MEC18-01153
| Final | 7/30/2018 | 7/30/2018 | 7/30/2018 4:53:48 PM | P | FAIL |
|
|
Bj 5730755 Inspection requested via web by william kerwin- cant use flex for range hood venting- also cant find make up air vent termination
|
MEC18-03723
| Pressure Test | 7/30/2018 | 7/30/2018 | 7/30/2018 4:51:42 PM | P | PASS |
|
|
Fritz Phone #: ###-####- 20lb gas pressure test ok
|
MEC18-03674
| Final | 7/30/2018 | 7/30/2018 | 7/30/2018 2:35:23 PM | P | PASS |
|
|
Please call on way: Blake ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- furnace ac coil co ok
|
MEC17-02855
| Final | 7/26/2018 | 7/30/2018 | 7/30/2018 2:09:49 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Nicholas Paige- final ok
|
MEC18-03548
| Final | 7/30/2018 | 7/30/2018 | 7/30/2018 1:54:42 PM | P | PASS |
|
|
This is for a reinspection Phone #: ###-#### Inspection requested via web by Shauna Llewellyn- supply boots sealed- final ok
|
MEC18-02476
| Rough-in | 7/27/2018 | 7/30/2018 | 7/30/2018 12:21:21 PM | A | FAIL |
|
|
please inspect 103,104,203,204,303,304 Phone #: ###-#### Inspection requested via web by Gary Reeves 104- duct seal on return at furnace 204- supply flex being smashed in mech room- return pipe needs sealed at end cap- supply duct needs sealed at end cap 303- supply flex run needs fixed its being smashed - return end cap also needs to be sealed 304- supply run into living room needs support strap adjusted as to not smash flex
|
MEC18-03447
| Pressure Test | 7/27/2018 | 7/30/2018 | 7/30/2018 11:21:33 AM | A | PASS |
|
|
Gas pressure test. Please call ###-#### before arrival. Phone #: ###-#### Inspection requested via web by chris mcdaniel - 20lb gas pressure test ok- for final make sure that flex gas line in crawl has no exposed CSST stainless. at the double vavles there was some exposed stainless that needs wrapped in approved coating
|
MEC18-03585
| Final | 7/28/2018 | 7/30/2018 | 7/30/2018 10:52:04 AM | A | PASS |
|
|
breaker is changed Phone #: ###-#### Inspection requested via web by Krista Boss - breaker size ok- final ok
|
MEC18-03665
| Rough-in | 7/29/2018 | 7/30/2018 | 7/30/2018 10:40:17 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek- Need to see approved firestops put in place at ceiling and floor for water heater bw flue vent
|
MEC18-03047
| Final | 7/27/2018 | 7/30/2018 | 7/30/2018 9:47:35 AM | A | PASS |
|
|
Tide in new gas line to meter on east side of house, final inspection. Phone #: ###-#### Inspection requested via web by Gary Duncan- gasline tie in ok- range hood ok- final ok
|
MEC18-03675
| Rough-in | 7/27/2018 | 7/30/2018 | 7/30/2018 12:00:00 AM | A | CANC |
|
|
Shaun or Steve ###-#### Phone #: ###-####5
|
MIS18-00276
| MEC-Conference | 7/25/2018 | 7/30/2018 | 7/30/2018 12:00:00 AM | P | PEND |
|
|
as per Tom Saunders major life safety issues - waiting on BLD inspector to check building classification for cabinet shop
|