ELE07-01397
| ELE-Aging Inspection | 7/30/2007 | 7/30/2007 | 8/3/2007 3:54:46 PM | | DONE |
|
|
see final
|
ELE07-02547
| Electrical Rough-In | 7/30/2007 | 7/30/2007 | 7/30/2007 4:05:46 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 7/30/2007 at 5:08:10 AM. Contact: ###-####. met elect, told nec art 310.15 requires conduit spacing, they will fix and recall for another day
|
ELE07-02665
| Temporary Service | 7/30/2007 | 7/30/2007 | 7/30/2007 3:52:10 PM | P | PASS |
|
|
Reinspection for Temp. Power Pole. Steve Berry is the contact person. Thank you and have a great day. Phone #: ###-#### Internet Inspection Request from: Laura Longshaw corr made, t/s u/g n ok
|
ELE07-02431
| Conference | 7/30/2007 | 7/30/2007 | 7/30/2007 2:42:39 PM | P | DONE |
|
|
steven - late afternoon - please call 1/2 hr prior to inspection Phone #: ###-#### talked about circuiting and number of outlets for addition
|
ELE07-02675
| Electrical Rough-In | 7/30/2007 | 7/30/2007 | 7/30/2007 1:50:29 PM | P | PASS |
|
|
electrician is Mike McCarrel Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer ric ok
|
ELE07-02675
| Final | 7/30/2007 | 7/30/2007 | 7/30/2007 1:40:14 PM | P | PASS |
|
|
electrician is Mike McCarrel Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer ok to final
|
ELE07-02615
| Final | 7/26/2007 | 7/30/2007 | 7/30/2007 1:11:23 PM | P | NR |
|
|
service inspection & final on pole barn Phone #: ###-#### Internet Inspection Request from: Miles Berry called, left message and notice, nh, nr, BCC all u/g shall be seen before cover, all makeup shall be seen before devices installed, shall have ri before final inspection, nec 250.52 shall use metal water pipe for gec,and 250.52(D)(2) shall augment water pipe with 2 ground rods and be inspected before cover
|
ELE07-02667
| Conference | 7/27/2007 | 7/30/2007 | 7/30/2007 11:13:24 AM | A | DONE |
|
|
lawrence- ###-#### talked about ways to do wiring to outbuilding, loads and owner said he may get prices from contractor rather doing his own work
|
ELE07-00974
| Electrical Rough-In | 7/25/2007 | 7/30/2007 | 7/30/2007 10:33:22 AM | A | PASS |
|
|
DEAN Phone #: ###-#### ric garage ok
|
ELE07-01873
| Electrical Rough-In | 7/27/2007 | 7/30/2007 | 7/30/2007 10:04:40 AM | A | PASS |
|
|
tom Phone #: ###-#### master bath, bedroom and closet only ok to cover
|
ELE07-01544
| Final | 7/27/2007 | 7/30/2007 | 7/30/2007 9:17:19 AM | A | PASS |
|
|
trent Note: if need in call trent Phone #: ###-#### ok to final, signed occ card
|
ELE07-02666
| Rough-In Permanent Service | 7/27/2007 | 7/30/2007 | 7/30/2007 8:33:11 AM | A | PASS |
|
|
brandon Phone #: ###-#### called left message, left survey, nec 334.30 shall staple nm every 4 1/2' upstairs, 210.52(A)(2) shall provide outlets in 2' wall space,kitchen, ric ok, p/s u/g n ok
|
ELE07-02665
| Temporary Service | 7/27/2007 | 7/30/2007 | 7/30/2007 7:53:44 AM | A | FAIL |
|
|
This inspection is for a temp. pole. Contact name is Steve Berry Phone #: ###-#### Internet Inspection Request from: Laura Longshaw called left corr notice,fee due, nec 250.24(B) main bonding jumper shall connect the equip grounding conductor and service disconnect enclosure to grounded conductor, BCC shall post Boise City job id sticker
|
ELE07-00467
| Electrical Rough-In | 7/27/2007 | 7/30/2007 | 7/30/2007 12:00:00 AM | P | CANC |
|
|
some can lights have for the waiting room are on special order so we need a partial for the rest of the walls and ceiling so the job can continue forward Phone #: ###-#### Internet Inspection Request from: Curtis Dunham
|