Inspections for the day of: Friday, July 25, 2008.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-00945 ELE-Aging Inspection7/25/20087/25/20087/30/2008 4:02:14 PM DONE
ok, see final
ESC07-01208 General Inspection7/25/20087/25/20087/25/2008 4:13:07 PMPPASS
looked ok, contractor moved trailer and sign, but said he would repost it on property
ESC08-00547 General Inspection7/25/20087/25/20087/25/2008 4:10:52 PMPPASS
looked ok
ESC07-01491 General Inspection7/25/20087/25/20087/25/2008 4:09:56 PMAPASS
looked ok
ESC08-00052 General Inspection7/25/20087/25/20087/25/2008 4:08:41 PMAPASS
looked ok
ELE08-02024 Electrical Rough-In7/24/20087/25/20087/25/2008 4:07:44 PMPCANC
Good morning Bob,
I need all of the walls for the entire tenant space inspected for cover. If you have any questions please call.
Thx. Wayne Phone #: ###-#### Internet Inspection Request from: Wayne Craig walls only ok to cover, hard lids ok to cover only
ELE08-01508 Electrical Rough-In7/25/20087/25/20087/25/2008 3:17:49 PMPPASS
Hello we are ready for 1st floor drop ceiling cover. Matt will be on site for walk thur. Thanks Phone #: ###-#### Internet Inspection Request from: Don Lustig ok to cover 1st floor ceilings only, no esc this project
ELE08-00459 Electrical Rough-In7/24/20087/25/20087/25/2008 2:20:06 PMPFAIL
Scheduled by a contractor via Hello! on 7/24/2008 at 11:43:22 AM. Contact: ###-####. called contractor, left correction notice, NEC 300.4 where subject to physical damage, shall protect cables if not 1 1/4" from face of framing members,BCC Shall complete all work before inspection, shall not use valley of steel studs to secure cable, shall have address posted
ELE08-01934 Permanent Service7/25/20087/25/20087/25/2008 12:45:20 PMPPASS
louis Phone #: ###-#### corrections made, p/s u/g n ok, no esc this project
ELE08-01934 Permanent Service7/24/20087/25/20087/25/2008 10:42:02 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Jenni Keller called contractor, equipment shall be listed suitable for use as service equipment per NEC 230.70(B), and 250.24 (A) shall have grounded service conductor connected to grounded conductor, no esc this project
ELE07-04012 Electrical Rough-In7/24/20087/25/20087/25/2008 10:03:37 AMACANC
Patrick Phone #: ###-####n see conference, too many corrections for ri
ELE07-04012 Conference7/25/20087/25/20087/25/2008 9:30:19 AMADONE
Patrick Phone #: ###-#### too many corrections for ri, talked about no screws inside box, box fill- used 2x4 framing members turned 90 degrees and 8 cubic inch boxes with 3 romex inside, no make-up done, 6' wall spacing by bedroom entry, told to mount boxes for bath sinks,
ELE08-01383 Final7/24/20087/25/20087/25/2008 9:18:49 AMAPASS
Scheduled by a contractor via Hello! on 7/24/2008 at 10:03:13 PM. Contact: ###-####. ok to final
ELE08-01357 Final7/24/20087/25/20087/25/2008 8:43:05 AMAPASS
Internet Inspection Request from: Stephen Kren ok to final, signed structural card
ELE08-02053 Permanent Service7/24/20087/25/20087/25/2008 8:05:58 AMAPASS
We connected power to the cool pedestal. Phone #: ###-#### Internet Inspection Request from: Clint Tate p/s u/g n ok, no esc this project