Inspections for the day of: Monday, July 30, 2018.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM18-02590 Plumbing Rough-in7/27/20187/30/20187/30/2018 3:50:18 PMPPASS
JOB # 51670 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM18-01879 Plumbing Rough-in7/30/20187/30/20187/30/2018 3:46:07 PMPPASS
PLM18-01879 Water and/or Sewer7/30/20187/30/20187/30/2018 3:45:43 PMPCANC
PLM18-02641 Plumbing Rough-in7/27/20187/30/20187/30/2018 3:44:55 PMPPASS
JOB # 51698 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM18-03190 Sprinkler (Final)7/30/20187/30/20187/30/2018 3:09:59 PMPPASS
Phone #: ###-#### Inspection requested via web by Darrell Roark
PLM18-03176 Groundwork7/27/20187/30/20187/30/2018 3:00:44 PMPPART
JOHN IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER.
South half groundwork ok to cover trenches. Inspect topout after footings.
PLM18-03129 Other7/30/20187/30/20187/30/2018 2:59:52 PMPPASS
passed 24 hr test
PLM18-01702 Final7/30/20187/30/20187/30/2018 2:37:40 PMPPART
CHRIS IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER.
Provide a safety restraint for the water heaters
PLM18-02570 Groundwork7/30/20187/30/20187/30/2018 2:24:27 PMPPASS
PLM18-02770 Water Softner Final7/26/20187/30/20187/30/2018 2:06:11 PMPPASS
Please call Debbie on the way so that she can be home when you arrive. Phone #: ###-#### Inspection requested via web by Rick Martinez
PLM18-02476 Final7/25/20187/30/20187/30/2018 1:42:19 PMPFAIL
Phone #: ###-#### Inspection requested via web by Mary LaFayette.
1. The softener drain must have an air gap at the termination end.
2. The drain must run full size unless proof in writing from the manufacturer.
PLM17-04190 PLM-Aging Inspection7/30/20187/30/20187/30/2018 11:42:47 AM PASS
PLM17-04190 DOC - Permit Expired7/30/20187/30/20187/30/2018 11:42:36 AMPPASS
no action by contractor. could not do visual
PLM18-03205 Final7/27/20187/30/20187/30/2018 11:41:48 AMAFAIL
Please let customer; Larsen Graff know when you are headed his way. Phone # ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby.
Pipe the t&p and pan drain out of the crawl.
Verify drains have grade
PLM18-01590 Final7/27/20187/30/20187/30/2018 11:16:52 AMAPASS
#51463 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM18-01629 Final7/27/20187/30/20187/30/2018 10:53:10 AMAPASS
Phone #: ###-#### Inspection requested via web by Brian Johansen
PLM18-03214 Final7/27/20187/30/20187/30/2018 10:40:46 AMAPASS
Phone #: ###-#### Inspection requested via web by Terri Rogers
PLM17-02102 PLM-Aging Inspection7/30/20187/30/20187/30/2018 10:23:04 AM PASS
wip
PLM18-03218 Water and/or Sewer7/30/20187/30/20187/30/2018 10:09:40 AMAPASS
Phone #: ###-#### Inspection requested via web by matt ford
PLM18-02570 Groundwork7/27/20187/30/20187/30/2018 10:09:26 AMANR
BRAD IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
PLM18-03218 DOC - Permit Finaled7/30/20187/30/20187/30/2018 10:05:39 AMPPASS
PLM18-03129 Other7/27/20187/30/20187/30/2018 9:40:21 AMACANC
complete 24 hr test. this afternoon
PLM18-01879 Plumbing Rough-in7/27/20187/30/20187/30/2018 9:38:39 AMAPART
RYAN IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER.
OK to cover wall in the rr/north end.
The cpvc needs to be hung at 32" on all horizontal lines.
MIS18-00283 PLM-Conference7/27/20187/30/20187/30/2018 9:38:37 AMAPASS
Per Dan E. Installing sprinkler backflow without permit Phone #: ###-####. ho will pull permit