PLM18-02813
| Water and/or Sewer | 7/4/2018 | 7/5/2018 | 7/5/2018 3:01:51 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Stan Beus
|
PLM18-02813
| DOC - Permit Finaled | 7/5/2018 | 7/5/2018 | 7/5/2018 3:01:37 PM | P | PASS |
|
|
|
PLM18-02485
| Water and/or Sewer | 7/5/2018 | 7/5/2018 | 7/5/2018 2:59:51 PM | P | PART |
|
|
New waterline Phone #: ###-#### Inspection requested via web by Raul Castanon-Ok to cover inside only.
|
MEC18-02764
| Rough-in | 7/3/2018 | 7/5/2018 | 7/5/2018 2:22:01 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino
|
PLM18-02741
| Groundwork | 7/3/2018 | 7/5/2018 | 7/5/2018 2:07:14 PM | P | PASS |
|
|
JOB # 19798 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM18-02740
| Groundwork | 7/3/2018 | 7/5/2018 | 7/5/2018 2:07:00 PM | P | PASS |
|
|
JOB # 19797 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
MEC18-02937
| Pressure Test | 7/4/2018 | 7/5/2018 | 7/5/2018 2:06:39 PM | P | PASS |
|
|
Inspection requested via web by Gary Reeves-20 lb gas test pass.
|
MEC18-02938
| Pressure Test | 7/4/2018 | 7/5/2018 | 7/5/2018 2:06:14 PM | P | PASS |
|
|
Inspection requested via web by Gary Reeves-20 lb gas test pass.
|
MEC18-02938
| Rough-in | 7/4/2018 | 7/5/2018 | 7/5/2018 2:05:45 PM | P | PASS |
|
|
Inspection requested via web by Gary Reeves
|
MEC18-02937
| Rough-in | 7/4/2018 | 7/5/2018 | 7/5/2018 2:05:31 PM | P | PASS |
|
|
Inspection requested via web by Gary Reeves
|
PLM18-02522
| Plumbing Rough-in | 7/5/2018 | 7/5/2018 | 7/5/2018 1:14:36 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Steve Spence-Water system undersized. Cannot horizontal wet vent a half bath. Missing cleanouts. Missing nailplates & need to test.
|
PLM18-02475
| Plumbing Rough-in | 7/5/2018 | 7/5/2018 | 7/5/2018 12:33:39 PM | P | PART |
|
|
OK to cover kitchen sink wall only.
|
PLM18-02475
| Water and/or Sewer | 7/5/2018 | 7/5/2018 | 7/5/2018 11:34:49 AM | P | CANC |
|
|
|
PLM18-02812
| Plumbing Rough-in | 7/3/2018 | 7/5/2018 | 7/5/2018 11:01:53 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Soubanh Senethavialy
|
PLM18-02803
| Plumbing Rough-in | 7/3/2018 | 7/5/2018 | 7/5/2018 10:52:10 AM | A | PASS |
|
|
please call we will have to let you in . thank you Pat ; Dan Phone #: ###-#### Inspection requested via web by pat batten
|
PLM17-02585
| Final | 7/4/2018 | 7/5/2018 | 7/5/2018 10:19:07 AM | A | PART |
|
|
Room 153 . Note: Ground floor . The only room with no room number on the door. Phone #: ###-#### Inspection requested via web by Joseph Corcoran-Room 153 pass.
|
PLM17-02578
| Final | 7/4/2018 | 7/5/2018 | 7/5/2018 10:18:41 AM | A | PART |
|
|
Room 236 Phone #: ###-#### Inspection requested via web by Joseph Corcoran-Room 236 pass.
|
PLM18-01709
| Groundwork | 7/3/2018 | 7/5/2018 | 7/5/2018 9:35:50 AM | A | PASS |
|
|
IF QUESTIONS CALL GARY @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
PLM18-02811
| Water and/or Sewer | 7/3/2018 | 7/5/2018 | 7/5/2018 9:16:06 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gregg Barney
|
PLM18-02811
| DOC - Permit Finaled | 7/5/2018 | 7/5/2018 | 7/5/2018 9:15:56 AM | P | PASS |
|
|
|
MEC18-03073
| Pressure Test | 7/3/2018 | 7/5/2018 | 7/5/2018 8:57:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tim Petsche-20 lb gas test pass.
|
MEC18-02905
| Pressure Test | 7/3/2018 | 7/5/2018 | 7/5/2018 8:41:25 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino-Gas piping not complete or on test.
|
MEC18-02905
| Rough-in | 7/3/2018 | 7/5/2018 | 7/5/2018 8:40:49 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Debbie Marino-Need insulation shield on b-vent. Need to hook up all bath exhausts. Need to hook up make-up air for kitchen hood.
|
MEC18-02906
| Final | 7/2/2018 | 7/5/2018 | 7/5/2018 8:11:48 AM | A | PASS |
|
|
Kirk- prefers as early as possible Phone #: ###-####
|
PLM18-00605
| Final | 7/5/2018 | 7/5/2018 | 7/5/2018 7:52:55 AM | A | PASS |
|
|
Garage code is 1001. Phone #: ###-#### Inspection requested via web by David Stephenson
|
PLM17-03879
| PLM-Aging Inspection | 7/5/2018 | 7/5/2018 | 7/5/2018 6:21:57 AM | | FAIL |
|
|
No calls
|
PLM17-03772
| PLM-Aging Inspection | 7/5/2018 | 7/5/2018 | 7/5/2018 6:21:11 AM | | PART |
|
|
No calls
|
PLM17-03773
| PLM-Aging Inspection | 7/5/2018 | 7/5/2018 | 7/5/2018 6:20:54 AM | | PART |
|
|
No calls
|