Inspections for the day of: Tuesday, July 31, 2018.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-03331 ELE-Aging Inspection7/31/20187/31/20188/3/2018 12:54:32 PM FAIL
been contacted multiple times on need of final inspection
ELE18-00849 Electrical Rough-In7/31/20187/31/20187/31/2018 2:56:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton...all walls complete...ok to cover.. wiring in plenum walls have been sealed off as needed for code
ELE18-02849 Electrical Rough-In7/31/20187/31/20187/31/2018 1:31:14 PMPPASS
Phone #: ###-#### Inspection requested via web by shane miller...
rewiring kitchen
new range circuit
existing circuits used for oven, micro and kitchen
new cans-kit, living rm, and exterior soffit
varify junction boxes accesible in cabinets next to fridge-left and right side
ELE18-01528 Final7/31/20187/31/20187/31/2018 1:06:03 PMPFAIL
code 5151 Phone #: ###-#### Inspection requested via web by ron spen cer...
1..can trim in master shower shall be rated for damp/wet location..410.10(D)
2..all 120V 15/20A circuits supplying outlets or devices installed in bedroom shall have AFCI protection..210.12(A)...patio light switch in mst bedroom
ELE18-02286 Final7/31/20187/31/20187/31/2018 1:02:14 PMPNR
This is for changing out an old panel. It''s in back corner of the garage. I live nearby, please call when you''re on your way and I should be able to meet you there. Thanks ~ Dan Phone #: ###-#### Inspection requested via web by Dan Hilke...
ID Power turned power on before perm service inspection scheduled...job completed past 5 pm...temped in service to get power back on...few additional requirements need done before can final
multiple branch circuits in panel need to be on 2 pole breaker
grounding needs brought up to code-2 rods
intersysytem bond needs installed
platform will be installed to satisfy highest breaker highth code requirement
romex under panel needs fixed to code with outside outlet as well...romex protected from physical damage and exterior outlet needs GFI protection, W/R outlet and inuse H/D cover
ELE18-01715 Final7/30/20187/31/20187/31/2018 11:07:57 AMAPASS
Robert Phone #: ###-####...ok to final
ELE18-02543 Electrical Rough-In7/31/20187/31/20187/31/2018 11:06:38 AMPCANC
Overhead inspection please. Thank you. Have a bless day! >> Inspection requested via web by Kyle Lott Inspection cancelled from web by: Kyle Lott
ELE18-02875 Final7/31/20187/31/20187/31/2018 10:49:47 AMPPASS
We did not replace the meter base. We ended up just needing to repair the lug. Contact Mike ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates...
ID Power replaced meter, unable to look at, no inspection done
ELE18-02862 Rough-In Permanent Service7/30/20187/31/20187/31/2018 10:44:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
rough ok to cover
p/s u/g new ok
ELE18-02881 Temporary Service7/30/20187/31/20187/31/2018 10:02:41 AMAPASS
Please call Lynn prior to arrival at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Lynn Proctor...t/s u/g new ok
ELE18-02866 Final7/30/20187/31/20187/31/2018 9:47:34 AMAPASS
Contact at AME is Jeff Dines at ###-####. Phone #: ###-#### Inspection requested via web by A.M.E. Office...OCPD ok to final
ELE18-02866 Electrical Rough-In7/31/20187/31/20187/31/2018 9:47:04 AMAPASS
Contact at AME is Jeff Dines at ###-####. Phone #: ###-#### Inspection requested via web by A.M.E. Office...added service outlet and light in attic, new circuit for mini split-thru attic then piped on exterior to disconnect...ok
ELE18-02217 Final7/30/20187/31/20187/31/2018 9:20:49 AMAPASS
Thank you. Phone #: ###-#### Inspection requested via web by CHRIS CARMINE...ok to final
ELE18-02877 Electrical Rough-In7/30/20187/31/20187/31/2018 9:01:15 AMAPASS
Inspection for Bonding Potting Equal Potential and Underground any questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller...
Bonding-4 corners, light, and cover
EQ- ring around pool
Potting-ok
Underground-ok to cover
ELE18-01628 Final7/30/20187/31/20187/31/2018 8:33:24 AMAPASS
garage code 8888 Phone #: ###-#### Inspection requested via web by kevin blackmon..
ok to final
ELE18-02861 Rough-In Permanent Service7/30/20187/31/20187/30/2018 3:11:19 PMACANC
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn Inspection cancelled from web by: Darryn Coburn