ELE13-03331
| ELE-Aging Inspection | 7/31/2018 | 7/31/2018 | 8/3/2018 12:54:32 PM | | FAIL |
|
|
been contacted multiple times on need of final inspection
|
ELE18-00849
| Electrical Rough-In | 7/31/2018 | 7/31/2018 | 7/31/2018 2:56:04 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton...all walls complete...ok to cover.. wiring in plenum walls have been sealed off as needed for code
|
ELE18-02849
| Electrical Rough-In | 7/31/2018 | 7/31/2018 | 7/31/2018 1:31:14 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by shane miller... rewiring kitchen new range circuit existing circuits used for oven, micro and kitchen new cans-kit, living rm, and exterior soffit varify junction boxes accesible in cabinets next to fridge-left and right side
|
ELE18-01528
| Final | 7/31/2018 | 7/31/2018 | 7/31/2018 1:06:03 PM | P | FAIL |
|
|
code 5151 Phone #: ###-#### Inspection requested via web by ron spen cer... 1..can trim in master shower shall be rated for damp/wet location..410.10(D) 2..all 120V 15/20A circuits supplying outlets or devices installed in bedroom shall have AFCI protection..210.12(A)...patio light switch in mst bedroom
|
ELE18-02286
| Final | 7/31/2018 | 7/31/2018 | 7/31/2018 1:02:14 PM | P | NR |
|
|
This is for changing out an old panel. It''s in back corner of the garage. I live nearby, please call when you''re on your way and I should be able to meet you there. Thanks ~ Dan Phone #: ###-#### Inspection requested via web by Dan Hilke... ID Power turned power on before perm service inspection scheduled...job completed past 5 pm...temped in service to get power back on...few additional requirements need done before can final multiple branch circuits in panel need to be on 2 pole breaker grounding needs brought up to code-2 rods intersysytem bond needs installed platform will be installed to satisfy highest breaker highth code requirement romex under panel needs fixed to code with outside outlet as well...romex protected from physical damage and exterior outlet needs GFI protection, W/R outlet and inuse H/D cover
|
ELE18-01715
| Final | 7/30/2018 | 7/31/2018 | 7/31/2018 11:07:57 AM | A | PASS |
|
|
Robert Phone #: ###-####...ok to final
|
ELE18-02543
| Electrical Rough-In | 7/31/2018 | 7/31/2018 | 7/31/2018 11:06:38 AM | P | CANC |
|
|
Overhead inspection please. Thank you. Have a bless day! >> Inspection requested via web by Kyle Lott Inspection cancelled from web by: Kyle Lott
|
ELE18-02875
| Final | 7/31/2018 | 7/31/2018 | 7/31/2018 10:49:47 AM | P | PASS |
|
|
We did not replace the meter base. We ended up just needing to repair the lug. Contact Mike ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates... ID Power replaced meter, unable to look at, no inspection done
|
ELE18-02862
| Rough-In Permanent Service | 7/30/2018 | 7/31/2018 | 7/31/2018 10:44:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn... rough ok to cover p/s u/g new ok
|
ELE18-02881
| Temporary Service | 7/30/2018 | 7/31/2018 | 7/31/2018 10:02:41 AM | A | PASS |
|
|
Please call Lynn prior to arrival at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Lynn Proctor...t/s u/g new ok
|
ELE18-02866
| Final | 7/30/2018 | 7/31/2018 | 7/31/2018 9:47:34 AM | A | PASS |
|
|
Contact at AME is Jeff Dines at ###-####. Phone #: ###-#### Inspection requested via web by A.M.E. Office...OCPD ok to final
|
ELE18-02866
| Electrical Rough-In | 7/31/2018 | 7/31/2018 | 7/31/2018 9:47:04 AM | A | PASS |
|
|
Contact at AME is Jeff Dines at ###-####. Phone #: ###-#### Inspection requested via web by A.M.E. Office...added service outlet and light in attic, new circuit for mini split-thru attic then piped on exterior to disconnect...ok
|
ELE18-02217
| Final | 7/30/2018 | 7/31/2018 | 7/31/2018 9:20:49 AM | A | PASS |
|
|
Thank you. Phone #: ###-#### Inspection requested via web by CHRIS CARMINE...ok to final
|
ELE18-02877
| Electrical Rough-In | 7/30/2018 | 7/31/2018 | 7/31/2018 9:01:15 AM | A | PASS |
|
|
Inspection for Bonding Potting Equal Potential and Underground any questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller... Bonding-4 corners, light, and cover EQ- ring around pool Potting-ok Underground-ok to cover
|
ELE18-01628
| Final | 7/30/2018 | 7/31/2018 | 7/31/2018 8:33:24 AM | A | PASS |
|
|
garage code 8888 Phone #: ###-#### Inspection requested via web by kevin blackmon.. ok to final
|
ELE18-02861
| Rough-In Permanent Service | 7/30/2018 | 7/31/2018 | 7/30/2018 3:11:19 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn Inspection cancelled from web by: Darryn Coburn
|