ELE06-00826
| ELE-Aging Inspection | 7/27/2006 | 7/27/2006 | 8/3/2006 3:30:04 PM | | NR |
|
|
called contr, said nr
|
ELE06-02246
| Final | 7/27/2006 | 7/27/2006 | 7/27/2006 4:03:21 PM | P | PART |
|
|
spencer; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, core and shall permit has corr notice posted. t/i ok, but need to final with core and shell.
|
ELE06-01084
| Final | 7/27/2006 | 7/27/2006 | 7/27/2006 3:55:24 PM | P | FAIL |
|
|
spencer; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, left corr notice, nec 110.22 disconnect marking shall be of sufficient durability to withstand the environment involved,250.104(A) metal water piping shall be bonded, 422.31(B) disconnects shall be installed for hot water heater and dishwasher, 352.30 rnc shall be supported within 3' of conduit body or termination
|
ELE06-01155
| Final | 7/27/2006 | 7/27/2006 | 7/27/2006 3:27:20 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Cevyn Recla ok to final
|
ELE06-01154
| Final | 7/27/2006 | 7/27/2006 | 7/27/2006 2:53:07 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Cevyn Recla ok to final
|
ELE06-02239
| Final | 7/27/2006 | 7/27/2006 | 7/27/2006 2:24:04 PM | P | PASS |
|
|
NEED FINAL INSPECTION ON NEW EQUIPMENT HOOK UP. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok to final
|
ELE06-02706
| Final | 7/25/2006 | 7/27/2006 | 7/27/2006 1:40:07 PM | P | PASS |
|
|
We 1)installed 2 new GFCI receptacles on the front patio, 2)installed 1 new receptacle in front entry & 1 at the stair landing.(6060654ew)Tech/Jason/###-####.THANKS!!!; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell called contr to close bkr openings, ok yo final
|
ELE06-02774
| Electrical Rough-In | 7/27/2006 | 7/27/2006 | 7/27/2006 1:06:29 PM | P | PASS |
|
|
Please contact Dan, thank you; Phone #: ###-#### Internet Inspection Request from: Wendy Waters ric walls only ok
|
ELE06-02622
| Final | 7/27/2006 | 7/27/2006 | 7/27/2006 11:42:44 AM | A | PASS |
|
|
Work performed by Kyle Sharp.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz ok to final
|
ELE06-02761
| Electrical Rough-In | 7/26/2006 | 7/27/2006 | 7/27/2006 10:09:25 AM | A | PASS |
|
|
need rough in on new master bedroom and bathroom. thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH called contr to put in boxes over sinks, ric ok
|
ELE06-01068
| Final | 7/26/2006 | 7/27/2006 | 7/27/2006 9:28:41 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot called contr, left corr notice, hot tub not on permit, told to change, did not open tub, no access room, nec 110.26 sufficient access and working space shall be provided about all elect equip depth and width, 210.8(A)(3) all outdoor recpts shall be gfci protected, 406.4 recepts shall be securely mounted, rest of elect ok
|
ELE06-02755
| Permanent Service | 7/26/2006 | 7/27/2006 | 7/27/2006 8:42:21 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Rohl p/s u/g n ok
|
ELE06-00460
| Electrical Rough-In | 7/26/2006 | 7/27/2006 | 7/27/2006 8:12:40 AM | A | PART |
|
|
ed - building rough-in; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to cover u/g east and se 1/2 site lighting only
|