Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-00557 ELE-Aging Inspection7/6/20097/6/20097/7/2009 4:04:02 PM DONE
no activity, suc
ELE09-00505 ELE-Aging Inspection7/6/20097/6/20097/7/2009 4:01:32 PM DONE
see final
ELE09-01115 Electrical Rough-In7/6/20097/6/20097/6/2009 3:50:42 PMPPART
contact Jeremy Thornock Phone #: ###-#### Internet Inspection Request from: Sarah Bastian ok to cover u/g anop, see ele09-01112 for correction notice for service for shelters, no esc this project
ELE09-01113 Electrical Rough-In7/6/20097/6/20097/6/2009 3:37:05 PMPPART
contact Jeremy Thornock Phone #: ###-#### Internet Inspection Request from: Sarah Bastian ok to cover u/g anop, see ele09-01112 for correction notice for service to shelter, no esc this project
ELE09-01112 Electrical Rough-In7/6/20097/6/20097/6/2009 3:34:29 PMPPART
Contact Jeremy Thornock Phone #: ###-#### Internet Inspection Request from: Sarah Bastian u/g ok to cover anop, gave correction notice, Nec 230.2 a building or other structure shall be supplied by only 1 service- this is typical for each shelter, no esc this project
ELE09-01172 Conference7/2/20097/6/20097/6/2009 3:14:29 PMPDONE
home Phone #: ###-#### talked about receptacle spacing, 1 1/4", free length conductor, when to call for inspection, no esc this project
ELE08-02776 Final7/6/20097/6/20097/6/2009 2:35:56 PMPPASS
final on unit 533A only Phone #: ###-#### Internet Inspection Request from: Shawna Gates ok to final, no esc this project, no card to sign
ELE09-00903 Conference7/6/20097/6/20097/6/2009 1:43:51 PMPDONE
Alan please call 15 min before going out Phone #: ###-#### talked about outlet spacing, book, 1 1/4", free length conductor, smoke detectors, no esc this project
ELE09-01040 Conference7/6/20097/6/20097/6/2009 1:01:16 PMPDONE
Bill ###-#### talked about ceiling fan, outlets, adding irrigation pump to permit, smoke detectors,
ELE07-03534 DOC - Permit Expired7/6/20097/6/20097/6/2009 10:18:59 AMPPASS
no activity, ok to doc expire
ELE09-00802 Electrical Rough-In7/2/20097/6/20097/6/2009 10:14:14 AMAFAIL
please call if there any problems or questions. I will be in the area. Phone #: ###-#### Internet Inspection Request from: Scott Kraemer called, left correction notice, NEC 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing member or use steel plates to protect cable, 110.12(B) there shall be no broken or damaged parts-cable, 314.23(E) boxes shall not be supported by racways, no esc this project
ESC07-00153 Aging Inspection7/6/20097/6/20097/6/2009 9:41:34 AM DONE
could not find any sign of activity, or address in vicinity
ELE09-01082 Final7/2/20097/6/20097/6/2009 9:01:28 AMACANC
rod Phone #: ###-#### see conference
ELE09-01082 Conference7/6/20097/6/20097/6/2009 8:51:13 AMADONE
rod Phone #: ###-#### reviewed inspection request process, talked about transitions for dc wiring to piping system, no esc this project
ELE09-01174 Electrical Rough-In7/5/20097/6/20097/6/2009 8:14:25 AMAPASS
Electrical cover inspection for (4) outlet locations in BBQ structure located in the back yard. Thank you! Phone #: ###-#### Internet Inspection Request from: Adam Staigle called, ok to cover bbq area, no esc this project