Inspections for the day of: Thursday, July 30, 2020.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00904 Final7/30/20207/30/20207/30/2020 3:36:06 PMPPASS
Please use code 4888 for entry Phone #: ###-#### Inspection requested via web by Sarah Small- final ok
MEC20-02954 Final7/27/20207/30/20207/30/2020 3:04:13 PMPPASS
Please call Dennis when heading to jobsite Phone #: ###-#### Inspection requested via web by Dennis Fox- a/c coil co ok- condenser on roof- pics of coil in closet from installer onsite
MEC20-03142 Rough-in7/30/20207/30/20207/30/2020 2:32:46 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- need to fix all rips and tears in arma flex in attic bare copper can be seen
2- low voltage wire laying on water heater b vent needs to support
3- gas gauge wont zero out
4- need to resubmit man j for equipment installed has carrier man shows payne and have approved one onsite for next inspection
5- range duct oval thru ceiling
6- all registers in ceiling need sealed
7- need to support exhaust ducting from master bath in attic of den/office
8- supply and return ducting in chase need metal installed where penetrates wall and attic and draftstop with fire caulk- flex duct can not run thru floors, walls or ceilings per bld code
9- bath exhaust 2nd floor needs supported
10-fresh air needs to be ran in 8" not 6" per man j

left notice window by fireplace
MEC20-03142 Pressure Test7/30/20207/30/20207/30/2020 2:27:04 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge wont zero out
MEC20-02011 Rough-in7/30/20207/30/20207/30/2020 2:00:18 PMPPART
Mechanical Grid Inspection for Kitchen As Soon As Possible. Please Contact Karl With Any Questions. ###-####. Phone #: ###-#### Inspection requested via web by Karl Hestekin- need 18" clear to top of hood for MAU ducting thats flexed will need to be hard piped- ok for ceiling tiles in kitchen excluding where work will take place- went over with GC and installer and talked to Karl by phone
MEC20-03124 Final7/27/20207/30/20207/30/2020 1:18:03 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
MEC20-00225 Rough-in7/30/20207/30/20207/30/2020 12:41:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Amanda Farnsworth- seal on duct west side of corridor from north to south ok excluding corriidor, rm 222h 222g 222f and hard lids- ok to insulate- call in when rooms, corridor and all hard lids ready
MEC20-03055 DOC - Permit Finaled7/30/20207/30/20207/30/2020 11:41:03 AMAPASS
final ok- pics sent via text
MEC20-03186 Final7/29/20207/30/20207/30/2020 10:48:12 AMAPASS
Call Neil for access ###-#### or Joey ###-#### Phone #: ###-#### Inspection requested via web by Joey Hickman- R/I ok bath exhausts- final ok- card signed
MEC20-03187 Final7/29/20207/30/20207/30/2020 10:47:00 AMAPASS
Call Neil for access ###-#### or Joey ###-#### Phone #: ###-#### Inspection requested via web by Joey Hickman- R/I bath exhaust ok- final ok- card signed
MEC20-01527 Final7/29/20207/30/20207/30/2020 10:01:16 AMAPASS
Call for access to the house Phone #: ###-#### Inspection requested via web by Bob Ferrin
MEC20-02456 Pressure Test7/29/20207/30/20207/30/2020 9:33:20 AMAPASS
Contact: Robert Church ###-#### Phone #: ###-#### Inspection requested via web by Brent Lacy- 60lb gas pass tagged meter location
MEC20-03055 Final7/24/20207/30/20207/30/2020 8:56:40 AMAFAIL
Phone #: ###-#### Inspection requested via web by Mary LaFayette- secondary drain needs wet switch or ran to garage floor- primary drain open tee need extended up higher than secondary drain add 4" to it
MEC20-02011 Rough-in7/30/20207/30/20207/30/2020 8:30:31 AMPCANC
Grid Inspection Needed at Costa Vida as soon as possible.Please contact Karl with any questions ###-#### Phone #: ###-#### >> Inspection requested via web by Karl Hestekin Inspection cancelled from web by: Karl Hestekin
MEC20-02315 Rough-in7/29/20207/30/20207/30/2020 8:26:49 AMAPASS
cover inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok ducts supported- will need to see hood installed and ducting ran
MEC20-00002 Mec-Aging Inspection7/30/20207/30/20207/30/2020 8:00:18 AM CANC
WIP
MEC19-05835 Mec-Aging Inspection7/30/20207/30/20207/30/2020 7:59:36 AM FAIL
contractor needs to schedule inspection- permit no active since issued- permit will expire next aging if no activity