ELE17-02226
| ELE-Aging Inspection | 7/5/2019 | 7/5/2019 | 7/8/2019 3:30:36 PM | | FAIL |
|
|
Sent email to inform of aging permit. Waiting for response.
|
ELE19-00807
| Final | 7/3/2019 | 7/5/2019 | 7/5/2019 10:44:02 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by William Andrews Final ok
|
ELE19-01339
| Final | 7/3/2019 | 7/5/2019 | 7/5/2019 10:43:38 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by William Andrews Final ok
|
ELE19-01425
| Final | 7/3/2019 | 7/5/2019 | 7/5/2019 10:43:17 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by William Andrews 210.8- All 15 or 20 map 120 volt receptacle outlets located with in 6' of a sink shall have GFCI protection. Washer
|
ELE19-01100
| Final | 7/3/2019 | 7/5/2019 | 7/5/2019 9:47:40 AM | A | FAIL |
|
|
garage code 2018 or 2019 Phone #: ###-#### Inspection requested via web by Darryn Coburn 200.9- White conductors used for other than grounded conductors shall be identified other than white at terminals. AC disconnect. 210.70- Each exterior door with grade level access shall have a luminaire installed controlled by a wall switch. Garage man door light no working. House staged unable to test all receptacles.
|