PLM16-04704
| PLM-Aging Inspection | 7/27/2017 | 7/27/2017 | 7/28/2017 3:48:16 PM | | PEND |
|
|
Contractor to schedule or notify.
|
PLM16-02395
| PLM-Aging Inspection | 7/27/2017 | 7/27/2017 | 7/28/2017 2:11:25 PM | | PASS |
|
|
|
PLM16-04676
| Final | 7/27/2017 | 7/27/2017 | 7/27/2017 5:00:39 PM | P | PASS |
|
|
All work under this permit is complete
|
PLM17-00332
| Final | 7/27/2017 | 7/27/2017 | 7/27/2017 4:44:30 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Nicholas Paige. Add a cleanout cover at the drinking fountain. Install a tempering valve at each lavatory or one at the water heater set no higher than 120 degrees.
|
PLM17-02800
| Groundwork | 7/27/2017 | 7/27/2017 | 7/27/2017 3:54:04 PM | P | FAIL |
|
|
A vertical wet vent cannot come off the horizontal
|
PLM17-01493
| Plumbing Rough-in | 7/26/2017 | 7/27/2017 | 7/27/2017 3:41:35 PM | P | PASS |
|
|
Inspection requested via web by Brian Johansen
|
PLM17-02312
| Plumbing Rough-in | 7/26/2017 | 7/27/2017 | 7/27/2017 3:19:07 PM | P | PASS |
|
|
JOB # 50802 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM17-02604
| Plumbing Rough-in | 7/27/2017 | 7/27/2017 | 7/27/2017 3:00:09 PM | P | FAIL |
|
|
No pressure on the waste test. Water ok to pull test. Main bath 3" drain flat. Tighten up hangers; some are not even touching the pipe.
|
PLM17-02816
| Water and/or Sewer | 7/27/2017 | 7/27/2017 | 7/27/2017 2:25:51 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM17-02816
| Final | 7/27/2017 | 7/27/2017 | 7/27/2017 2:25:32 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM17-02800
| Groundwork | 7/26/2017 | 7/27/2017 | 7/27/2017 12:01:51 PM | A | CANC |
|
|
Access if around the back of the home, basement is completely open. Contact RIck Cornett : ###-#### Phone #: ###-#### Inspection requested via web by Rusty Karel
|
PLM17-02604
| Plumbing Rough-in | 7/26/2017 | 7/27/2017 | 7/27/2017 11:42:56 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen
|
PLM17-02798
| Final | 7/26/2017 | 7/27/2017 | 7/27/2017 11:24:25 AM | A | PASS |
|
|
New water heater installed and ready for inspection 2 carbon-monoxide Detectors installed in house. Phone #: ###-#### Inspection requested via web by Michael Webb
|
PLM17-02358
| Plumbing Rough-in | 7/26/2017 | 7/27/2017 | 7/27/2017 11:11:48 AM | A | PASS |
|
|
Tobi Wilson ###-#### Phone #: ###-#### Inspection requested via web by TOBI WLSON
|
PLM16-04144
| Plumbing Rough-in | 7/26/2017 | 7/27/2017 | 7/27/2017 10:52:38 AM | A | PART |
|
|
ROSS IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER. Building 100 walls ok to cover. RP required on the ro system for the kitchen, No solder joints allowed on an stub-outs.
|
PLM17-02803
| Sprinkler (Final) | 7/26/2017 | 7/27/2017 | 7/27/2017 10:29:14 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ken Cumpton. No access to joints; the system was backfilled prior to inspection and the shut-off riser has water standing in it and is leaching into the meter box.
|
PLM17-02525
| Final | 7/27/2017 | 7/27/2017 | 7/27/2017 10:13:44 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Nels Moore
|
PLM17-02501
| Other | 7/26/2017 | 7/27/2017 | 7/27/2017 9:51:13 AM | A | CANC |
|
|
chect new interceptor tank water test. Pass 24 hr test on outdoor tank
|