Inspections for the day of: Thursday, July 27, 2017.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-01356 Final7/26/20177/27/20177/27/2017 3:44:16 PMPPASS
Phone #: ###-#### Inspection requested via web by Andrea Creek
MEC17-03251 Final7/25/20177/27/20177/27/2017 2:47:02 PMPPASS
PLEASE CALL OUR LEAD INSTALLER SAM WHEN 30 MINS IN ROUTE- LATER PM INSPECTION WOULD BE PREFERRED IF POSSIBLE Phone #: ###-#### Inspection requested via web by Rick Montgomery
MEC17-03289 Final7/27/20177/27/20177/27/2017 2:35:49 PMPPASS
THANK YOU
INSTALLER: SCOTT T ###-#### Phone #: ###-#### Inspection requested via web by Ben Welgan
MEC17-02987 Final7/24/20177/27/20177/27/2017 2:19:16 PMPFAIL
Phone #: ###-#### Inspection requested via web by Mary LaFayette
furnace flue is backgraded before the wye
MEC17-03144 Final7/27/20177/27/20177/27/2017 1:57:23 PMPPASS
Please call Robert at ###-####. Job is ready and he will be there for pressure test as well.

Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg
MEC17-03144 Pressure Test7/27/20177/27/20177/27/2017 1:56:39 PMPPASS
Hello! Could we please schedule this for today? AM or PM. Robert is at the jobsite now and will be there all day today. His number ###-####.

Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg
5lb flue
MEC17-03037 Final7/21/20177/27/20177/27/2017 1:21:24 PMPFAIL
Please complete the inspection in the PM. Please call the homeowner, Frank and Jeannie ###-#### when you are headed to their house. Phone #: ###-#### Inspection requested via web by Kim Lithander
need to run 2nd condensate drain, armaflex needs uv protection
MEC17-03228 Final7/21/20177/27/20177/27/2017 1:21:24 PMPPASS
PLEASE CALL BRIAN, OUR INSTALLER FOR ACCESS, THANK YOU Phone #: ###-#### Inspection requested via web by Ben Welgan
MEC17-03289 Final7/26/20177/27/20177/27/2017 9:49:21 AMACANC
LATE AM IF POSSIBLE PLEASE
INSTALLER: SCOTT ###-####
THANK YOU Phone #: ###-#### >> Inspection requested via web by Ben Welgan Inspection cancelled from web by: Ben Welgan
MEC17-03289 Pressure Test7/27/20177/27/20177/27/2017 9:48:57 AMPPASS
LATE AM IF POSSIBLE PLEASE
INSTALLER: SCOTT ###-####
THANK YOU Phone #: ###-#### Inspection requested via web by Ben Welgan
5lb flue
MEC16-05473 Final7/26/20177/27/20177/27/2017 9:36:08 AMAPASS
Field Super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC17-03240 Rough-in7/26/20177/27/20177/27/2017 9:25:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Ed Ables
MEC17-03206 Rough-in7/26/20177/27/20177/27/2017 9:06:09 AMAFAIL
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak
draft stops on fireplace bvent have gaps,
floor boots need to be sealed to the floor
crawl is incomplette
theaterroom and bedroom 3 returns need to comunicate with open hallway
fresh air needs to be 8"
MEC17-03206 Pressure Test7/26/20177/27/20177/27/2017 9:03:08 AMAPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak
20 lb gas
MEC16-02915 Mec-Aging Inspection7/27/20177/27/20177/27/2017 8:08:45 AM CANC
MEC16-02897 Mec-Aging Inspection7/27/20177/27/20177/27/2017 8:07:52 AM CANC
MEC16-05464 Mec-Aging Inspection7/27/20177/27/20177/27/2017 8:07:18 AM CANC
MEC16-05464 DOC - Permit Finaled7/27/20177/27/20177/27/2017 8:07:11 AMPPASS
MEC16-05805 Mec-Aging Inspection7/27/20177/27/20177/27/2017 8:06:31 AM CANC
MEC17-01154 Final7/26/20177/27/20177/26/2017 3:02:39 PMACANC
mechanical fireplace final inspection Phone #: ###-#### >> Inspection requested via web by Dan Otero Inspection cancelled from web by: Dan Otero