Inspections for the day of: Friday, July 27, 2018.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03671 Final7/27/20187/27/20187/27/2018 4:30:54 PMPPASS
PLEASE CALL ON WAY: CHRIS ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- A/C coil co and duct work ok
MEC18-03650 Final7/26/20187/27/20187/27/2018 4:07:35 PMPPASS
Please call John to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
A/C coil co ok
MEC18-03668 Final7/27/20187/27/20187/27/2018 4:06:33 PMPPASS
Inspection requested via web by Floyd Floyd Peek- furnace ac coil co ok
MEC18-03463 Final7/24/20187/27/20187/27/2018 3:56:44 PMPFAIL
Call when you are on the way so we can meet you there Phone #: ###-#### Inspection requested via web by Dan McFate- ac coil ok- need to provide homeowner with co detectors
MEC18-03338 Final7/26/20187/27/20187/27/2018 2:33:30 PMPPASS
Homeowner has installed CO Detectors as originally agreed. Please call Josh at ###-#### with a 30 minute heads up arrival time. Thank you! Phone #: ###-#### Inspection requested via web by David or K Cole
-co detectors ok- final ok
MEC17-01126 Final7/27/20187/27/20187/27/2018 2:15:07 PMPPASS
contact person Zac ###-#### Inspection requested via web by Aaron Alandt- 4 ductless systems final ok
MEC18-03675 Rough-in7/27/20187/27/20187/27/2018 1:49:51 PMPNH
Call for access // Sean Phone #: ###-####
- no access to home called number no answer and voice mail was full
MEC18-03664 Rough-in7/26/20187/27/20187/27/2018 12:17:23 PMAPART
Phone #: ###-#### Inspection requested via web by Nicholas Paige- all ducting in uncondtioned space needs to be lined or insulated on the outside- duct seal ok
MEC18-03548 Final7/26/20187/27/20187/27/2018 11:39:41 AMAFAIL
Phone #: ###-#### Inspection requested via web by Shauna Llewellyn- need to see some form of return air in bonus room upstairs- need to seal supply boots in floor downstairs
MEC18-03502 Final7/20/20187/27/20187/27/2018 11:22:45 AMAFAIL
Please call Tess Morrow prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- need to install two new co detectors for homeowner
MEC18-03506 Final7/21/20187/27/20187/27/2018 11:04:51 AMAPASS
If possible, please call home owner one hour before at ###-#### or ###-####. Thank you Phone #: ###-#### Inspection requested via web by James Cox- A/C coil co ok
MEC18-02035 Final7/26/20187/27/20187/27/2018 10:49:02 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- mantel ok- fireplace final ok
MEC17-03561 Final7/26/20187/27/20187/27/2018 10:39:38 AMAPART
Final Inspection ; Jake is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- need air balance- two range hood vents need covered by cabinets
MEC17-01126 Mec-Aging Inspection7/27/20187/27/20187/27/2018 10:14:57 AM DONE
called western they are working on getting some info on this job
MEC18-03657 Final7/26/20187/27/20187/27/2018 9:49:55 AMAPASS
contact is Janet Cook Phone #: ###-#### Inspection requested via web by kelly Martin
-A/C coil co ok
MEC18-03665 Rough-in7/26/20187/27/20187/27/2018 9:35:21 AMAFAIL
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek
-BW vent for water heater needs 1" clearances- orange spray foam needs to be removed along with any other sealer at floor and ceiling and manufacturers firestop needs to be put in place and ceiling and floor- metal ducting in crawl and attic need to be insulated
- flex runs in attic have rips that need fixed
-flex gas line in crawl needs more supports
MEC18-01676 Final7/26/20187/27/20187/27/2018 8:46:06 AMAPASS
Call sherry 20 min in advance to meet inspector at house.
Thanks Phone #: ###-#### Inspection requested via web by Manuel Canto- final ok
MEC18-03663 Rough-in7/26/20187/27/20187/26/2018 3:23:05 PMACANC
Phone #: ###-#### >> Inspection requested via web by Brian Preece Inspection cancelled from web by: Brian Preece
MEC18-03663 Pressure Test7/26/20187/27/20187/26/2018 3:23:03 PMACANC
Phone #: ###-#### >> Inspection requested via web by Brian Preece Inspection cancelled from web by: Brian Preece