Inspections for the day of: Friday, July 24, 2020.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-03022 Pressure Test7/24/20207/24/20207/24/2020 3:45:54 PMPPASS
Please call Brad when you are on your way at ###-#### and call Eddie with questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum
- 60lb gas test ok
MEC20-03069 Final7/24/20207/24/20207/24/2020 3:27:43 PMPPASS
Please call Ben to verify inspection time. Phone #: ###-#### Inspection requested via web by max sanders
- furnace ac coil co ok
MEC20-03069 Pressure Test7/24/20207/24/20207/24/2020 3:27:30 PMPPASS
Please call Ben to verify inspection time. Phone #: ###-#### Inspection requested via web by max sanders
- 5lb flue test ok
MEC20-02620 Final7/23/20207/24/20207/24/2020 3:10:47 PMPPASS
field super: Jason Landers
final on unit heater Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC20-02620 Pressure Test7/23/20207/24/20207/24/2020 3:10:11 PMPPASS
field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney
- 20lb underground gas test ok for backfill
MEC20-03075 Rough-in7/24/20207/24/20207/24/2020 2:54:55 PMPPASS
Phone #: ###-#### Inspection requested via web by Dave Sorensen
- ductwork and exhaust fan R/I ok
MEC20-03040 Rough-in7/24/20207/24/20207/24/2020 2:28:20 PMPFAIL
This is an unoccupied remodel. If no one is on site you can access the house from the back yard door. Phone #: ###-#### Inspection requested via web by Tony Fogg
- CSST gas line needs to be free floating inside wall. Take one support out at top of wall
- dryer vent needs to be installed in a 2x6 wall
- need information on whats happening with the old wood stove and vent
- water heater b vent needs replaced screws penetrated inner liner
MEC20-03040 Pressure Test7/24/20207/24/20207/24/2020 2:26:36 PMPPASS
This is an unoccupied remodel. If no one is on site you can access the house from the back yard door. Phone #: ###-#### Inspection requested via web by Tony Fogg
- 20lb gas test ok for water heater
MEC19-02327 Final7/24/20207/24/20207/24/2020 2:03:29 PMPPASS
Please call Bryan at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
- final ok
MEC20-02470 Final7/23/20207/24/20207/24/2020 1:46:03 PMPFAIL
Above number is employee contact for Quality. Can Google Duo at the time. Will call inspector to see if we can finalize time. Phone #: ###-#### Inspection requested via web by Ashley Van Cleave
- need to see 5lb flue test
- A/C locking caps
- need to add duct work to permit
- need to add gas pressure test to permit for upgrading meter to a 2# system
- need to support gas line and line set inside house
- A/C breaker size needs to be 40amp max
MEC20-02976 Pressure Test7/20/20207/24/20207/24/2020 1:22:57 PMAPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
- 20lb gas test ok
- tagged meter location
MEC20-02976 Rough-in7/20/20207/24/20207/24/2020 1:22:37 PMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart
- water heater b vent needs replaced screws penetrated inner liner
MEC20-02708 Final7/23/20207/24/20207/24/2020 10:25:37 AMACANC
Equipment located in garage Phone #: ###-#### Inspection requested via web by Justin Osterhout
- should have been a R/I inspection
MEC20-02708 Rough-in7/24/20207/24/20207/24/2020 10:25:23 AMAFAIL
Equipment located in garage Phone #: ###-#### Inspection requested via web by Justin Osterhout
- return duct above furnace needs sealed
- two locations of round return duct needs insulated
-bedrooms will need transfer air openings by final
MEC20-01381 Final7/23/20207/24/20207/24/2020 9:55:59 AMAPASS
call jaman to make sure someone is at the premises for inspector
Thanks Phone #: ###-#### Inspection requested via web by Manuel Canto
- final ok
MEC20-02250 Pressure Test7/23/20207/24/20207/24/2020 9:55:42 AMACANC
field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
- wrong address
MEC20-02250 Rough-in7/23/20207/24/20207/24/2020 9:55:28 AMACANC
field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
- wrong address
MEC20-03043 Rough-in7/22/20207/24/20207/24/2020 9:54:28 AMAPASS
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
- fireplace R/I ok
MEC19-04129 Final7/23/20207/24/20207/24/2020 8:55:43 AMAPASS
Screened- TJ Phone #: ###-####
- final ok
MEC20-01012 Final7/23/20207/24/20207/24/2020 8:48:45 AMAPASS
Access code is 0235 Phone #: ###-#### Inspection requested via web by Lindsey Stegemann
- final ok
MEC19-05726 Mec-Aging Inspection7/24/20207/24/20207/24/2020 8:48:27 AM FAIL
Permit has not been active since 12-20-19. Schedule inspection if work is finished.
MEC19-04394 Mec-Aging Inspection7/24/20207/24/20207/24/2020 8:47:47 AM PASS
Doc Permit Expired ok
MEC19-04394 DOC - Permit Expired7/24/20207/24/20207/24/2020 8:47:34 AMAPASS
Doc Permit Expired ok permit not active