ELE19-02173
| Final | 7/30/2019 | 7/30/2019 | 7/30/2019 2:02:42 PM | P | FAIL |
|
|
The home will be unlocked and is vacant. In the case it is not unlocked, the code is 1313. Call Jason with any questions at ###-#### Phone #: ###-#### Inspection requested via web by Clayton Morgan 406.12 Receps shall be Tamp resistant. (2 GFCI's in back splash)
|
ELE19-02017
| Electrical Rough-In | 7/29/2019 | 7/30/2019 | 7/30/2019 11:28:20 AM | A | FAIL |
|
|
Jim Phone #: ###-#### 240.4D4 Max ampacity for 14 awg wire is 15amps. (Minisplit has a 16.5 amp minimum.) 300.4A1 Wire through bored holes less than 1 1/4in from face shall be protected.(Nail plates need in misc. places on top plates) 314.16. Box fill. (Master bed homerun box overfilled. Need 21.5 min box.) 210.63 A/C equipment recep. (Service recep needed within 25ft of Mini split condenser)
|
ELE18-03962
| Rough-In Permanent Service | 7/30/2019 | 7/30/2019 | 7/30/2019 11:05:20 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson rough in ok p/s u/g n ok
|
ELE18-03961
| Rough-In Permanent Service | 7/30/2019 | 7/30/2019 | 7/30/2019 11:04:22 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson rough in ok p/s u/g n ok
|
ELE19-01869
| Final | 7/30/2019 | 7/30/2019 | 7/30/2019 10:36:15 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE19-01868
| Final | 7/30/2019 | 7/30/2019 | 7/30/2019 10:35:47 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE19-02802
| Temporary Service | 7/30/2019 | 7/30/2019 | 7/30/2019 9:50:47 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson t/s u/g n ok
|
ELE19-02803
| Temporary Service | 7/30/2019 | 7/30/2019 | 7/30/2019 9:50:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson t/s u/g n ok
|
ELE19-02811
| Electrical Rough-In | 7/29/2019 | 7/30/2019 | 7/30/2019 9:42:08 AM | A | PASS |
|
|
Underground. Phone #: ###-#### Inspection requested via web by Sean DeLacy Underground from panel to back of property only ok to cover
|
ELE19-02753
| Final | 7/29/2019 | 7/30/2019 | 7/30/2019 9:08:54 AM | A | NR |
|
|
Lock box is on back door near pedistal. Combo is 6781 Phone #: ###-#### Inspection requested via web by Nick Avery Need to recall for final after service has been energized
|
ELE19-02753
| Rough-In Permanent Service | 7/30/2019 | 7/30/2019 | 7/30/2019 9:08:45 AM | A | PASS |
|
|
Lock box is on back door near pedistal. Combo is 6781 Phone #: ###-#### Inspection requested via web by Nick Avery Underground ok to cover. p/s u/g rec ok
|