Inspections for the day of: Thursday, July 29, 2004.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTroy James
TitleMEC-COM/RES INSPECTOR
Phone #794-9461
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC04-01969 Rough-in7/27/20047/29/20047/29/2004 12:00:00 AMAPASS
Rick; Phone #: ###-#### Internet Inspection Request from: Mya Matheson
BLD04-00669 BLD-Final7/28/20047/29/20047/29/2004 12:00:00 AMAFAIL
shelly; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
c/n posted at kitchen 7/28/2004 3:23:20 PM
MEC04-01120 Final7/28/20047/29/20047/29/2004 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 7/28/2004 at 12:52:56 PM. Contact: ###-####.
MEC04-01562 Final7/28/20047/29/20047/29/2004 12:00:00 AMAPASS
THANK YOU; Phone #: ###-#### Internet Inspection Request from: Becky Sucher
BLD04-01356 BLD-Foundation7/28/20047/29/20047/29/2004 12:00:00 AMAPASS
mona; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD04-01189 BLD-Footing7/28/20047/29/20047/29/2004 12:00:00 AMANR
Scheduled by a contractor via Hello! on 7/28/2004 at 6:15:44 PM. Contact: ###-####.
MEC04-00568 Final7/29/20047/29/20047/29/2004 12:00:00 AMPFAIL
MEGAN; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Need to complete condensate to an approved location. Clarify if there is another furnace. The permit showed for two. 7/29/2004 2:08:06 PM
MEC04-01956 Pressure Test7/29/20047/29/20047/29/2004 12:00:00 AMPCANC
BJ; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
MEC04-01956 Final7/29/20047/29/20047/29/2004 12:00:00 AMPFAIL
BJ; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes Primary and secondary drain are not working. The additional pan under coil is collecting the condensate and will overflow on to ceiling. Called BJ and left message. Owner will shut down unit. Reinspection is required. 7/29/2004 3:35:20 PM
BLD04-01506 BLD-Footing7/29/20047/29/20047/29/2004 12:00:00 AMPPART
jim; Phone #: ###-#### Internet Inspection Request from: Annette Moore wip installing footing at column locations. Detail not shown on plans. Contractor to add footing due to the situation on site. Contractor to have special inspection on footings. 7/29/2004 2:58:41 PM
BLD04-00702 BLD-Footing7/28/20047/29/20047/29/2004 12:00:00 AMPPART
dan; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
Checked footing at grid lined 6 and K. Due to the descrepancy of original drawing and revised detail drawing, the contractor called engineer and engineer stated he wanted 6 rows of horizontal #5 bars at grid line K. Contractor will install additional bar and will be verified by special inspection. 7/29/2004 2:38:32 PM