Inspections for the day of: Friday, July 28, 2017.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-02706 Pressure Test7/28/20177/28/20177/29/2017 6:49:59 AMPPASS
Inspection requested via web by Ben Welgan
MEC17-03300 Rough-in7/28/20177/28/20177/28/2017 3:47:21 PMPCANC
Rough in Inspection Phone #: ###-#### Inspection requested via web by Kim Adams
MEC17-03044 Final7/28/20177/28/20177/28/2017 3:13:00 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC17-03206 Rough-in7/28/20177/28/20177/28/2017 2:39:26 PMPPASS
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak
MEC17-02706 Rough-in7/28/20177/28/20177/28/2017 1:45:24 PMPFAIL
Inspection requested via web by Ben Welgan
need 8" fresh air
return to 2nd floor needs to be sealed
master bedroom needs trasfer
MEC17-02554 Final7/25/20177/28/20177/28/2017 1:08:59 PMAFAIL
Phone #: ###-#### Inspection requested via web by Mary LaFayette
conduit needs to be water tight conduit
MEC17-02740 Rough-in7/28/20177/28/20177/28/2017 12:55:47 PMPPASS
Phone #: ###-#### Inspection requested via web by Bryan Palmer
MEC17-02740 Pressure Test7/28/20177/28/20177/28/2017 12:55:33 PMPPASS
Phone #: ###-#### Inspection requested via web by Bryan Palmer
20,60lb gas 5lb flue x3
MEC17-02370 Final7/27/20177/28/20177/28/2017 9:47:47 AMAPASS
lock box code on last inspection. Phone #: ###-#### Inspection requested via web by Brian Preece
MEC17-02740 Rough-in7/27/20177/28/20177/28/2017 9:33:40 AMAFAIL
Phone #: ###-#### Inspection requested via web by Bryan Palmer
furnaces are correct, rough in will pass when pressure tests pass
MEC17-02740 Pressure Test7/27/20177/28/20177/28/2017 9:32:49 AMAFAIL
Phone #: ###-#### Inspection requested via web by Bryan Palmer
20lb gas pass
60lb gas fail
flue x2 fail
MEC17-02917 Rough-in7/27/20177/28/20177/28/2017 9:31:53 AMAPASS
Phone #: ###-#### Inspection requested via web by Bryan Palmer
MEC17-02917 Pressure Test7/27/20177/28/20177/28/2017 9:31:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Bryan Palmer
20 lb gas 5lb flue
MEC17-03330 Final7/27/20177/28/20177/28/2017 9:01:54 AMAFAIL
Replaced heating and air conditioning unit, gas pressure test for new line Phone #: ###-#### Inspection requested via web by Chris Wieboldt
need to run 2nd condesate drain,
armaflex needs uv protection,
need C.O. alarm for fuel fired appliance
MEC17-03330 Pressure Test7/28/20177/28/20177/28/2017 9:00:39 AMPPASS
Replaced heating and air conditioning unit, gas pressure test for new line Phone #: ###-#### Inspection requested via web by Chris Wieboldt
20lb gas
MEC17-01706 Final7/28/20177/28/20177/28/2017 8:44:53 AMPCANC
Tom is installing today shooting for later this afternoon. >> Inspection requested via web by Ben Welgan Inspection cancelled from web by: Ben Welgan
MEC17-02906 Final7/26/20177/28/20177/28/2017 8:37:52 AMAPASS
Kristin Harris may not be home. ###-####. She said go through side gate and neighbors yard to get to her AC. Re-inspection. Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC16-01373 Mec-Aging Inspection7/28/20177/28/20177/28/2017 7:25:43 AM CANC
MEC16-01373 DOC - Permit Finaled7/28/20177/28/20177/28/2017 7:25:36 AMAPASS