Inspections for the day of: Tuesday, July 25, 2006.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-01429 ELE-Aging Inspection7/25/20067/25/20068/1/2006 10:07:41 AM DONE
see final
ELE06-02718 Electrical Rough-In7/25/20067/25/20067/25/2006 3:42:15 PMPPASS
mike; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr made, ric ok
ELE06-02737 Temporary Service7/25/20067/25/20067/25/2006 3:12:58 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dan Rohl t/s u/g n ok
ELE06-02704 Electrical Rough-In7/25/20067/25/20067/25/2006 1:50:21 PMPPART
ok to cover 100' u/g nw to se
ELE06-02090 Final7/25/20067/25/20067/25/2006 1:24:23 PMPFAIL
Shawn; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt called contr, left corr notice, nec 422.16(B)(2)&(4) built in dishwasher shall shall not use cord over 4' long and recpt shall be in same space, 400.5(A) seo cord ampacity 13 amps, 408.4 circuit directory shall be complete and explicit as to each circuit,314.25 each box shall have a cover, 406.5 recpt faceplates shall seat against mounting surface, 406.4 recpts shall be securely fastened in place
ELE06-02659 Permanent Service7/24/20067/25/20067/25/2006 12:01:44 PMAPASS
200amp service upgrade. Any Questions call Tate @ ###-#### Internet Inspection Request from: Andy Rose p/s o/h rec ok
ELE06-02062 Final7/24/20067/25/20067/25/2006 10:03:49 AMAPASS
Garage code 1238. Call if there are any problems Thanks-Kevin; Phone #: ###-#### Internet Inspection Request from: Kevin Blackmon ok to final
ELE06-02063 Final7/24/20067/25/20067/25/2006 9:31:51 AMAPASS
Garage code 1239 Please call me if there are any problems Thanks-Kevin; Phone #: ###-#### Internet Inspection Request from: Kevin Blackmon ok to final
ELE06-02729 Conference7/24/20067/25/20067/25/2006 8:49:06 AMADONE
###-#### lloyd talked about room and layout for recpts, subpanel and location, lighting, upstairs room, timing on permit before expires
ELE06-02718 Rough-In Permanent Service7/24/20067/25/20067/25/2006 8:08:37 AMACANC
michael; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles see p/s and also ri
ELE06-02718 Electrical Rough-In7/25/20067/25/20067/25/2006 8:08:05 AMAFAIL
michael; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called left message, left corr notice, nec 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 334.30 nm cable shall not be stapled on edge, 210.52 loft and storage room shall have recpts installed (6'-12'), BCC all make-up shall be done, address shall be posted
ELE06-02718 Permanent Service7/25/20067/25/20067/25/2006 8:04:46 AMAPASS
michael; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s u/g n ok