for reinspect
|
MEC20-03070
| Final | 7/24/2020 | 7/24/2020 | 7/24/2020 11:41:35 AM | P | PASS |
|
|
Inspection requested via web by max sanders- final ok
|
MEC20-03070
| Pressure Test | 7/24/2020 | 7/24/2020 | 7/24/2020 11:41:12 AM | P | PASS |
|
|
Please call home owner 30 min in advance. Phone #: ###-#### Inspection requested via web by max sanders- 20lb gas pass
|
MEC20-02017
| Final | 7/23/2020 | 7/24/2020 | 7/24/2020 11:20:07 AM | A | FAIL |
|
|
The tennant will be leaving at 11:30. Can you call her before heading over (###-####). If you think it''s going to be around 11:30, give me a call, and I can head over.
I left the approved copy of man j, by the mechanical room in the garage. The furnace is in the crawl space. Phone #: ###-#### Inspection requested via web by Nat Golden- need air balance report- need insulation completed in crawl numerous places- 20lb gas pass in crawl- need electrical permit issued for electrical work- rest is good
|
MEC20-02346
| Final | 7/24/2020 | 7/24/2020 | 7/24/2020 11:11:56 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
|
MEC20-03060
| Rough-in | 7/23/2020 | 7/24/2020 | 7/24/2020 9:49:42 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Kristy Watson- crawl needs completed still installing
|
MEC20-03060
| Pressure Test | 7/23/2020 | 7/24/2020 | 7/24/2020 9:48:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kristy Watson- 20lb gas pass tagged meter location
|
MEC20-03059
| Final | 7/23/2020 | 7/24/2020 | 7/24/2020 9:20:03 AM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by Loren Bailey- no one home- no access- reschedule when someone available for inspection
|
MEC19-05603
| Final | 7/24/2020 | 7/24/2020 | 7/24/2020 9:11:15 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- all unit 1st 2nd and 3rd floors ok- temp occupancy ok- need condensate rerouted one unit - need one door removed to see inside off air handler- dryers need termination duct installed couple units to verify install- Went over with Justin and GC onsite - will reschedule when ready
|
MEC20-02994
| Final | 7/24/2020 | 7/24/2020 | 7/24/2020 8:19:06 AM | A | FAIL |
|
|
815 am- secondary drain needs ran to garage floor or install wet switch- 1 plug on coil missing- recall in when corrections made
|
MEC20-02513
| Rough-in | 7/24/2020 | 7/24/2020 | 7/24/2020 7:51:44 AM | A | PASS |
|
|
fireplace R/I ok- call in final when ready
|
MEC19-05732
| Mec-Aging Inspection | 7/24/2020 | 7/24/2020 | 7/24/2020 7:41:46 AM | | CANC |
|
|
|
MEC19-05732
| DOC - Permit Finaled | 7/24/2020 | 7/24/2020 | 7/24/2020 7:41:40 AM | A | PASS |
|
|
final ok-
|
MEC19-05728
| Mec-Aging Inspection | 7/24/2020 | 7/24/2020 | 7/24/2020 7:40:30 AM | | FAIL |
|
|
contractor needs to reschedule inspection was not ready last inspection- permit will expire next aging if no activity
|
MEC20-02974
| Final | 7/21/2020 | 7/24/2020 | 7/22/2020 7:32:46 AM | P | CANC |
|
|
INSTALLER DAKOTA ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
|
MEC20-02974
| Final | 7/20/2020 | 7/24/2020 | 7/21/2020 7:44:55 AM | P | CANC |
|
|
INSTALLER DUSTIN ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
|