ELE07-01758
| Final | 7/3/2007 | 7/5/2007 | 7/5/2007 3:33:51 PM | P | CANC |
|
|
gena - please call 1/2 hr prior to inspection Phone #: ###-#### called, left message, called contractor, he did not call for inspection, he said he would check on who called and set up an inspection. Homeowner called after 370 out of area and out of time to say they called for inspection. 370 told them that the elect contractor would schedule and call for final.
|
ELE07-02370
| Temporary Service | 7/5/2007 | 7/5/2007 | 7/5/2007 3:07:30 PM | P | PASS |
|
|
ed; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang correction made, t/s u/g n ok
|
ELE07-02369
| Temporary Service | 7/5/2007 | 7/5/2007 | 7/5/2007 2:26:35 PM | P | PASS |
|
|
ed; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang corr made, t/s u/g n ok
|
ELE07-02192
| Electrical Rough-In | 7/5/2007 | 7/5/2007 | 7/5/2007 1:45:34 PM | P | PART |
|
|
ok to cover part of u/g from center area disc to about 20' and from north disc back about 30' with direct burial cable. Will see conduits later
|
ELE07-02302
| Permanent Service | 7/5/2007 | 7/5/2007 | 7/5/2007 1:35:38 PM | P | PASS |
|
|
CONTACT: STEVE HESS Phone #: ###-#### Internet Inspection Request from: Deb Gooden p/s u/g rec ok ,east side to exst mech shop
|
ELE07-00886
| Final | 7/3/2007 | 7/5/2007 | 7/5/2007 12:41:49 PM | P | PASS |
|
|
Installed Panel for correction notice Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton correction made, ok to final
|
ELE07-02377
| Rough-In Permanent Service | 7/3/2007 | 7/5/2007 | 7/5/2007 10:34:41 AM | A | CANC |
|
|
glen; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang contr called to cancel
|
ELE06-02762
| Electrical Rough-In | 7/4/2007 | 7/5/2007 | 7/5/2007 10:01:04 AM | A | PASS |
|
|
This inspection is for an embedded grounding electrode. Phone #: ###-#### Internet Inspection Request from: James Cornwell ok to pour concrete encased electrode, owner augmenting with 2 ground rods
|
ELE07-02380
| Electrical Rough-In | 7/5/2007 | 7/5/2007 | 7/5/2007 9:13:21 AM | A | FAIL |
|
|
Bonding Grid Underground inspection ###-#### Internet Inspection Request from: Todd Holbrook called, left corr notice, nec 110.3(A) lug shall be suitable for installation and use by listing for purpose, 352.26 there shall not be over 360 degree bends in rnc, 680.10 u/g wiring shall not be within 5' of inside wall of pool
|
ELE06-03812
| Final | 7/3/2007 | 7/5/2007 | 7/5/2007 8:35:13 AM | A | FAIL |
|
|
chris; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang called contr, left corr notice, BCC shall inspect for ri for u/g and concrete encased electrode at garage, address shall be posted, access shall be provided
|
ELE07-01601
| Electrical Rough-In | 7/5/2007 | 7/5/2007 | 7/5/2007 7:58:16 AM | A | PASS |
|
|
Grid inspection for cover, wires are secured on both ends. Phone #: ###-#### Internet Inspection Request from: Monty Adkinson corrections made, ok to cover ceiling only
|