Inspections for the day of: Tuesday, July 31, 2018.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-02826 Electrical Rough-In7/31/20187/31/20187/31/2018 2:41:52 PMPPASS
Donny-please call 30 minute prior you will need Donny to meet for access Phone #: ###-####
Misc receptacles fished in TV, ect. kitchen remodel rough in ok cover
ELE18-01333 Electrical Rough-In7/31/20187/31/20187/31/2018 1:43:37 PMPNH
Rough in on built in entertainment center. Access code is 5488, house is vacant. Electrician is Tony Newland 208.447.7612 Inspection requested via web by Clint Tate No access, lock box number did not produce a key. Called contact and left message to recall when accessible.
ELE18-02893 Electrical Rough-In7/31/20187/31/20187/31/2018 1:11:15 PMPPASS
rough cover Phone #: ###-#### Inspection requested via web by Matthew White
Discussed 4' wall space created by bath wall. owner informed of a closet that is going to be built here. If 24" of wall space exists receptacle will be required, if under 24" receptacle not required. Back west utility and bathroom rough in ok cover.
ELE18-02894 Conference7/31/20187/31/20187/31/2018 11:00:25 AMPDONE
confirmation on application Phone #: ###-#### Inspection requested via web by Robert Carter
Discussed type of lighting used for plenum above a 1 hr fire rated ceiling. All penetrations shall have at least a 1 hr fire rated box installed and all wiring installed in plenum area shall be plenum rated. Halo recess cans do ot have a fire rating. Contactor looking at a small LED surface mount luminaire that mounts to 2 hr rated remodel electrical box.
ELE18-02792 Final7/30/20187/31/20187/31/2018 10:35:33 AMANR
Phone #: ###-#### Inspection requested via web by Michael Hobson
Owner confused when to request final. Wall cover not installed yet. Will recall when room ready to use for final.
ELE18-01306 Electrical Rough-In7/30/20187/31/20187/31/2018 9:53:13 AMANR
Job Supervisor : Jay Karel Phone #: ###-#### Inspection requested via web by Laurie Hoelscher
Not scheduled to install until 8/3/18. Will recall when ready.
ELE18-02878 Temporary Service7/30/20187/31/20187/31/2018 9:43:30 AMAFAIL
Call Mikel with any questions ###-#### Phone #: ###-#### Inspection requested via web by Bonnie Page
Receptacles other than 120 volt shall have GFCI protection. 250.
ELE18-02883 Temporary Service7/30/20187/31/20187/31/2018 9:21:42 AMAFAIL
Mark Phone #: ###-####
400.5- Ampacity shall not exeed rating of flexible cords. 35 amps for #8, 45 amps for #6. 60 amp breakers installed.
590.6(B)- Receptacles other than 120 volt shall have GFCI protection.
ELE18-02867 Rough-In Permanent Service7/30/20187/31/20187/31/2018 8:55:01 AMAPASS
Please schedule as early as possible. Thanks Phone #: ###-#### Inspection requested via web by Alan Lusk
rough in ok cover p/s u/g n ok
ELE18-01550 Rough-In Permanent Service7/30/20187/31/20187/31/2018 12:00:00 AMAPASS
Please schedule as early as possible. Thanks Phone #: ###-#### Inspection requested via web by Alan Lusk
rough in ok cover p/s u/g n ok