MEC18-02476
| Rough-in | 7/24/2018 | 7/25/2018 | 7/25/2018 4:29:32 PM | P | FAIL |
|
|
please inspect: 101,102,201,202,301,302 Phone #: ###-#### Inspection requested via web by Gary Reeves- 101 flex ducting needs strapped up/ supported -201 lineset needs supported -flex runs are being smashed by framing- flex runs need supported/ strapped up -202 flex runs need supported/ strapped up- some flex runs have large sags in them -302 a few flex runs are being smashed by their supports
|
MEC18-03614
| Final | 7/24/2018 | 7/25/2018 | 7/25/2018 3:26:13 PM | P | PASS |
|
|
Installer Jarod ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt -furnace ac coil co ok
|
MEC18-01566
| Final | 7/25/2018 | 7/25/2018 | 7/25/2018 3:01:44 PM | P | PASS |
|
|
Call mark 20 min advance to open door for inspector Thanks Phone #: ###-#### Inspection requested via web by Manuel Canto- final ok
|
MEC17-03561
| Rough-in | 7/24/2018 | 7/25/2018 | 7/25/2018 2:30:09 PM | P | PART |
|
|
approval for cover for all of first floor - Thank you! Phone #: ###-#### Inspection requested via web by Kim Adams- 1st floor R/I ok for ceiling cover
|
MEC18-00639
| Final | 7/25/2018 | 7/25/2018 | 7/25/2018 1:49:01 PM | P | PASS |
|
|
Seth Phone #: ###-####- final ok
|
MEC18-03528
| Final | 7/24/2018 | 7/25/2018 | 7/25/2018 1:31:22 PM | P | FAIL |
|
|
Please call Mike at ###-#### to coordinate. told mike I would call early afternoon Phone #: ###-#### Inspection requested via web by Sabrina DeHority- need to seal lineset penetration
|
MEC18-02985
| Rough-in | 7/24/2018 | 7/25/2018 | 7/25/2018 1:00:37 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- need to support flex runs on west side in attic space- need to seal all floor boots
|
MEC18-03623
| Pressure Test | 7/24/2018 | 7/25/2018 | 7/25/2018 12:01:13 PM | A | FAIL |
|
|
Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- gauge was at zero
|
MEC17-04823
| Mec-Aging Inspection | 7/25/2018 | 7/25/2018 | 7/25/2018 9:57:32 AM | | DONE |
|
|
called cox mechanical to schedule inspection- little old lady didnt want to let me in the home so i left a business card and told her i would call cox mech
|
MEC18-03098
| Rough-in | 7/24/2018 | 7/25/2018 | 7/25/2018 9:22:21 AM | A | PASS |
|
|
JAMES IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- R/I 15' of gas line for new RTU ok- will need to see gas reg vented above fresh air on RTU for final
|
MEC18-03098
| Pressure Test | 7/24/2018 | 7/25/2018 | 7/25/2018 9:21:07 AM | A | PASS |
|
|
JAMES IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- 60lb gas pressure test ok
|
MEC18-03414
| Final | 7/18/2018 | 7/25/2018 | 7/25/2018 8:46:42 AM | A | PASS |
|
|
please call homeowner Jason when 30 mins in route Phone #: ###-#### Inspection requested via web by Rick Montgomery - furnace ac coil co ok
|
MEC18-02476
| Rough-in | 7/24/2018 | 7/25/2018 | 7/24/2018 11:00:29 AM | A | CANC |
|
|
please Inspect 101,102,201 202, 301,302 Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|