Inspections for the day of: Wednesday, July 30, 2008.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02106 Rough-In Permanent Service7/30/20087/30/20087/30/2008 3:15:34 PMPPART
removing 100 amp service and replacing it with a 200 amp service. Need inspection for the reconnect Phone #: ###-#### Internet Inspection Request from: Curtis Dunham
see added p/s needs sun/res wire guy kit shall oppose strain, address range circuit from subpanel seal KOs
ELE08-02106 Permanent Service7/30/20087/30/20087/30/2008 3:13:26 PMPPASS
removing 100 amp service and replacing it with a 200 amp service. Need inspection for the reconnect Phone #: ###-#### Internet Inspection Request from: Curtis Dunham
p/s o/h rec. ok
ELE08-02115 Final7/30/20087/30/20087/30/2008 3:12:23 PMPCANC
ron Phone #: ###-#### called need to know what ele contr wired the pump
ELE08-01313 Final7/30/20087/30/20087/30/2008 2:34:06 PMPFAIL
access # 1234 Phone #: ###-#### Internet Inspection Request from: Rick Beckman called left message talked with Perry P upstairs above garage is wired for kitchen ,
needs palns and permit that state iit is approved for that
ELE08-02099 Rough-In Permanent Service7/30/20087/30/20087/30/2008 1:42:22 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Lee Braithwait no r/i, note needs to remove gas lines below service before final, P/S o/h rec. ok
ELE08-00927 DOC - Permit Expired7/30/20087/30/20087/30/2008 1:16:50 PMPPASS
no such address
ELE08-02102 Electrical Rough-In7/29/20087/30/20087/30/2008 12:24:26 PMPPASS
keith Phone #: ###-#### ok
ESC08-00576 Site Preparation7/30/20087/30/20087/30/2008 12:24:13 PMPPART
ok
ELE08-00296 Electrical Rough-In7/29/20087/30/20087/30/2008 11:28:48 AMAPART
Phone #: ###-#### Internet Inspection Request from: Karl Paige walls anop
ELE08-01893 Final7/29/20087/30/20087/30/2008 10:21:51 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Jenni Keller ok
ESC08-00570 Random Inspection7/30/20087/30/20087/30/2008 10:21:30 AMAPASS
ok
ELE08-01054 Final7/30/20087/30/20087/30/2008 9:44:41 AMAPASS
ELE08-01020 Final7/30/20087/30/20087/30/2008 9:43:31 AMAPASS
ELE08-00097 Final7/29/20087/30/20087/30/2008 9:00:25 AMAFAIL
Homeowner has finished this himself, Martin Powell ###-#### or ###-####, I want to be done with this permit. Phone #: ###-#### Internet Inspection Request from: Andy Derrick called can't do final till homeowner secures permit for the work he did
ELE08-02113 Rough-In Permanent Service7/29/20087/30/20087/30/2008 8:57:26 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson called corr. 312.5 needs connectors for cables at panel, 210.52(B)(2) remove range hood from SABC, 362.30 strap ENT within 3ft of panel, B C C install boxes for pendant lights above island counter
ELE08-02114 Rough-In Permanent Service7/29/20087/30/20087/30/2008 8:55:04 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson called corr. 21052(B)(2) range dood shall not be on SABC, 312.5 needs connectors for cables at panel 362.30 strap ENT 3ft of panels, B.C.C. install boxes for pendant lights over island counter
ELE08-02099 Final7/29/20087/30/20087/30/2008 12:00:00 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Lee Braithwait