Inspections for the day of: Tuesday, July 30, 2019.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02173 Final7/30/20197/30/20197/30/2019 2:02:42 PMPFAIL
The home will be unlocked and is vacant. In the case it is not unlocked, the code is 1313. Call Jason with any questions at ###-#### Phone #: ###-#### Inspection requested via web by Clayton Morgan 406.12 Receps shall be Tamp resistant. (2 GFCI's in back splash)
ELE19-02017 Electrical Rough-In7/29/20197/30/20197/30/2019 11:28:20 AMAFAIL
Jim Phone #: ###-####
240.4D4 Max ampacity for 14 awg wire is 15amps. (Minisplit has a 16.5 amp minimum.)
300.4A1 Wire through bored holes less than 1 1/4in from face shall be protected.(Nail plates need in misc. places on top plates)
314.16. Box fill. (Master bed homerun box overfilled. Need 21.5 min box.)
210.63 A/C equipment recep. (Service recep needed within 25ft of Mini split condenser)
ELE18-03962 Rough-In Permanent Service7/30/20197/30/20197/30/2019 11:05:20 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson rough in ok p/s u/g n ok
ELE18-03961 Rough-In Permanent Service7/30/20197/30/20197/30/2019 11:04:22 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson rough in ok p/s u/g n ok
ELE19-01869 Final7/30/20197/30/20197/30/2019 10:36:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
ELE19-01868 Final7/30/20197/30/20197/30/2019 10:35:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
ELE19-02802 Temporary Service7/30/20197/30/20197/30/2019 9:50:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson t/s u/g n ok
ELE19-02803 Temporary Service7/30/20197/30/20197/30/2019 9:50:21 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson t/s u/g n ok
ELE19-02811 Electrical Rough-In7/29/20197/30/20197/30/2019 9:42:08 AMAPASS
Underground. Phone #: ###-#### Inspection requested via web by Sean DeLacy Underground from panel to back of property only ok to cover
ELE19-02753 Final7/29/20197/30/20197/30/2019 9:08:54 AMANR
Lock box is on back door near pedistal. Combo is 6781 Phone #: ###-#### Inspection requested via web by Nick Avery Need to recall for final after service has been energized
ELE19-02753 Rough-In Permanent Service7/30/20197/30/20197/30/2019 9:08:45 AMAPASS
Lock box is on back door near pedistal. Combo is 6781 Phone #: ###-#### Inspection requested via web by Nick Avery Underground ok to cover. p/s u/g rec ok