Inspections for the day of: Thursday, July 5, 2007.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01758 Final7/3/20077/5/20077/5/2007 3:33:51 PMPCANC
gena - please call 1/2 hr prior to inspection Phone #: ###-#### called, left message, called contractor, he did not call for inspection, he said he would check on who called and set up an inspection. Homeowner called after 370 out of area and out of time to say they called for inspection. 370 told them that the elect contractor would schedule and call for final.
ELE07-02370 Temporary Service7/5/20077/5/20077/5/2007 3:07:30 PMPPASS
ed; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang correction made, t/s u/g n ok
ELE07-02369 Temporary Service7/5/20077/5/20077/5/2007 2:26:35 PMPPASS
ed; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang corr made, t/s u/g n ok
ELE07-02192 Electrical Rough-In7/5/20077/5/20077/5/2007 1:45:34 PMPPART
ok to cover part of u/g from center area disc to about 20' and from north disc back about 30' with direct burial cable. Will see conduits later
ELE07-02302 Permanent Service7/5/20077/5/20077/5/2007 1:35:38 PMPPASS
CONTACT: STEVE HESS Phone #: ###-#### Internet Inspection Request from: Deb Gooden p/s u/g rec ok ,east side to exst mech shop
ELE07-00886 Final7/3/20077/5/20077/5/2007 12:41:49 PMPPASS
Installed Panel for correction notice Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton correction made, ok to final
ELE07-02377 Rough-In Permanent Service7/3/20077/5/20077/5/2007 10:34:41 AMACANC
glen; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang contr called to cancel
ELE06-02762 Electrical Rough-In7/4/20077/5/20077/5/2007 10:01:04 AMAPASS
This inspection is for an embedded grounding electrode. Phone #: ###-#### Internet Inspection Request from: James Cornwell ok to pour concrete encased electrode, owner augmenting with 2 ground rods
ELE07-02380 Electrical Rough-In7/5/20077/5/20077/5/2007 9:13:21 AMAFAIL
Bonding Grid Underground inspection ###-#### Internet Inspection Request from: Todd Holbrook called, left corr notice, nec 110.3(A) lug shall be suitable for installation and use by listing for purpose, 352.26 there shall not be over 360 degree bends in rnc, 680.10 u/g wiring shall not be within 5' of inside wall of pool
ELE06-03812 Final7/3/20077/5/20077/5/2007 8:35:13 AMAFAIL
chris; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang called contr, left corr notice, BCC shall inspect for ri for u/g and concrete encased electrode at garage, address shall be posted, access shall be provided
ELE07-01601 Electrical Rough-In7/5/20077/5/20077/5/2007 7:58:16 AMAPASS
Grid inspection for cover, wires are secured on both ends. Phone #: ###-#### Internet Inspection Request from: Monty Adkinson corrections made, ok to cover ceiling only