BLD15-02320
| BLD-Footing | 7/27/2015 | 7/27/2015 | 7/27/2015 3:49:35 PM | P | PASS |
|
|
Corwin Phone #: ###-####. Column pad footings ok.
|
BLD15-01251
| BLD-Final | 7/27/2015 | 7/27/2015 | 7/27/2015 3:18:01 PM | P | NH |
|
|
Austin Phone #: ###-####. No access.
|
BLD15-00796
| BLD-Framing/Rough-in | 7/27/2015 | 7/27/2015 | 7/27/2015 3:14:31 PM | P | FAIL |
|
|
Austin Phone #: ###-####. Complete lateral bracing on T13,17,18,19 trusses. Fireblock above ceiling at fireplace. Provide attic access downstairs. Correction notice posted. Ok to insulate.
|
BLD15-01253
| BLD-Final | 7/27/2015 | 7/27/2015 | 7/27/2015 2:34:06 PM | P | PASS |
|
|
Austin Phone #: ###-####
|
BLD15-01253
| DOC - Permit Finaled | 7/27/2015 | 7/27/2015 | 7/27/2015 2:33:35 PM | P | PASS |
|
|
|
BLD15-01704
| BLD-Wall Bracing | 7/27/2015 | 7/27/2015 | 7/27/2015 1:49:15 PM | P | PASS |
|
|
Zane Phone #: ###-####
|
BLD15-00195
| BLD-Ceiling Grid Inspection | 7/26/2015 | 7/27/2015 | 7/27/2015 10:57:31 AM | A | NR |
|
|
Call prior to going Phone #: 8809048 >> Inspection requested via mobile web by Rod Fender. Needs other trades rough in inspections first.
|
BLD15-01354
| BLD-Wall Bracing | 7/24/2015 | 7/27/2015 | 7/27/2015 10:17:42 AM | A | PASS |
|
|
Doug Phone #: ###-####
|
BLD15-01516
| BLD-Framing/Rough-in | 7/24/2015 | 7/27/2015 | 7/27/2015 10:02:22 AM | A | FAIL |
|
|
Rob Phone #: ###-####. provide additional studs under double girder truss in garage, provide h2.5 at all truss bearing locations.
|
BLD15-02033
| DOC - Permit Finaled | 7/27/2015 | 7/27/2015 | 7/27/2015 9:40:22 AM | P | PASS |
|
|
All work appeared to be done in accordance with local codes and ordinances.
|
BLD15-02033
| BLD-Conference | 7/25/2015 | 7/27/2015 | 7/27/2015 9:39:49 AM | A | DONE |
|
|
thank you Phone #: ###-#### Inspection requested via web by Sandra Daffer
|
BLD15-01530
| BLD-Energy code compliance | 7/24/2015 | 7/27/2015 | 7/27/2015 9:21:26 AM | A | PASS |
|
|
Brett Phone #: ###-####
|
BLD15-01704
| BLD-Wall Bracing | 7/24/2015 | 7/27/2015 | 7/27/2015 9:01:02 AM | A | FAIL |
|
|
Levi Phone #: ###-####. nail off sill plate with hot dip galvanized, install missing blocking.
|