BLD13-03536
| BLD-Wall cover | 7/3/2014 | 7/3/2014 | 7/3/2014 3:20:38 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brian Stark. 2nd. floor base layer 5/8 type x for 2hr. fire wall ok.
|
BLD13-03537
| BLD-Wall cover | 7/3/2014 | 7/3/2014 | 7/3/2014 3:20:19 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brian Stark. 2nd. floor base layer 5/8 type x for 2hr. fire wall ok.
|
BLD13-03538
| BLD-Wall cover | 7/3/2014 | 7/3/2014 | 7/3/2014 3:20:03 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brian Stark. 2nd. floor base layer 5/8 type x for 2hr. fire wall ok.
|
BLD13-03539
| BLD-Wall cover | 7/3/2014 | 7/3/2014 | 7/3/2014 3:19:45 PM | P | PASS |
|
|
Firewall connections. Please inspect abour 1 pm if possible. Phone #: ###-#### Inspection requested via web by Brian Stark. 2nd. floor base layer 5/8 type x for 2hr. fire wall ok.
|
ESC14-00062
| Site Preparation | 7/3/2014 | 7/3/2014 | 7/3/2014 3:04:59 PM | P | PASS |
|
|
|
BLD14-00206
| BLD-Footing | 7/3/2014 | 7/3/2014 | 7/3/2014 3:04:37 PM | A | PASS |
|
|
Juan Phone #: ###-####
|
BLD14-01809
| BLD-Final | 7/3/2014 | 7/3/2014 | 7/3/2014 2:49:37 PM | P | NR |
|
|
Herb Phone #: ###-####. Fire/life/safety failed.
|
BLD14-00245
| BLD-Framing/Rough-in | 7/2/2014 | 7/3/2014 | 7/3/2014 2:37:27 PM | P | FAIL |
|
|
Eric Phone #: ###-####. Install additionalsquash blocking under 2ply girder truss. Install missing blocking on south shear wall. Justify missing bearing points at North A1 gable end truss. Review truss engineering for additional purlins not installed. Provide addition (2) 2x6 studs entire length of south A1 gable truss,attach to blocking and truss chords w/ 16D nails as per detail 7 A2.1. Provide web stiffmers with simpson DTC to interior wall per detail 8 A2.1. Correction notice posted.
|
BLD14-00489
| BLD-Final | 7/2/2014 | 7/3/2014 | 7/3/2014 1:49:06 PM | P | FAIL |
|
|
MIke Phone #: ###-####. Remove keyed locks and thumb tirns on interior glass doors downstairs. Remove thumb turn from upstairs exit and provide egress type hardware. Lower conduit fromrear confreance room exit. Correction notice issued.
|
BLD14-00315
| BLD-Energy code compliance | 7/3/2014 | 7/3/2014 | 7/3/2014 1:46:37 PM | P | PASS |
|
|
Dreplease call 20 minutes prior for access- Phone #: ###-####
|
GCB14-00075
| GCB-Footing | 7/2/2014 | 7/3/2014 | 7/3/2014 1:46:25 PM | P | CANC |
|
|
cancelled. no time.
|
BLD13-03265
| BLD-Final | 7/3/2014 | 7/3/2014 | 7/3/2014 1:45:56 PM | P | PASS |
|
|
not need to go out, just need a final pass since zoning signed off on 6/16/14; Brandon Hammer Phone #: ###-####. ok per 316.
|
BLD13-02455
| BLD-Final | 7/2/2014 | 7/3/2014 | 7/3/2014 11:26:07 AM | A | PASS |
|
|
Trent-please call prior Phone #: ###-####
|
BLD13-02455
| DOC - Permit Finaled | 7/3/2014 | 7/3/2014 | 7/3/2014 11:25:53 AM | P | PASS |
|
|
|
BLD14-01342
| BLD-Wall Bracing | 7/2/2014 | 7/3/2014 | 7/3/2014 11:05:01 AM | A | PASS |
|
|
Matt Phone #: ###-####
|
BLD14-01581
| BLD-Framing/Rough-in | 7/2/2014 | 7/3/2014 | 7/3/2014 10:52:56 AM | A | PASS |
|
|
chet Phone #: ###-####
|
BLD14-01581
| BLD-Energy code compliance | 7/3/2014 | 7/3/2014 | 7/3/2014 10:52:46 AM | A | PASS |
|
|
chet Phone #: ###-####
|
BLD14-01838
| BLD-Conference | 7/2/2014 | 7/3/2014 | 7/3/2014 10:24:09 AM | A | DONE |
|
|
Phone #: ###-#### Inspection requested via web by WALTER HOLLAND
|
BLD14-01838
| DOC - Permit Finaled | 7/3/2014 | 7/3/2014 | 7/3/2014 10:23:51 AM | P | PASS |
|
|
All work appeared to be in accordance with local codes and ordinances.
|
BLD14-01196
| BLD-Final | 7/2/2014 | 7/3/2014 | 7/3/2014 10:22:52 AM | A | NR |
|
|
Craig Phone #: ###-####. Fire/life/safety failed.
|
BLD14-01536
| BLD-Framing/Rough-in | 7/2/2014 | 7/3/2014 | 7/3/2014 9:53:20 AM | A | PART |
|
|
Curtis Phone #: ###-####. INterior steel stud framed walls ok. No grid. Pending elec. ri inspection.
|
GCB14-00051
| GCB-Framing | 7/2/2014 | 7/3/2014 | 7/3/2014 9:07:22 AM | A | PASS |
|
|
MIKE ###-####
|