ELE13-00903
| ELE-Aging Inspection | 7/27/2015 | 7/27/2015 | 7/30/2015 10:20:10 AM | | CANC |
|
|
too busy
|
ELE13-00908
| ELE-Aging Inspection | 7/27/2015 | 7/27/2015 | 7/30/2015 10:19:50 AM | | CANC |
|
|
Too busy
|
ELE15-01324
| Final | 7/27/2015 | 7/27/2015 | 7/27/2015 3:46:34 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Cyndi Dale Final ok
|
ELE15-02316
| Electrical Rough-In | 7/27/2015 | 7/27/2015 | 7/27/2015 3:20:47 PM | P | PASS |
|
|
Contact is Darrin Allen ###-#### Phone #: ###-#### Inspection requested via web by Scott Campbell Dividing wall rough in ok cover
|
ELE15-02028
| Final | 7/27/2015 | 7/27/2015 | 7/27/2015 2:30:49 PM | P | CANC |
|
|
JIm Phone #: ###-#### Unable to final due to power not connected yet.
|
ELE15-02028
| Permanent Service | 7/27/2015 | 7/27/2015 | 7/27/2015 2:30:29 PM | P | PASS |
|
|
JIm Phone #: ###-#### p/s u/g n ok
|
ELE15-02229
| Permanent Service | 7/27/2015 | 7/27/2015 | 7/27/2015 2:01:39 PM | P | FAIL |
|
|
Becky// please call for access Phone #: ###-#### BCC 4-05-32- Code violation not to be retained. BCC 4-05-31(C)- Unfused conductors shall not enter structure. NEC 230.70- A means shall be provided to disconnect all conductors in a building from the service entrance conductors. NEC 250.53(a)(2)- Underground metal water pipe used as grounding electode shall have a supplemental rod installed. NEC 110.3(A)- Neutral branch circuit conductor shows evidence of arcing in panel. Must have electrical contractor make corrections.
|
ELE15-02210
| Electrical Rough-In | 7/24/2015 | 7/27/2015 | 7/27/2015 1:07:58 PM | P | PASS |
|
|
We are requesting a wall rough-in inspection for Monday 7/27/15 in the afternoon. Our onsite contact is Rich @ ###-####. Thank you Phone #: ###-#### Inspection requested via web by Clint Tate West wall by J-3 to J-5 and storage area wall rough in ok cover
|
ELE15-02169
| Electrical Rough-In | 7/24/2015 | 7/27/2015 | 7/27/2015 12:12:08 PM | A | PASS |
|
|
Please call the office if you have any questions. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Attached to BLD12-00712. Underground rough in ok cover
|
ELE15-02300
| Electrical Rough-In | 7/24/2015 | 7/27/2015 | 7/27/2015 9:47:10 AM | A | PASS |
|
|
Kevin Phone #: ###-#### No solar. Low volt LED lights. bonds 4 corners, 2 at cover. Underground for pool rough in ok cover. 2 2" from patio down hill not part of this permit
|
ELE15-02308
| Rough-In Permanent Service | 7/24/2015 | 7/27/2015 | 7/27/2015 9:04:27 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI 250.24(A)- Grounded service shall have a grounding electrode installed. Unable to locate concrete encased. 300.4- Nail plates needed in room back of garage in corner and SER in kitchen area. All WUI zone soffit lights are 2 gang 2 hour fire rated boxes OK OK to foam seal
|