ELE06-02116
| Electrical Rough-In | 7/6/2006 | 7/6/2006 | 7/6/2006 3:42:29 PM | P | PASS |
|
|
need rough in on new building.thank you.; Phone #: ###-#### x Internet Inspection Request from: BRIAN KEITH walls and ceilings ok
|
ELE06-01200
| Final | 7/6/2006 | 7/6/2006 | 7/6/2006 3:02:11 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Zane Robertson ok
|
ELE06-01199
| Final | 7/6/2006 | 7/6/2006 | 7/6/2006 3:01:50 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Zane Robertson ok
|
ELE06-01198
| Final | 7/6/2006 | 7/6/2006 | 7/6/2006 3:01:34 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Zane Robertson ok
|
ELE06-01197
| Final | 7/6/2006 | 7/6/2006 | 7/6/2006 3:01:13 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Zane Robertson ok
|
ELE06-01810
| Permanent Service | 7/5/2006 | 7/6/2006 | 7/6/2006 2:26:26 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Tim Lawrence p/s u/g new ok
|
ELE06-01755
| Rough-In Permanent Service | 6/29/2006 | 7/6/2006 | 7/6/2006 2:07:57 PM | P | PASS |
|
|
DAVE; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s u/g rec. ok for both meters
|
ELE06-02371
| Electrical Rough-In | 7/6/2006 | 7/6/2006 | 7/6/2006 1:07:26 PM | P | FAIL |
|
|
tim- call prior for access - ###-#### Internet Inspection Request from: Barbara Buckley corr. met owner, not all violations made and new ones created, 314.16 box fill, 314.43 nails inside plastic boxes outside recepts, 314.20 boxes still not flush with siding, 300.14 free length of conductor owner cut wires short after Bob's inspection, 110.14 needs devices for all splices just twisted wires note told owner to check all locations for box fill not just one box I found
|
ELE06-02116
| Permanent Service | 7/6/2006 | 7/6/2006 | 7/6/2006 11:53:54 AM | P | PASS |
|
|
need rough in on new building.thank you.; Phone #: ###-#### x Internet Inspection Request from: BRIAN KEITH p/s u/g new ok
|
ELE06-02489
| Rough-In Permanent Service | 7/5/2006 | 7/6/2006 | 7/6/2006 11:13:12 AM | A | PASS |
|
|
rick; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley r/i p/s u/g new ok
|
ELE06-00182
| Electrical Rough-In | 7/5/2006 | 7/6/2006 | 7/6/2006 10:50:34 AM | A | PASS |
|
|
Approval to cover trench; Phone #: ###-#### Internet Inspection Request from: Alan Lusk ok
|
ELE06-00409
| Final | 7/5/2006 | 7/6/2006 | 7/6/2006 10:24:59 AM | A | PART |
|
|
damon; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles t/o ok phone contractor needs high voltage rated wire in cabinet 300.3(C)(1)
|
ELE06-02364
| Electrical Rough-In | 7/5/2006 | 7/6/2006 | 7/6/2006 10:22:28 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 7/5/2006 at 3:46:44 PM. Contact: ###-####. pool & spa bond only no equip. grid
|
ELE06-02493
| Electrical Rough-In | 7/5/2006 | 7/6/2006 | 7/6/2006 9:38:00 AM | A | FAIL |
|
|
wall r/i --shawn ###-#### cell corr. called left message300.4 nail plates & 11/4", 314.16 box fill new plastic cutin and old steel boxes, 314.25(D) needs listed fan boxes, 314.20 boxes shall be flush with combustible material, set back no more than 1/4 in other, 210.52(A) outlet spacing din rm & room north of din. rm 250.148 grd metal boxes, note cable sheath shall extend into box S W bed rm cable for outside recept, check for correct small appliance branch circuits
|
ELE06-01268
| Final | 7/5/2006 | 7/6/2006 | 7/6/2006 9:02:34 AM | A | PART |
|
|
blake or damon at ###-####- call for access prior to insp ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley t/o ok only needs 300 volt rated phone cable in elevator control cabinet 300.3(C)(1) card signed
|