BLD06-00363
| BLD-Conference | 7/17/2009 | 7/20/2009 | | A | |
|
|
Carrie-Ada County Assessor office-what is going on with this permit??? Phone #: ###-####
|
ESC09-00427
| General Inspection | 7/27/2009 | 7/27/2009 | 7/27/2009 4:32:37 PM | P | PASS |
|
|
|
BLD09-01129
| BLD-Foundation | 7/27/2009 | 7/27/2009 | 7/27/2009 4:32:22 PM | P | PASS |
|
|
Mike Phone #: ###-####
|
MIS09-00141
| BLD-Conference | 7/27/2009 | 7/27/2009 | 7/27/2009 2:56:19 PM | P | FAIL |
|
|
This is for a home purchase. Please contact Don Cuff at the number provided at least 1/2 hour before arrival. Thank You. Phone #: ###-#### Internet Inspection Request from: Connie LaFrainer. Provide smoke detectors in each bedrrom and downstairs, provide GFI in kitchen and bathroom, also provide outlet cover in bathroom and scrape, prime and paint fascia were needed.
|
ESC09-00268
| BMP Violation | 7/27/2009 | 7/27/2009 | 7/27/2009 2:27:21 PM | P | PASS |
|
|
Const. debries have been cleaned up.
|
ESC09-00269
| BMP Violation | 7/27/2009 | 7/27/2009 | 7/27/2009 2:26:59 PM | P | PASS |
|
|
Const. debries have been cleaned up.
|
BLD09-00735
| BLD-Framing/Rough-in | 7/27/2009 | 7/27/2009 | 7/27/2009 2:26:07 PM | P | NR |
|
|
Scheduled by a contractor via Hello! on 7/27/2009 at 8:14:06 AM. Needs elec. ri inspection first.
|
BLD09-00736
| BLD-Framing/Rough-in | 7/27/2009 | 7/27/2009 | 7/27/2009 2:25:42 PM | P | NR |
|
|
Scheduled by a contractor via Hello! on 7/27/2009 at 8:14:51 AM. Needs elec. ri inspection first.
|
BLD09-00734
| BLD-Framing/Rough-in | 7/27/2009 | 7/27/2009 | 7/27/2009 2:25:17 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 7/27/2009 at 8:13:16 AM. Strap top plates at plumbing penetrations and dryer vent. Complete lateral bracing on T08 trusses. Provide additional studs at 2 ply T07 truss at point load. ok to insul. c/n posted.
|
ESC09-00267
| BMP Violation | 7/27/2009 | 7/27/2009 | 7/27/2009 2:23:30 PM | P | PASS |
|
|
Const. debrie cleaned up.
|
BLD09-00733
| BLD-Framing/Rough-in | 7/27/2009 | 7/27/2009 | 7/27/2009 2:17:21 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 7/27/2009 at 8:12:26 AM. Provide aditional studs at T01 2ply at point load. Also provide more nails. Provide additional studs at 2ply girder bearing up stairs. ok to insul. c/n posted.
|
ESC09-00266
| BMP Violation | 7/27/2009 | 7/27/2009 | 7/27/2009 2:15:41 PM | P | PASS |
|
|
COnst. debries have been removed.
|
ESC09-00266
| BMP Violation | 7/27/2009 | 7/27/2009 | 7/27/2009 11:32:34 AM | P | CANC |
|
|
|
ESC09-00253
| General Inspection | 7/27/2009 | 7/27/2009 | 7/27/2009 11:17:42 AM | A | PASS |
|
|
|
BLD09-00707
| BLD-Framing/Rough-in | 7/24/2009 | 7/27/2009 | 7/27/2009 11:17:31 AM | A | PASS |
|
|
Ray Phone #: ###-####
|
ESC07-01018
| Random Inspection | 7/27/2009 | 7/27/2009 | 7/27/2009 11:16:25 AM | A | PASS |
|
|
|
BLD07-02129
| BLD-Final | 7/24/2009 | 7/27/2009 | 7/27/2009 11:16:11 AM | A | FAIL |
|
|
Ray ###-####//please call when on way to meet. Needs life/safety final. Sill heights at both end units are 48 inches. Needs to provide 44 inches.
|