ELE12-02104
| ELE-Aging Inspection | 7/26/2016 | 7/26/2016 | 7/27/2016 10:57:39 AM | | CANC |
|
|
too busy
|
ELE16-02295
| Final | 7/25/2016 | 7/26/2016 | 7/26/2016 2:18:42 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by CHRIS CARMINE need a engineer to give a classification of area for final
|
ELE16-01838
| Electrical Rough-In | 7/26/2016 | 7/26/2016 | 7/26/2016 1:55:44 PM | P | PASS |
|
|
Call Brandon Roninson for level 7 office building ceiling rough in. Phone #: ###-#### Inspection requested via web by Tom Betty level 7 as noted on rough-in sticker hard lid and lay in ceilings only ok cover
|
ELE15-03701
| Final | 7/26/2016 | 7/26/2016 | 7/26/2016 12:51:39 PM | P | PASS |
|
|
Call Dene with any questions Thank you Phone #: ###-#### Inspection requested via web by kim grundhauser final for temple only ok
|
ELE16-01876
| Final | 7/26/2016 | 7/26/2016 | 7/26/2016 12:27:51 PM | P | PASS |
|
|
Please call 30 min prior as no-one is on site. Phone #: ###-#### Inspection requested via web by Kerri Hamilton final ok
|
ELE15-03633
| Final | 7/26/2016 | 7/26/2016 | 7/26/2016 12:22:57 PM | P | NH |
|
|
Please call 30 min prior as no-one is on site. Phone #: ###-#### Inspection requested via web by Kerri Hamilton no body home nor access (house has security cameras and a beware of dog signs)
|
ELE16-02071
| Conference | 7/26/2016 | 7/26/2016 | 7/26/2016 11:49:05 AM | P | DONE |
|
|
Stop work order lifted. Clay with sublime electric will assume work on project.
|
ELE16-02389
| Final | 7/26/2016 | 7/26/2016 | 7/26/2016 11:43:40 AM | P | PASS |
|
|
Correction made. door code C 2743 Jerry ###-#### Phone #: ###-#### Inspection requested via web by Dave Brueggemann correction fixed final ok
|
ELE16-01703
| Final | 7/26/2016 | 7/26/2016 | 7/26/2016 11:21:05 AM | P | PASS |
|
|
final ok
|
ELE16-01225
| Final | 7/26/2016 | 7/26/2016 | 7/26/2016 11:19:45 AM | A | PASS |
|
|
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn final for temp power ok
|
ELE16-01562
| Final | 7/26/2016 | 7/26/2016 | 7/26/2016 11:17:32 AM | A | FAIL |
|
|
CODE 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn 110.7 electrical installs shall be free from shorts GFCI in kitchen in-op GFCI in garage in-op
|
ELE16-02071
| Final | 7/25/2016 | 7/26/2016 | 7/26/2016 10:20:36 AM | A | FAIL |
|
|
Homeowners should be there, please call Mike ###-#### if you have any questions. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan 210.8 all receptacles located in a bathroom shall have GFCI protection 406.4 Tamper resistant receptacles required 406.6 faceplates required STOP WORK ORDER PUT IN PLACE GC DID ELECTRICAL TRIM OUT WITH OUT LICENSES
|
ELE16-02394
| Temporary Service | 7/25/2016 | 7/26/2016 | 7/26/2016 9:36:46 AM | A | FAIL |
|
|
Darren Phone #: ###-#### 110.12(a) all unused openings shall be closed 250.53(g) all 8' of ground rod shall be in contact with the earth
|
ELE16-00519
| Final | 7/25/2016 | 7/26/2016 | 7/26/2016 9:17:11 AM | A | PASS |
|
|
###-#### Cal final ok
|
ESC15-00352
| Site Final | 7/26/2016 | 7/26/2016 | 7/26/2016 8:54:17 AM | P | PASS |
|
|
site final ok
|
ELE16-01470
| Electrical Rough-In | 7/25/2016 | 7/26/2016 | 7/26/2016 8:36:57 AM | A | PASS |
|
|
THIS IS FOR CEILING INSPECTION, WANT TO INSTALL TILES. Phone #: ###-#### Inspection requested via web by Daniel Gamboa ceilings only ok cover(will check 4-s box above bathrooms for extension and showroom outlets once tile is installed)
|