Inspections for the day of: Monday, July 30, 2007.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01395 ELE-Aging Inspection7/30/20077/30/20078/2/2007 8:38:08 AM FAIL
called left message 110.3(B) needs manufactures grd bar kit for suzi rating conn for GEC protect #8 GEC or install #6
ELE07-02651 Permanent Service7/30/20077/30/20077/31/2007 3:05:26 PMPFAIL
perm service/final. Questions pls call Mike @ ###-#### Phone #: ###-#### Internet Inspection Request from: Heather Packer
ELE07-02652 Permanent Service7/30/20077/30/20077/30/2007 3:43:43 PMPFAIL
perm service/final. For questions pls call Mike @ ###-#### Phone #: ###-#### Internet Inspection Request from: Heather Packer corr called needs ID stickers, prefab bld has state tag on it in mech rm but wiring is messed up panet is set over jbox behind it and access is through 3" chase nipple, grd rods shall be driven vertical if possible if not 45 degrees, if not possible then layed in trench 21/2ft deep and inspected before cover
ELE07-00447 Final7/30/20077/30/20077/30/2007 2:25:39 PMPPASS
glen Phone #: ###-#### ladies rest rm ok no card
ELE07-02535 Conference7/30/20077/30/20077/30/2007 1:38:30 PMPDONE
Steve- ###-#### conf. ok needs 11/4" holes and parallel, replace 2gang boxes broken clamps, single gang broken out KO, protect cables run horizontally no wall covering, provide switch point of acces to attic, complete all makeup, move 2 gang jbox for outside light
ELE07-02672 Electrical Rough-In7/30/20077/30/20077/30/2007 12:55:12 PMPPART
Spencer; Phone #: ###-#### Internet Inspection Request from: Darla Downs
r/i ok S E corner walls only
ELE07-02562 Electrical Rough-In7/27/20077/30/20077/30/2007 11:31:43 AMANH
tom/donna Phone #: ###-#### Pat talked with owner
ELE07-02651 Final7/26/20077/30/20077/30/2007 11:31:13 AMACANC
All that was done was to put a meter on building - for questions pls call Mike w/Doherty @ ###-####. Scheduled by Heather w/Doherty Phone #: ###-#### Internet Inspection Request from: Heather Packer called needs p/s and check if prefab building has been inspected
ELE07-02652 Final7/26/20077/30/20077/30/2007 11:30:15 AMACANC
Final - all that was done was putting a meter on building. For questions pls call Mike w/Doherty @ ###-####. Scheduled by Heather w/Doherty. Phone #: ###-#### Internet Inspection Request from: Heather Packer called needs p/s and check if building is inspected note prefab building
ELE07-02549 Permanent Service7/27/20077/30/20077/30/2007 11:27:55 AMAPASS
Scheduled by a contractor via Hello! on 7/27/2007 at 3:01:16 PM. Contact: ###-####. p/s u/g new ok meter
ELE07-02548 Permanent Service7/27/20077/30/20077/30/2007 11:26:44 AMAPASS
Scheduled by a contractor via Hello! on 7/27/2007 at 2:58:27 PM. Contact: ###-####. p/s u/g new ok meter