Inspections for the day of: Friday, July 29, 2011.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-00004 ELE-Aging Inspection7/29/20117/29/20118/5/2011 11:15:34 AM DONE
stll under construction, waiting for equipment
ESC11-00125 Aging Inspection7/29/20117/29/20118/4/2011 2:42:18 PM DONE
see final
ELE11-01245 Electrical Rough-In7/29/20117/29/20117/29/2011 3:20:48 PMPPART
Contact: Spencer McLean - partial final please Phone #: ###-#### >> Inspection requested via web by Deb Gooden partial final ok missing a couple troffer fixtures
ELE11-01711 Rough-In Permanent Service7/29/20117/29/20117/29/2011 2:14:51 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by daniel bibikov NEC 300.4(A) Edge of bored holes and NM cable shall be 1 1/4 from edge of framing members NEC 334.30 Shall staple NM cable every 4 1/2 feet NEC 210.52 Any wall space of 2 ft. or more in width shall have an receptacle. Dinning room needs an box set for fixture
ELE11-01709 Electrical Rough-In7/29/20117/29/20117/29/2011 1:21:54 PMPPASS
Need ground work inspected for cover. Call Jeff ###-#### if any questions. Thanks, Andrea. Phone #: ###-#### x0000 >> Inspection requested via web by Andrea Creek rough-in ok cover trench
ELE11-01697 Permanent Service7/28/20117/29/20117/29/2011 1:07:19 PMPPASS
Electrician is Dan. The light pole is on the west side of 9th street between State & Jefferson. Permitting gave a nearby address to use. >> Inspection requested via web by joel smith p/s u/g n ok
ELE11-01698 Permanent Service7/28/20117/29/20117/29/2011 12:56:25 PMPPASS
Electrician is Dan. City streetlight is on 10th Street, 1/2 block north of main St on the West side. Permitting gave a nearby address to use. Phone #: ###-#### >> Inspection requested via web by joel smith p/s u/g n ok
ELE11-01707 Temporary Service7/29/20117/29/20117/29/2011 12:24:07 PMPPASS
THANKS BOB Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE11-01706 Temporary Service7/29/20117/29/20117/29/2011 12:20:44 PMPPASS
THANKS BOB Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE11-00152 Final7/25/20117/29/20117/29/2011 10:32:25 AMAPASS
derek Phone #: ###-#### final ok
ELE11-01655 Electrical Rough-In7/28/20117/29/20117/29/2011 10:15:19 AMAPASS
Floor Heat Inspection Phone #: ###-#### >> Inspection requested via web by Michael rough-in ok cover floor heat master bath
ELE11-01477 Final7/28/20117/29/20117/29/2011 10:01:53 AMAPASS
Final is ready. Access is through the gate to side door which will be unlocked for you. Alternate number if you can not reach Jim is Paula at ###-####. Thanks. Phone #: ###-#### >> Inspection requested via web by Paula Gratiot final ok
ELE11-01676 Electrical Rough-In7/27/20117/29/20117/29/2011 9:48:42 AMAPASS
ROUGH IN METEL STEEL WALLS FOR COVER Phone #: ###-#### >> Inspection requested via web by MARK PINNEY rough-in ok cover
ELE11-01377 Permanent Service7/28/20117/29/20117/29/2011 9:38:01 AMAPASS
Panel inspection. CJ is contact. Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut p/s u/g rec meter pac
ELE11-01687 Electrical Rough-In7/29/20117/29/20117/29/2011 9:16:37 AMPPASS
rough-in ok cover
ELE11-01687 Electrical Rough-In7/29/20117/29/20117/29/2011 9:09:47 AMAPASS
rough-in ok cover
ELE11-01687 Final7/28/20117/29/20117/29/2011 9:05:59 AMACANC
Phone #: ###-#### >> Inspection requested via web by John VanZandt
ELE11-01708 Final7/29/20117/29/20117/29/2011 8:48:54 AMAPASS
For access please call Jeff 1/2 hr prior to inspection. ###-####. >> Inspection requested via web by Terry Scott final ok add exhaust fan to equipment room