MEC20-00904
| Final | 7/30/2020 | 7/30/2020 | 7/30/2020 3:36:06 PM | P | PASS |
|
|
Please use code 4888 for entry Phone #: ###-#### Inspection requested via web by Sarah Small- final ok
|
MEC20-02954
| Final | 7/27/2020 | 7/30/2020 | 7/30/2020 3:04:13 PM | P | PASS |
|
|
Please call Dennis when heading to jobsite Phone #: ###-#### Inspection requested via web by Dennis Fox- a/c coil co ok- condenser on roof- pics of coil in closet from installer onsite
|
MEC20-03142
| Rough-in | 7/30/2020 | 7/30/2020 | 7/30/2020 2:32:46 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- need to fix all rips and tears in arma flex in attic bare copper can be seen 2- low voltage wire laying on water heater b vent needs to support 3- gas gauge wont zero out 4- need to resubmit man j for equipment installed has carrier man shows payne and have approved one onsite for next inspection 5- range duct oval thru ceiling 6- all registers in ceiling need sealed 7- need to support exhaust ducting from master bath in attic of den/office 8- supply and return ducting in chase need metal installed where penetrates wall and attic and draftstop with fire caulk- flex duct can not run thru floors, walls or ceilings per bld code 9- bath exhaust 2nd floor needs supported 10-fresh air needs to be ran in 8" not 6" per man j
left notice window by fireplace
|
MEC20-03142
| Pressure Test | 7/30/2020 | 7/30/2020 | 7/30/2020 2:27:04 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge wont zero out
|
MEC20-02011
| Rough-in | 7/30/2020 | 7/30/2020 | 7/30/2020 2:00:18 PM | P | PART |
|
|
Mechanical Grid Inspection for Kitchen As Soon As Possible. Please Contact Karl With Any Questions. ###-####. Phone #: ###-#### Inspection requested via web by Karl Hestekin- need 18" clear to top of hood for MAU ducting thats flexed will need to be hard piped- ok for ceiling tiles in kitchen excluding where work will take place- went over with GC and installer and talked to Karl by phone
|
MEC20-03124
| Final | 7/27/2020 | 7/30/2020 | 7/30/2020 1:18:03 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC20-00225
| Rough-in | 7/30/2020 | 7/30/2020 | 7/30/2020 12:41:35 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Amanda Farnsworth- seal on duct west side of corridor from north to south ok excluding corriidor, rm 222h 222g 222f and hard lids- ok to insulate- call in when rooms, corridor and all hard lids ready
|
MEC20-03055
| DOC - Permit Finaled | 7/30/2020 | 7/30/2020 | 7/30/2020 11:41:03 AM | A | PASS |
|
|
final ok- pics sent via text
|
MEC20-03186
| Final | 7/29/2020 | 7/30/2020 | 7/30/2020 10:48:12 AM | A | PASS |
|
|
Call Neil for access ###-#### or Joey ###-#### Phone #: ###-#### Inspection requested via web by Joey Hickman- R/I ok bath exhausts- final ok- card signed
|
MEC20-03187
| Final | 7/29/2020 | 7/30/2020 | 7/30/2020 10:47:00 AM | A | PASS |
|
|
Call Neil for access ###-#### or Joey ###-#### Phone #: ###-#### Inspection requested via web by Joey Hickman- R/I bath exhaust ok- final ok- card signed
|
MEC20-01527
| Final | 7/29/2020 | 7/30/2020 | 7/30/2020 10:01:16 AM | A | PASS |
|
|
Call for access to the house Phone #: ###-#### Inspection requested via web by Bob Ferrin
|
MEC20-02456
| Pressure Test | 7/29/2020 | 7/30/2020 | 7/30/2020 9:33:20 AM | A | PASS |
|
|
Contact: Robert Church ###-#### Phone #: ###-#### Inspection requested via web by Brent Lacy- 60lb gas pass tagged meter location
|
MEC20-03055
| Final | 7/24/2020 | 7/30/2020 | 7/30/2020 8:56:40 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- secondary drain needs wet switch or ran to garage floor- primary drain open tee need extended up higher than secondary drain add 4" to it
|
MEC20-02011
| Rough-in | 7/30/2020 | 7/30/2020 | 7/30/2020 8:30:31 AM | P | CANC |
|
|
Grid Inspection Needed at Costa Vida as soon as possible.Please contact Karl with any questions ###-#### Phone #: ###-#### >> Inspection requested via web by Karl Hestekin Inspection cancelled from web by: Karl Hestekin
|
MEC20-02315
| Rough-in | 7/29/2020 | 7/30/2020 | 7/30/2020 8:26:49 AM | A | PASS |
|
|
cover inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok ducts supported- will need to see hood installed and ducting ran
|
MEC20-00002
| Mec-Aging Inspection | 7/30/2020 | 7/30/2020 | 7/30/2020 8:00:18 AM | | CANC |
|
|
WIP
|
MEC19-05835
| Mec-Aging Inspection | 7/30/2020 | 7/30/2020 | 7/30/2020 7:59:36 AM | | FAIL |
|
|
contractor needs to schedule inspection- permit no active since issued- permit will expire next aging if no activity
|