Inspections for the day of: Friday, July 24, 2020.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-02983 Final7/23/20207/24/20207/24/2020 3:41:34 PMPPASS
Please call Taylor ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co locking caps ok
MEC20-02346 Rough-in7/24/20207/24/20207/24/2020 3:28:01 PMPFAIL
Phone #: ###-#### Inspection requested via web by Arielle Hendricks
1- need city approved man j onsite
2- seal all spot welds on supply boots
3- need ladder provided to access furnace in attic
4- OSA can ot terminate to roof
5- access to attic needs 24" wide access to platform with 30" clearance to front of furnace and unobstructed has plumbing vent in way
6- insulation on supply main needs taped in multiple locations where insulation is showing
7- primary condensate has trap in it needs 1/4" per foot grade from coil to outside and nail plates at top plate

correction notice posted

DO NOT COVER
MEC20-02346 Pressure Test7/24/20207/24/20207/24/2020 3:24:22 PMPPASS
Phone #: ###-#### Inspection requested via web by Arielle Hendricks- 20lb gas pass tagged meter location
MEC20-03034 Final7/22/20207/24/20207/24/2020 3:01:25 PMPPASS
INSTALLER JEREMY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
MEC20-03057 Final7/24/20207/24/20207/24/2020 2:23:18 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC20-03031 Final7/22/20207/24/20207/24/2020 1:49:21 PMPPASS
INSTALLER GERRY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok- 5lb flue pass witnessed by homeowner to keep job going
MEC20-03068 Final7/24/20207/24/20207/24/2020 1:17:04 PMPNR
Please call Brandon to verify inspection time. This may require video inspection. Phone #: ###-#### Inspection requested via web by max sanders- still installing- pvc needs minimum 6" clearance to single wall water heater flue- condensate looks trapped outside
MEC20-02974 Final7/22/20207/24/20207/24/2020 1:03:03 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
MEC20-03046 Final7/23/20207/24/20207/24/2020 12:34:07 PMPFAIL
No one is living in the home currently, it''s under renovation. Please call Brian prior to arrival at ###-####. Phone #: ###-#### Inspection requested via web by Bryan Palmer- air handler coil co ok- need 3 locking caps installed on heat pump service ports- send pic for reinspect
MEC20-03070 Final7/24/20207/24/20207/24/2020 11:41:35 AMPPASS
Inspection requested via web by max sanders- final ok
MEC20-03070 Pressure Test7/24/20207/24/20207/24/2020 11:41:12 AMPPASS
Please call home owner 30 min in advance. Phone #: ###-#### Inspection requested via web by max sanders- 20lb gas pass
MEC20-02017 Final7/23/20207/24/20207/24/2020 11:20:07 AMAFAIL
The tennant will be leaving at 11:30. Can you call her before heading over (###-####). If you think it''s going to be around 11:30, give me a call, and I can head over.

I left the approved copy of man j, by the mechanical room in the garage. The furnace is in the crawl space. Phone #: ###-#### Inspection requested via web by Nat Golden- need air balance report- need insulation completed in crawl numerous places- 20lb gas pass in crawl- need electrical permit issued for electrical work- rest is good
MEC20-02346 Final7/24/20207/24/20207/24/2020 11:11:56 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
MEC20-03060 Rough-in7/23/20207/24/20207/24/2020 9:49:42 AMANR
Phone #: ###-#### Inspection requested via web by Kristy Watson- crawl needs completed still installing
MEC20-03060 Pressure Test7/23/20207/24/20207/24/2020 9:48:21 AMAPASS
Phone #: ###-#### Inspection requested via web by Kristy Watson- 20lb gas pass tagged meter location
MEC20-03059 Final7/23/20207/24/20207/24/2020 9:20:03 AMANH
Phone #: ###-#### Inspection requested via web by Loren Bailey- no one home- no access- reschedule when someone available for inspection
MEC19-05603 Final7/24/20207/24/20207/24/2020 9:11:15 AMAPART
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- all unit 1st 2nd and 3rd floors ok- temp occupancy ok- need condensate rerouted one unit - need one door removed to see inside off air handler- dryers need termination duct installed couple units to verify install- Went over with Justin and GC onsite - will reschedule when ready
MEC20-02994 Final7/24/20207/24/20207/24/2020 8:19:06 AMAFAIL
815 am- secondary drain needs ran to garage floor or install wet switch- 1 plug on coil missing- recall in when corrections made
MEC20-02513 Rough-in7/24/20207/24/20207/24/2020 7:51:44 AMAPASS
fireplace R/I ok- call in final when ready
MEC19-05732 Mec-Aging Inspection7/24/20207/24/20207/24/2020 7:41:46 AM CANC
MEC19-05732 DOC - Permit Finaled7/24/20207/24/20207/24/2020 7:41:40 AMAPASS
final ok-
MEC19-05728 Mec-Aging Inspection7/24/20207/24/20207/24/2020 7:40:30 AM FAIL
contractor needs to reschedule inspection was not ready last inspection- permit will expire next aging if no activity
MEC20-02974 Final7/21/20207/24/20207/22/2020 7:32:46 AMPCANC
INSTALLER DAKOTA ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
MEC20-02974 Final7/20/20207/24/20207/21/2020 7:44:55 AMPCANC
INSTALLER DUSTIN ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt