InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD15-02105 BLD-Conference7/29/20157/29/20157/30/2015 9:17:27 AMPPASS
Received soils test report. Structural fill has been tested and passed. Ok for concrete.
BLD15-00249 BLD-Footing7/28/20157/29/20157/29/2015 5:01:40 PMPPASS
Manuel Phone #: ###-####
BLD15-00237 BLD-Footing7/28/20157/29/20157/29/2015 5:00:27 PMPPASS
Manuel Phone #: ###-####
GCB14-00171 GCB-Final7/29/20157/29/20157/29/2015 3:01:24 PMPPASS
Mike ###-####. structural final only ok.
GCB15-00088 GCB-Framing7/29/20157/29/20157/29/2015 2:30:52 PMPPASS
Ron ###-####. INterior steel stud framed walls only.
BLD15-01833 BLD-Wall Bracing7/28/20157/29/20157/29/2015 1:58:09 PMPFAIL
Early afternoon - Brett Phone #: ###-####. Install missing blocks and staple missed shear panels.
BLD15-00068 BLD-Framing/Rough-in7/28/20157/29/20157/29/2015 11:53:58 AMAFAIL
Josh phone ###-####. Noted no engineering to coorect any of the wall bracing issues from previous inspection and correction notice. Portal frame nailing not complete. Provide h2.5 on interior bearing on T40, T41 and T42 trusses. Provide an approved fix from truss engineer for T46 truss. Provide (2) 2x at interior bearing for 2ply T02. Complete lateral bracing on on 2ply T47 and instsall the required bearing blocks. South bearing on trussesT17 thru T21 and J02 thru J05 aRE BEARING AT THE INCOORECT LOCATION. Provide approved fix or that the beaRING location ids ok from truss engineer. Provide blocking at interior bearing for t36 thru t39 trusses and h2.5. Fireblock the concealed space in garage above electrical panel at ceiling level. A correction notice has been posted. No insulation or exterior cover at this time.
BLD15-02105 BLD-Footing7/29/20157/29/20157/29/2015 11:45:44 AMAPART
Phone #: 2086971241 >> Inspection requested via mobile web by Heron. Footings ok. Noted that approx. 1ft. of sandy gravel was placed and compacted. Will be ok for concrete once the fill has been tested and passed and report emailed showing passing results.
GCB14-00160 GCB-Framing7/28/20157/29/20157/29/2015 9:50:16 AMAPASS
Ed ###-####
BLD15-02326 BLD-Conference7/27/20157/29/20157/29/2015 8:44:07 AMADONE
Phone #: ###-#### Inspection requested via web by Scott Smith
BLD15-02326 DOC - Permit Finaled7/29/20157/29/20157/29/2015 8:43:50 AMPPASS
All work appeared to be done in compliance with local codes and ordinances.