Inspections for the day of: Monday, July 30, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-01153 Final7/30/20187/30/20187/30/2018 4:53:48 PMPFAIL
Bj 5730755 Inspection requested via web by william kerwin- cant use flex for range hood venting- also cant find make up air vent termination
MEC18-03723 Pressure Test7/30/20187/30/20187/30/2018 4:51:42 PMPPASS
Fritz Phone #: ###-####- 20lb gas pressure test ok
MEC18-03674 Final7/30/20187/30/20187/30/2018 2:35:23 PMPPASS
Please call on way: Blake ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- furnace ac coil co ok
MEC17-02855 Final7/26/20187/30/20187/30/2018 2:09:49 PMPPASS
Phone #: ###-#### Inspection requested via web by Nicholas Paige- final ok
MEC18-03548 Final7/30/20187/30/20187/30/2018 1:54:42 PMPPASS
This is for a reinspection Phone #: ###-#### Inspection requested via web by Shauna Llewellyn- supply boots sealed- final ok
MEC18-02476 Rough-in7/27/20187/30/20187/30/2018 12:21:21 PMAFAIL
please inspect 103,104,203,204,303,304 Phone #: ###-#### Inspection requested via web by Gary Reeves
104- duct seal on return at furnace
204- supply flex being smashed in mech room- return pipe needs sealed at end cap- supply duct needs sealed at end cap
303- supply flex run needs fixed its being smashed - return end cap also needs to be sealed
304- supply run into living room needs support strap adjusted as to not smash flex
MEC18-03447 Pressure Test7/27/20187/30/20187/30/2018 11:21:33 AMAPASS
Gas pressure test. Please call ###-#### before arrival. Phone #: ###-#### Inspection requested via web by chris mcdaniel
- 20lb gas pressure test ok- for final make sure that flex gas line in crawl has no exposed CSST stainless. at the double vavles there was some exposed stainless that needs wrapped in approved coating
MEC18-03585 Final7/28/20187/30/20187/30/2018 10:52:04 AMAPASS
breaker is changed Phone #: ###-#### Inspection requested via web by Krista Boss
- breaker size ok- final ok
MEC18-03665 Rough-in7/29/20187/30/20187/30/2018 10:40:17 AMAPART
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek- Need to see approved firestops put in place at ceiling and floor for water heater bw flue vent
MEC18-03047 Final7/27/20187/30/20187/30/2018 9:47:35 AMAPASS
Tide in new gas line to meter on east side of house, final inspection. Phone #: ###-#### Inspection requested via web by Gary Duncan- gasline tie in ok- range hood ok- final ok
MEC18-03675 Rough-in7/27/20187/30/20187/30/2018 12:00:00 AMACANC
Shaun or Steve ###-#### Phone #: ###-####5
MIS18-00276 MEC-Conference7/25/20187/30/20187/30/2018 12:00:00 AMPPEND
as per Tom Saunders major life safety issues
- waiting on BLD inspector to check building classification for cabinet shop