Inspections for the day of: Wednesday, July 3, 2013.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00629 ELE-Aging Inspection7/3/20137/3/20137/3/2013 3:29:24 PM DONE
Called left message
ELE13-01309 Final7/3/20137/3/20137/3/2013 3:20:37 PMPPASS
For access please call Ed 1/2 hr prior to inspection. ###-#### >> Inspection requested via web by Terry Scott
Final ok
ELE13-01705 Permanent Service7/2/20137/3/20137/3/2013 2:45:38 PMPPASS
clyde Phone #: ###-#### p/s u/g rec ok
ELE13-01694 Rough-In Permanent Service7/3/20137/3/20137/3/2013 2:12:47 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Greg Traudt
300.4- Nail plates needed to protect wiring from physical damage in nook,quest bath, utility, and above AV panel.
300.4 NM cable secured less than 1 1/4" from surface of framing member in m. closet, above x-mas switch, several upstairs.
210.52 General purpose receptical required in study left as entered.
334.23 NM cable shall be protected from physical damage where run less than 6' from attic access.
314.4 Metal boxes shall be bonded and grounded per artical 250.
ELE13-01693 Rough-In Permanent Service7/2/20137/3/20137/3/2013 1:13:38 PMPPASS
troy Phone #: ###-#### p/s o/h n ok
ELE13-01707 Electrical Rough-In7/2/20137/3/20137/3/2013 12:11:22 PMACANC
If not open lock box is 1931. Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot Main permit has not been picked up yet, can not perform inspection until done
ELE13-00236 Electrical Rough-In7/2/20137/3/20137/3/2013 11:52:26 AMAPASS
need a ceiling cover Phone #: ###-#### >> Inspection requested via web by Karl Paige Ceiling rough in ok cover
ELE13-01617 Electrical Rough-In7/2/20137/3/20137/3/2013 10:05:03 AMANR
don Phone #: ###-#### Service grounding and feeders not in, recepticals 18" minimum to bottom of boxes, NM support within 12" of junction boxes anddevice boxes.
ELE13-01617 Conference7/2/20137/3/20137/3/2013 9:57:13 AMADONE
don Phone #: ###-#### Discussed receptical height in garage, NM support, service grounding and feeders, and owner would like to partial final garage when ready.
ELE13-01487 Final7/2/20137/3/20137/3/2013 9:28:34 AMAFAIL
Please call Asher Sears if any questions Phone #: ###-#### >> Inspection requested via web by brad williams
400.8 Split system, flexible cord shall not pass through wall.
406.11 In all areas listed in 210.52 all 15 and 20 amp120 volt recepticals shall be tamper resistant.
ELE13-01714 Rough-In Permanent Service7/2/20137/3/20137/3/2013 9:05:29 AMAPASS
Please call Jeff if you have any questions. Thanks Phone #: ###-#### >> Inspection requested via web by Brandon Blackham Rough in ok cover p/s o/h n ok
GCE13-00061 GCE-Final7/2/20137/3/20137/3/2013 8:33:40 AMAPASS
Terry ###-#### Call for access code
Final ok
ELE13-01353 Electrical Rough-In7/1/20137/3/20137/1/2013 3:57:44 PMACANC
Phone #: ###-#### >> Inspection requested via web by Eric Schroeder Inspection cancelled from web by: Eric Schroeder