ELE15-01706
| Final | 7/29/2015 | 7/30/2015 | 7/30/2015 3:43:37 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Greg Idsinga 210.8- GFCI test failed when testing thermostat
|
ELE15-01900
| Final | 7/30/2015 | 7/30/2015 | 7/30/2015 3:21:44 PM | P | PASS |
|
|
Warren Phone #: ###-#### Final ok
|
ELE15-02346
| Permanent Service | 7/30/2015 | 7/30/2015 | 7/30/2015 2:48:13 PM | P | PASS |
|
|
Shane ###-#### p/s u/g rec ok
|
ELE15-02086
| Electrical Rough-In | 7/29/2015 | 7/30/2015 | 7/30/2015 2:30:07 PM | P | PASS |
|
|
Kevin Phone #: ###-#### Potting, gutter, perimeter bonding rough in ok cover
|
ELE15-01812
| Electrical Rough-In | 7/29/2015 | 7/30/2015 | 7/30/2015 12:13:12 PM | P | PASS |
|
|
underground; Tate Phone #: ###-#### No underground. Concrete encased electrode N.W. corner rough in ok cover
|
ELE15-01921
| Final | 7/30/2015 | 7/30/2015 | 7/30/2015 11:44:01 AM | P | FAIL |
|
|
code is 2468 Phone #: ###-#### Inspection requested via web by Darryn Coburn 300.4- NM cable shall be protected from physical damage where passing thru hole in fireplace wall. 406.6- Faceplates shall be installed in complete installations. M. bath vanity and broke plate in garage.
|
ELE15-02356
| Temporary Service | 7/30/2015 | 7/30/2015 | 7/30/2015 10:56:55 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE15-02212
| Temporary Service | 7/30/2015 | 7/30/2015 | 7/30/2015 10:56:20 AM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn 250.24(C)- A grounded conductor shall be routed with the ungrounded conductors and shall be connected to the grounded conductor terminal or bus.
|
ELE15-01287
| Electrical Rough-In | 7/30/2015 | 7/30/2015 | 7/30/2015 10:22:08 AM | A | PASS |
|
|
wall cover Phone #: ###-#### Inspection requested via web by Karl Paige Bath and offices walls and hardlid rough in ok cover
|
ELE15-01289
| Electrical Rough-In | 7/30/2015 | 7/30/2015 | 7/30/2015 10:19:34 AM | A | PASS |
|
|
wall cover Phone #: ###-#### Inspection requested via web by Karl Paige Baths and 2 offices walls and hardlid rough in ok cover
|
ELE15-01285
| Permanent Service | 7/30/2015 | 7/30/2015 | 7/30/2015 10:15:35 AM | A | PASS |
|
|
electrical service meter pac Phone #: ###-#### Inspection requested via web by Karl Paige House service. p/s u/g n ok
|
ELE15-02342
| Electrical Rough-In | 7/29/2015 | 7/30/2015 | 7/30/2015 9:04:05 AM | A | PASS |
|
|
Inspection requested via web by Rowdy Monroe Garage rough in ok cover
|
ELE15-02343
| Electrical Rough-In | 7/29/2015 | 7/30/2015 | 7/30/2015 8:45:30 AM | A | PASS |
|
|
Inspection requested via web by Rowdy Monroe Garage rough in ok cover
|
ELE12-01498
| ELE-Aging Inspection | 7/30/2015 | 7/30/2015 | 7/30/2015 8:32:41 AM | | DONE |
|
|
Still under construction
|
ELE15-02207
| Final | 7/29/2015 | 7/30/2015 | 7/29/2015 1:35:07 PM | A | CANC |
|
|
Shane is the contact for Doherty ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates This wil be rescheduled when mill work is in
|